journal article·2025-07-30Open access

Comparison of the Trueness of Complete Dentures Fabricated Using Liquid Crystal Display 3D Printing According to Build Angle and Natural Light Exposure

Haeri Kim, KeunBaDa Son, So-Yeun Kim, Kyu-Bok Lee

Abstract

The dimensional accuracy of the intaglio surface of complete dentures fabricated using liquid crystal display (LCD) three-dimensional (3D) printing might be influenced by the build angle and post-processing storage conditions. This study evaluated the effect of build angle and natural light exposure duration on the intaglio surface trueness of maxillary complete denture bases. Standardized denture base designs (2 mm uniform thickness) were fabricated using an LCD 3D printer (Lilivis Print; Huvitz, Seoul, Republic of Korea) at build angles of 0°, 45°, and 90° (n = 7 per group). All specimens were printed using the same photopolymer resin (Tera Harz Denture; Graphy, Seoul, Republic of Korea) and identical printing parameters, followed by ultrasonic cleaning and ultraviolet post-curing. Specimens were stored under controlled light-emitting diode lighting and exposed to natural light (400–800 lux) for 0, 14, or 30 days. The intaglio surfaces were scanned and superimposed on the original design data, following the International Organization for Standardization 12836. Quantitative assessment included root mean square deviation, mean deviation, and tolerance percentage. Statistical analyses were performed using one-way analysis of variance and paired t-tests (α = 0.05). Build angle and light exposure duration significantly affected surface trueness (p < 0.05). The 90° build angle group exhibited the highest accuracy and dimensional stability, while the 0° group showed the greatest deviations (p < 0.05). These findings underscore the importance of optimizing build orientation and storage conditions in denture 3D printing.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Additive Manufacturing and 3D Printing Technologies · Engineering Technology and Methodologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dental Science, Graduate School, Kyungpook National University, Daegu 41940, Republic of Korea

Advanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu 41940, Republic of Korea

Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu 41940, Republic of Korea

Funding

National Research Foundation of Korea (NRF) · Korean government · Ministry of Trade, Industry and Energy

References (46)

