journal article·2015-03-18Open access

Influence of Implant Surface Topography on Primary Stability in a Standardized Osteoporosis Rabbit Model Study

Hiroshi Oue, Kazuya Doi, Yoshifumi Oki, Yusuke Makihara, Takayasu Kubo, Vittoria Perrotti, Adriano Piattelli, Yasumasa Akagawa, Kazuhiro Tsuga

Abstract

Evaluating primary stability is important to predict the prognosis of dental implant treatment. Primary stability is decreased in a low bone density site such as osteoporosis. However, it is difficult to apply in small animal and the effect of the different implant surface topography for the primary stability at low bone density site has not yet fully been investigated. The purpose of the present study was to evaluate the influence of implant surface topography on primary stability in a standardized osteoporosis animal model. Six rabbits underwent ovariectomy and administrated glucocorticoid to induce an osteoporosis model. Sham-operations were performed in additional six rabbits. Implants with machined or oxidized-surfaces were inserted into the femur epiphyses and insertion torque (IT) and implant stability quotient (ISQ) were measured. In sham model, the IT and ISQ did not differ significantly between the both implant. However, the IT value of oxidized-surface implant was significantly higher than that of the machined implant in the osteoporosis model. Meanwhile, ISQ did not significantly differ between the machined and oxidized-surfaced implants. In conclusion, the IT of implants is higher with rough than with smooth surfaces but that there are no differences in ISQ value between different surfaces in a standardized osteoporosis bone reduced rabbit model.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Advanced Prosthodontics, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8553, Japan

Department of Medical, Oral and Biotechnological Sciences, Chieti-Pescara University, Chieti-Via dei Vestini, 31, Chieti 66100, Italy

Department of Prosthetic Dentistry School of Dentistry, Ohu University, 31-1 sankakudo, Kooriyama, Fukushima 963-8611, Japan

References (24)

Show source-provided references
1. Resonance frequency analysis measurements of implants at placement surgery
2. Survival of immediate implant restoration: A retrospective study through 9-year-observation10.1016/j.jpor.2010.10.004 ↗
3. Cutting torque measurements in conjunction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failures?10.1111/j.1708-8208.2004.tb00022.x ↗
4. Correlation between the bone density recorded by a computerized implant motor and by a histomorphometric analysis: A preliminary in vitro study on bovine ribs10.1111/cid.12121 ↗
5. Histological comparison between implants retrieved from patients with and without osteoporosis10.1016/j.ijom.2007.11.019 ↗
6. Osteoporosis and implant failure: An exploratory case-control study10.1902/jop.2000.71.4.625 ↗
7. Experimental studies on oxidezed implants. A histomorphometrical and biomechanical analysis
8. Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative clinical study using resonance frequency analysis
9. Animal models for osteoporosis10.1023/A:1010067326811 ↗
10. Bone response to machined and resorbable blast material titanium implants: an experimental study in rabbits10.1563/1548-1336(2002)028<0002:BRTMAR>2.3.CO;2 ↗
11. Bone mineral measurements of subchondral and trabecular bone in healthy and osteoporotic rabbits10.1007/s00256-005-0022-z ↗
12. Inorganic polyphosphate adsorbed onto hydroxyapatite for guided bone regeneration: An animal study10.4012/dmj.2013-275 ↗
13. Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption
14. Correlation between implant stability quotient and bone-implant contact: A retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans10.1111/j.1708-8208.2006.00022.x ↗
15. Characterization of a new experimental model of osteoporosis in rabbits10.1007/s00774-007-0797-1 ↗
16. PTH [1-34] enhances bone response around titanium implants in a rabbit model of osteoporosis10.1111/j.1600-0501.2012.02495.x ↗
17. A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading
18. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: A human cadaver study10.1111/j.1708-8208.2008.00095.x ↗
19. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study10.1016/S0901-5027(99)80156-8 ↗
20. Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
21. Bone formation around immediately loaded and submerged dental implants with a modified sandblasted and acid-etched surface after 4 and 8 weeks: A human histologic and histomorphometric analysis
22. On implant surfaces: A review of current knowledge and opinions
23. The influence of fixation in formalin on the measurement of stability of implants using resonance frequency analysis and Periotest M®: A study in a dog10.1016/j.bjoms.2013.02.007 ↗
24. Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone10.1016/j.bjoms.2012.08.009 ↗