Does Intraoral Scanning at the Subgingival Finish Line Affect the Accuracy of Interim Crowns?
Source abstract
Abstract
This in vitro study evaluated the internal surface trueness and the marginal and internal fit of interim crowns fabricated from intraoral scanner (IOS; i500, MEDIT, Seoul, Republic of Korea) data, considering variations in subgingival finish line depth and the use of gingival retraction. A right maxillary first molar was prepared using a milled ceramic abutment, with subgingival finish line depths set at 0, 0.25, 0.50, 0.75, and 1.00 mm from the gingival crest. All specimens were scanned with an IOS, both with and without gingival retraction. Interim crowns were designed from the scan data and produced via three-dimensional (3D) printing. Internal surface trueness was measured using 3D inspection software (Geomagic Control X version 2022.0.0; 3D Systems, Rock Hill, SC, USA), while marginal and internal fit were assessed with the silicone replica technique. Data were analyzed using the Mann–Whitney U test and Kruskal–Wallis H test (α = 0.05). In the absence of gingival retraction, internal surface trueness and crown fit decreased significantly with increasing finish line depth (p < 0.05). At a 1.00 mm depth without retraction, internal trueness reached 100.1 ± 44.5 µm and marginal fit was 189.1 ± 42.2 µm, both exceeding clinical thresholds. With gingival retraction, trueness and fit remained stable across all depths (p > 0.05). At 1.0 mm depth, trueness was 82.0 ± 61.8 µm and marginal fit was 95.2 ± 22.9 µm, both within clinically acceptable limits. A significant correlation was observed between marginal trueness and overall fit when retraction was not performed (p < 0.05). These results demonstrate that increasing subgingival finish line depth can significantly reduce intraoral scanning accuracy, resulting in suboptimal interim crown adaptation when gingival retraction is omitted. To achieve clinically acceptable internal trueness and marginal fit, gingival displacement with a retraction cord is recommended during intraoral scanning for subgingival prosthesis fabrication.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Dental Science, Graduate School, Kyungpook National University, Daegu 41566, Republic of Korea
Advanced Dental Device Development Institute, Kyungpook National University, Daegu 41566, Republic of Korea
Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu 41566, Republic of Korea
Funding
Korean government · Ministry of Trade, Industry and Energy
References (48)
Show source-provided references
1. Potential of innovative digital technologies and CAD/CAM composites in complex cases with change in the VDO
2. An in vitro comparison of the marginal adaptation accuracy of CAD/CAM restorations using different impression systems10.1111/jopr.12446 ↗
3. Joós-Kovács, G., Vecsei, B., Körmendi, S., Gyarmathy, V.A., Borbély, J., and Hermann, P. (2019). Trueness of CAD/CAM digitization with a desktop scanner—An in vitro study. BMC Oral Health, 19.10.1186/s12903-019-0976-1 ↗
4. Accuracy of digital models obtained by direct and indirect data capturing10.1007/s00784-012-0795-0 ↗
5. Will digital impressions eliminate the current problems with conventional impressions?10.14219/jada.archive.2008.0258 ↗
6. Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: A systematic review10.1007/s00784-021-04157-3 ↗
7. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible10.1016/j.jpor.2018.01.003 ↗
8. Accuracy of digital versus conventional implant impressions10.1111/clr.12375 ↗
9. Joda, T., Zarone, F., and Ferrari, M. (2017). The complete digital workflow in fixed prosthodontics: A systematic review. BMC Oral Health, 17.10.1186/s12903-017-0415-0 ↗
10. Three-dimensional accuracy of digital static interocclusal registration by three intraoral scanner systems10.1111/jopr.12714 ↗
11. Clinical evaluation of the effects of cutting off, overlapping, and rescanning procedures on intraoral scanning accuracy10.1016/j.prosdent.2021.10.017 ↗
12. Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner: An in vitro study10.1016/j.jdent.2021.103690 ↗
13. Clinical study of the influence of ambient light scanning conditions on the accuracy (trueness and precision) of an intraoral scanner10.1111/jopr.13135 ↗
14. Scanning accuracy and scanning area discrepancies of intraoral digital scans acquired at varying scanning distances and angulations among 4 different intraoral scanners10.1016/j.prosdent.2023.01.025 ↗
