Influence of Drilling Protocol on Primary Implant Stability Depending on Different Bone Qualities and Implant Macro-Designs, Lengths, and Diameters
Source abstract
Abstract
Background: Primary implant stability is a critical factor for successful osseointegration and long-term implant success. This study investigates the impact of drilling protocol modifications on primary stability, considering different bone qualities and implant macro-designs, lengths, and diameters. Material and Methods: Three implant designs—two parallel-walled and one tapered—were tested with diameters ranging from 3.4 to 5.2 mm and lengths from 7.5 to 14.5 mm. Implants were placed in polyurethane foam blocks simulating different bone densities (10, 15, 25, and 35 PCF). A standard drilling protocol was used in all groups, with modifications based on bone quality: overpreparation in dense bone and underpreparation in softer bone. Primary stability was evaluated using insertion torque (IT). The optimal IT range was defined as 25–50 Ncm, based on clinical guidelines for immediate loading. The influence of drilling protocol adaptations on stability parameters was assessed. Results: Insertion torque was primarily influenced by bone density and implant diameter, with implant length playing a minor role. In dense bone (D1, D2), underpreparation improved torque values, especially in smaller implants, while overpreparation reduced them. The highest torques occurred with 5.2 mm implants, sometimes exceeding 80 Ncm. Standard protocols did not consistently achieve optimal torque across implant types. In soft bone (D3), underpreparation—particularly with tapered implants—was modestly beneficial. In very soft bone (D4), none of the protocols reliably reached the desired torque range. Conclusions: Adapting drilling protocols to bone density improves insertion torque, especially with wider implants and in denser bone. Underpreparation is generally more effective than overpreparation. However, in very soft bone, neither implant geometry nor drilling adaptations reliably achieve optimal primary stability, highlighting the need for additional strategies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Bone health and osteoporosis research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, Preclinical Education and Dental Materials Science, University Hospital Bonn, 53111 Bonn, Germany
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
Funding
Open Access Publication Fund of the University of Bonn
References (61)
Show source-provided references
1. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis10.1111/cid.12623 ↗
2. Herrero-Climent, M., Lemos, B.F., Herrero-Climent, F., Falcao, C., Oliveira, H., Herrera, M., Gil, F.J., Rios-Carrasco, B., and Rios-Santos, J.V. (2020). Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study. Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17124436 ↗
3. The split crest technique and dental implants: A systematic review and meta-analysis10.1016/j.ijom.2016.08.017 ↗
4. Effects on primary stability of three different techniques for implant site preparation in synthetic bone models of different densities10.1016/j.bjoms.2016.07.004 ↗
5. Compensating for poor primary implant stability in different bone densities by varying implant geometry: A laboratory study10.1016/j.ijom.2015.08.985 ↗
6. Comparison between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split-mouth clinical trial focusing on implant stability changes during early healing10.1111/cid.12501 ↗
7. Primary Apical Stability of Tapered Implants Through Reduction of Final Drilling Dimensions in Different Bone Density Models: A Biomechanical Study10.1097/ID.0000000000000479 ↗
8. Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study10.1016/S0300-9785(86)80010-2 ↗
9. Does Length, Diameter, or Bone Quality Affect Primary and Secondary Stability in Self-Tapping Dental Implants?10.1016/j.joms.2016.03.011 ↗
10. Resonance frequency analysis-reliability in third generation instruments: Osstell mentor(R)
11. Assessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study
12. Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review10.1111/cid.12565 ↗
13. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis10.1034/j.1600-0501.1996.070308.x ↗
14. Relationship Between Primary/Mechanical and Secondary/Biological Implant Stability10.11607/jomi.19suppl.g1 ↗
15. Mechanisms of endosseous integration
16. Albrektsson, T., Branemark, P.-I., and Zarb, G. (1985). Patient selection and preparation. Tissue Integrated Prosthesis: Osseointegration in Clinical Dentistry, Quintessence Publishing.
17. Assessment of implant cumulative survival rates in sites with different bone density and related prognostic factors: An 8-year retrospective study of 2,684 implants10.11607/jomi.3580 ↗
18. Bone density vs bone quality: What’s a clinician to do?10.3949/ccjm.76a.08041 ↗
19. Effect of drilling dimension on implant placement torque and early osseointegration stages: An experimental study in dogs10.1016/j.joms.2011.08.006 ↗
20. Biomechanical evaluation of undersized drilling on implant biomechanical stability at early implantation times10.1016/j.joms.2012.10.008 ↗
21. Biomechanical, Biologic, and Clinical Outcomes of Undersized Implant Surgical Preparation: A Systematic Review10.11607/jomi.5340 ↗
22. Stoilov, M., Shafaghi, R., Stark, H., Marder, M., Kraus, D., and Enkling, N. (2023). Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols-An In Vitro Analysis. J. Funct. Biomater., 14.10.3390/jfb14090469 ↗
23. Development of a new implant primary stability parameter: Insertion torque revisited10.1111/j.1708-8208.2011.00392.x ↗
24. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
25. Selection criteria for immediate implant placement and immediate loading for single tooth replacement in the maxillary esthetic zone: A systematic review and meta-analysis10.1111/clr.14109 ↗
26. Combined effect of undersized surgical technique and axial compression on the primary implant stability and host bone architecture10.1016/j.sdentj.2020.03.004 ↗
27. Investigating the effect of insertion torque on marginal bone loss around dental implants10.1016/j.jormas.2023.101523 ↗
28. (1997). Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments (Standard No. ASTM F1839).
