Computational Modeling to Predict Fatigue Behavior of NiTi Stents: What Do We Need?
Source abstract
Abstract
NiTi (nickel-titanium) stents are nowadays commonly used for the percutaneous treatment of peripheral arterial disease. However, their effectiveness is still debated in the clinical field. In fact a peculiar cyclic biomechanical environment is created before and after stent implantation, with the risk of device fatigue failure. An accurate study of the device fatigue behavior is of primary importance to ensure a successful stenting procedure. Regulatory authorities recognize the possibility of performing computational analyses instead of experimental tests for the assessment of medical devices. However, confidence in numerical methods is only possible after verification and validation of the models used. For the case of NiTi stents, mechanical properties are strongly dependent on the device dimensions and the whole treatments undergone during manufacturing process. Hence, special attention should be paid to the accuracy of the description of the device geometry and the material properties implementation into the numerical code, as well as to the definition of the fatigue limit. In this paper, a path for setting up an effective numerical model for NiTi stent fatigue assessment is proposed and the results of its application in a specific case study are illustrated.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Peripheral Artery Disease Management · Coronary Interventions and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Milan 20133, Italy
Department of Civil and Environmental Engineering, Politecnico di Milano, Milan 20133, Italy
References (23)
Show source-provided references
1. Inter-society consensus for the management of peripheral arterial disease (TASC II)10.1016/j.jvs.2006.12.037 ↗
2. In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee flexion10.1097/01.RVI.0000220367.62137.E8 ↗
3. Clinical outcomes after percutaneous peripheral intervention for chronic total occlusion of superficial femoral arteries: Comparison between self-expandable nitinol stent and stainless steel stent10.1016/j.jjcc.2009.02.017 ↗
4. Prevalence and clinical impact of stent fracture after femoro-popliteal stenting10.1016/j.jacc.2004.11.026 ↗
5. Treating the diseased superficial femoral artery10.1053/j.tvir.2009.10.005 ↗
6. (2012). ISO 25539-2:2012 Cardiovascular Implants—Endovascular Devices—Part 2: Vascular Stents, ISO.
7. (2010). Non-Clinical Engineering Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems.
8. (2013). ISO 5840-3:2013 Cardiovascular Implants—Cardiac Valve Prostheses—Part 3: Heart valve Substitutes Implanted by Transcatheter Techniques, ISO.
9. Computational modelling of in vitro set-ups for peripheral self-expanding nitinol stents: The importance of stent-wall interaction in the assessment of the fatigue resistance10.1007/s13239-013-0164-4 ↗
10. Realistic finite element-based stent design: The impact of balloon folding10.1016/j.jbiomech.2007.08.014 ↗
11. Hemodynamics and in-stent restenosis: Micro-CT images, histology, and computer simulations10.1007/s10439-011-0355-9 ↗
12. A robust integration-algorithm for a finite-strain shape memory-alloy superelastic model10.1016/S0749-6419(00)00050-4 ↗
13. (2007). ASTM F2516-07 Standard Test Method for Tension Testing of Nickel-Titanium Superelastic Materials, ASTM International.
14. Nitinol fatigue: A review of microstructures and mechanisms10.1007/s11665-011-9864-9 ↗
15. Nitinol fatigue life for variable strain amplitude fatigue10.1007/s11665-012-0387-9 ↗
16. Shrivastava, S. (2003, January 8–10). Fatigue testing of diamond shaped specimens. Medical Device Materials, Proceedings of the Materials & Processes for Medical Devices Conference, Anaheim, CA, USA.
17. Fatigue and durability of nitinol stents10.1016/j.jmbbm.2007.08.001 ↗
18. Russell, S.M., and Pelton, A.R. (May, January 30). Cyclic properties of superelastic nitinol: Design implications. SMST-2000, Proceedings of the International Conference on Shape Memory and Superelastic Technologies, Pacific Grove, CA, USA.
19. Accelerated fatigue testing of stent-like diamond specimens10.1007/s11665-010-9794-y ↗
20. NiTi Stent fatigue in a peripheral human artery subjected to pulsatile and articulation loading10.1007/s11665-011-9881-8 ↗
21. Rotary-bending fatigue characteristics of medical-grade NiTi wire10.1016/j.jmbbm.2013.06.003 ↗
22. The consequences of the mechanical environment of peripheral arteries for NiTi stenting10.1007/s11517-011-0815-2 ↗
23. Fatigue behaviour of nitinol peripheral stents: The role of plaque shape studied with computational structural analyses10.1016/j.medengphy.2014.03.006 ↗