15. Die spacer thickness reproduction for central incisor crown fabrication with combined computer-aided design and 3D printing technology: An in vitro study10.1016/j.prosdent.2014.11.004 ↗
16. Marginal and internal fit and intaglio surface trueness of temporary crowns fabricated with stereolithography, digital light processing, and milling technology10.11607/ijp.7764 ↗
17. Comparison of intaglio surface adjustment in the oral cavity for lithium disilicate crowns fabricated using different scanners10.1111/jopr.13259 ↗
18. Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques10.1016/j.prosdent.2015.05.007 ↗
19. The estimation of cement film thickness by an in vivo technique10.1038/sj.bdj.4802708 ↗
20. Effect of in vivo crown margin discrepancies on periodontal health10.1016/0022-3913(91)90225-L ↗
21. Effect of restoration quality on periodontal health10.1016/0022-3913(85)90056-3 ↗
22. Evaluation of the marginal and internal discrepancies of CAD-CAM endocrowns with different cavity depths: An in vitro study10.1016/j.prosdent.2016.03.025 ↗
23. Trueness analysis of zirconia crowns fabricated with 3-dimensional printing10.1016/j.prosdent.2018.04.012 ↗
24. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing10.1016/j.prosdent.2020.04.028 ↗
25. Çakmak, G., Cuellar, A.R., Donmez, M.B., Schimmel, M., Abou-Ayash, S., Lu, W.-E., and Yilmaz, B. (2021). Effect of printing layer thickness on the trueness and margin quality of 3D-printed interim dental crowns. Appl. Sci., 11.10.3390/app11199246 ↗
26. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions10.1016/j.prosdent.2015.09.011 ↗
27. Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns10.1016/j.prosdent.2013.12.020 ↗
28. Effect of margin location on crown preparation resistance form10.1016/j.prosdent.2004.09.006 ↗
29. Periodontal considerations determining the design and location of margins in restorative dentistry10.4103/2229-5194.94184 ↗
30. Son, K., Son, Y.T., Lee, J.M., and Lee, K.B. (2021). Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations. Sci. Rep., 11.10.1038/s41598-021-93455-7 ↗
31. Effect of finish line locations of tooth preparation on the accuracy of intraoral scanners
32. Periodontal response to long-term abuse of the gingival attachment by supracrestal amalgam restorations10.1111/j.1600-051X.1989.tb01035.x ↗
33. Interactions between the gingiva and the margin of restorations10.1034/j.1600-051X.2003.01277.x ↗
34. Son, Y.T., Son, K., and Lee, K.B. (2022). Trueness of intraoral scanners according to subgingival depth of abutment for fixed prosthesis. Sci. Rep., 12.10.1038/s41598-022-23498-x ↗
35. Intraoral digital impression technique: A review10.1111/jopr.12218 ↗
36. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method10.1016/j.jdent.2017.12.006 ↗
37. A new method for the evaluation of the accuracy of full-arch digital impressions in vitro10.1007/s00784-015-1626-x ↗
38. Evaluation of the repeatability of digital and conventional impression techniques using a reference model
39. Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation10.1016/j.prosdent.2018.01.035 ↗
40. Effect of finish line location on the marginal and internal fit of crowns fabricated with digital and conventional workflows
41. Correlation between fit and internal surface trueness of three-unit zirconia prostheses fabricated using a CAD/CAM system: In vitro study
42. Imburgia, M., Logozzo, S., Hauschild, U., Veronesi, G., Mangano, C., and Mangano, F.G. (2017). Accuracy of four intraoral scanners in oral implantology: A comparative in vitro study. BMC Oral Health, 17.10.1186/s12903-017-0383-4 ↗
43. Effect of scan pattern and storage on the trueness and precision of four intraoral digital impression systems
44. Evaluation of the effects of scanner type and scanning strategy on the accuracy of digital impressions of preparations for all-ceramic crowns
45. A review of the applications of additive manufacturing technologies used to fabricate metal and ceramic dental restorations
46. Additive manufacturing techniques in prosthodontics: Where do we currently stand? A critical review10.11607/ijp.5079 ↗
47. Impact of soft tissue simulation on the accuracy of digital impressions for edentulous jaws
48. Accuracy of intraoral digital impressions compared to conventional impressions in in-vitro studies: A systematic review