29. The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks10.1016/j.prosdent.2017.04.012 ↗
30. Comparison of Osteotome and Conventional Drilling Techniques for Primary Implant Stability: An In Vitro Study10.1563/aaid-joi-D-15-00176 ↗
31. Comuzzi, L., Iezzi, G., Piattelli, A., and Tumedei, M. (2019). An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of NanoShort Dental Implants. Polymers, 11.10.3390/polym11061020 ↗
32. Comuzzi, L., Tumedei, M., Romasco, T., Petrini, M., Afrashtehfar, K.I., Inchingolo, F., Piattelli, A., and Di Pietro, N. (2022). Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets. J. Funct. Biomater., 14.10.3390/jfb14010010 ↗
33. Comuzzi, L., Tumedei, M., Di Pietro, N., Romasco, T., Heydari Sheikh Hossein, H., Montesani, L., Inchingolo, F., Piattelli, A., and Covani, U. (2023). A Comparison of Conical and Cylindrical Implants Inserted in an In Vitro Post-Extraction Model Using Low-Density Polyurethane Foam Blocks. Materials, 16.10.20944/preprints202306.0732.v1 ↗
34. Loading protocols for single-implant crowns: A systematic review and meta-analysis10.11607/jomi.2014suppl.g4.1 ↗
35. Immediate rehabilitation of the edentulous mandible with screw type implants: Results after up to 10 years of clinical function10.1111/j.1600-0501.2011.02292.x ↗
36. Correlation between placement torque and survival of single-tooth implants
37. Different loading strategies of dental implants: A Cochrane systematic review of randomised controlled clinical trials
38. Immediate non-occlusal vs. early loading of dental implants in partially edentulous patients: A multicentre randomized clinical trial. Peri-implant bone and soft-tissue levels10.1111/j.1600-0501.2008.01530.x ↗
39. The Effect of Insertion Torque on the Clinical Outcome of Single Implants: A Randomized Clinical Trial10.1111/cid.12337 ↗
40. Longitudinal analysis on the effect of insertion torque on delayed single implants: A 3-year randomized clinical study10.1111/cid.12586 ↗
41. “Compression Necrosis”—A Cause of Concern for Early Implant Failure? Case Report and Review of Literature10.2147/CCIDE.S453798 ↗
42. Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta-analysis10.1111/jcpe.13733 ↗
43. Dental Implants10.1016/j.cden.2017.06.007 ↗
44. How does dental implant macrogeometry affect primary implant stability? A narrative review10.1186/s40729-023-00485-z ↗
45. Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study10.11607/jomi.9967 ↗
46. Insertion Torque of Variable-Thread Tapered Implants in the Posterior Maxilla: A Clinical Study
47. Low Bone Density Predictability of CBCT and Its Relation to Primary Stability of Tapered Implant Design: A Pilot Study10.1563/aaid-joi-D-21-00159 ↗
48. Menini, M., Bagnasco, F., Calimodio, I., Di Tullio, N., Delucchi, F., Baldi, D., and Pera, F. (2020). Influence of Implant Thread Morphology on Primary Stability: A Prospective Clinical Study. Biomed. Res. Int., 2020.10.1155/2020/6974050 ↗
49. A new concept in maxillary implant surgery: The osteotome technique
50. Histomorphometric Comparison of 3 Osteotomy Techniques10.1097/ID.0000000000000767 ↗
51. A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact10.11607/jomi.4817 ↗
52. A Comparative Assessment of Primary Implant Stability Using Osseodensification vs. Conventional Drilling Methods: A Systematic Review
53. The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: A histomorphometric analysis by micro-CT10.1111/j.1600-0501.2011.02390.x ↗
54. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT10.1111/clr.12315 ↗
55. Clinical Considerations of Adapted Drilling Protocol by Bone Quality Perception10.11607/jomi.5881 ↗
56. Gholami, H., Mericske-Stern, R., Joehren, P., and Enkling, N. (2020). Bone Resorption around Self-Tapping Implants in Bone Density Type I-II: 3-Years Results of a Prospective Clinical Study. Int. J. Dent. Oral Health, 6.10.16966/2378-7090.320 ↗
57. Bone Quality and Quantity and Dental Implant Failure: A Systematic Review and Meta-analysis10.11607/ijp.5142 ↗
58. CBCT-based bone quality assessment: Are Hounsfield units applicable?10.1259/dmfr.20140238 ↗
59. Deep learning in periodontology and oral implantology: A scoping review10.1111/jre.13037 ↗
60. Alqutaibi, A.Y., Algabri, R.S., Elawady, D., and Ibrahim, W.I. (2023). Advancements in artificial intelligence algorithms for dental implant identification: A systematic review with meta-analysis. J. Prosthet. Dent.10.1016/j.prosdent.2023.11.027 ↗
61. Development of artificial intelligence model for supporting implant drilling protocol decision making10.2186/jpr.JPR_D_22_00053 ↗