Show source-provided references
1. Effects of post-curing times on the trueness of 3D printed dental inlays made with permanent resins10.1007/s00784-025-06319-z ↗
2. Evaluation of dimensional changes during post-curing of 3D-printed denture bases10.3390/app112110000 ↗
3. A comparison of trueness and precision of 12 3D printers used in dentistry: Build-angle recommendations10.1038/s41405-022-00108-6 ↗
4. Temizci, T., and Kölüş, T. (2024). Effects of printing angle and post-curing time on the color and translucency of 3D-printed temporary restoration. Biomimetics, 9.10.3390/biomimetics9070420 ↗
5. 3D printing in dentistry10.1038/sj.bdj.2015.914 ↗
6. Computer-aided technology for fabricating complete dentures: Systematic review10.1016/S0022-3913(13)60318-2 ↗
7. A review on clinical use of CAD/CAM and 3D printed dentures
8. Patient satisfaction with CAD/CAM 3D-printed complete dentures: A systematic analysis10.3390/healthcare13040388 ↗
9. Anadioti, E., Musharbash, L., Blatz, M.B., Papavasiliou, G., and Kamposiora, P. (2020). 3D printed complete removable dental prostheses: A narrative review. BMC Oral Health, 20.10.1186/s12903-020-01328-8 ↗
10. CAD/CAM complete denture systems and physical properties: A review of the literature10.1111/jopr.13243 ↗
11. Unkovskiy, A., Schmidt, F., Beuer, F., Spintzyk, S., and Kraemer-Fernandez, P. (2021). Stereolithography vs. direct light processing for rapid manufacturing of complete denture bases: An in vitro accuracy analysis. J. Clin. Med., 10.10.3390/jcm10051070 ↗
12. Alqutaibi, A.Y., Aljohani, R., Almuzaini, S., and Alghauli, M.A. (2025). Physical–mechanical properties and accuracy of additively manufactured resin denture bases: Impact of printing orientation. J. Prosthodont. Res., in press.10.2186/jpr.JPR_D_24_00263 ↗
13. Kim, K.W., Kim, S.Y., Kim, S.-A., Jang, H.-W., Lee, K.-W., and Lee, Y.-S. (2024). Four different build angles in 3D-printed complete denture bases: A comparative in vitro study. Appl. Sci., 14.10.20944/preprints202408.2270.v1 ↗
14. Evaluation of the influence of different build angles on the surface characteristics, accuracy, and dimensional stability of the complete denture base printed by digital light processing10.1016/j.heliyon.2024.e24095 ↗
15. (1994). Accuracy (Trueness and Precision) of Measurement Methods and Results—Part 1: General Principles and Definitions (Standard No. ISO 5725-1).
16. Park, G.S., Kim, S.K., Heo, S.J., Koak, J.Y., and Seo, D.G. (2019). Effects of printing parameters on the fit of implant-supported 3D resin prosthetics. Materials, 12.10.3390/ma12162533 ↗
17. García, N., Gómez-Polo, M., Fernández, M., Antonaya-Martín, J.L., Ortega, R., Gómez-Polo, C., Revilla-León, M., and Cascos, R. (2024). Influence of printing angulation on the accuracy (trueness and precision) of the position of implant analogs in 3D models: An in vitro pilot study. Appl. Sci., 14.10.3390/app14072966 ↗
18. Hada, T., Kanazawa, M., Iwaki, M., Arakida, T., Soeda, Y., Katheng, A., Otake, R., and Minakuchi, S. (2020). Effect of printing direction on accuracy of SLA-printed dentures. Materials, 13.10.3390/ma13153405 ↗
19. Trueness and fitting accuracy of maxillary 3D-printed complete dentures10.2186/jpr.JPR_D_20_00240 ↗
20. Comparison of trueness and precision of 3D-printed dental crowns using LCD and DLP technologies
21. Effects of post-curing time on trueness of 3D-printed dental inlays
22. Effects of build orientation and bar addition on accuracy of complete denture base fabricated with digital light projection: An in vitro study10.2186/jpr.JPR_D_22_00245 ↗
23. Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models10.1016/j.ajodo.2020.11.039 ↗
24. Lohfeld, S., Belnap, B., Retrouvey, J.-M., and Walker, M.P. (2024). Effect of model body type and print angle on the accuracy of 3D-printed orthodontic models. Biomimetics, 9.10.20944/preprints202403.0335.v1 ↗
25. 3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications10.1016/j.actbio.2020.12.044 ↗
26. Clinical outcomes and influence of material parameters on the behavior and survival rate of thin and ultrathin occlusal veneers: A systematic review10.2186/jpr.JPR_D_21_00270 ↗
27. Guidelines for reporting pre-clinical in vitro studies on dental materials10.1016/j.jebdp.2012.10.001 ↗
28. Intaglio surface trueness of milled and 3D-printed digital maxillary and mandibular dentures: A clinical study10.1016/j.prosdent.2021.05.003 ↗
29. Comparison of dimensional accuracy of 3D-printed models for clear aligners among various orientation types and hollow types10.1080/27705781.2023.2251191 ↗
30. Effect of print orientation on the dimensional accuracy and cost-effectiveness of rapid-prototyped dental models using a PolyJet photopolymerization printer: An in vitro study10.1016/j.ortho.2024.100902 ↗
31. Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques10.1111/jopr.13075 ↗
32. Effect of build orientation and layer thickness on manufacturing accuracy, printing time, and material consumption of 3D-printed complete denture bases10.1016/j.jdent.2023.104435 ↗
33. The effect of build angle on the tissue surface adaptation of maxillary and mandibular complete denture bases manufactured by digital light processing10.1016/j.prosdent.2018.12.014 ↗
34. Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study10.1016/j.prosdent.2019.12.014 ↗
35. Effect of layer thickness, build angle, and viscosity on the mechanical properties and manufacturing trueness of denture base resin for digital light processing10.1016/j.jdent.2023.104598 ↗
36. Trueness assessment of additively manufactured maxillary complete denture bases produced at different orientations10.1016/j.prosdent.2021.12.025 ↗
37. Reinforcement of 3D-printed resins for denture base by adding aramid fibers: Effect on mechanical, surface, and optical properties
38. The impact of post-processing procedures on the characteristics of additively manufactured resins: A systematic review
39. Kim, J., and Lee, D.H. (2020). Influence of the postcuring process on dimensional accuracy and seating of 3D-printed polymeric fixed prostheses. Biomed. Res. Int., 2020.10.1155/2020/2150182 ↗
40. Shin, S.H., Lee, J.E., Kim, H., Dong, J.H., and Kim, Y.H. (2021). Evaluation of dimensional changes according to aging period and post-curing time of 3D-printed denture base prostheses: An in vitro study. Materials, 14.10.3390/ma14206185 ↗
41. (2015). Dentistry—Digitizing devices for CAD/CAM systems for indirect dental restorations—Test methods for assessing accuracy (Standard No. ISO 12836:2015).
42. Fit accuracy of complete denture base fabricated by CAD/CAM milling and 3D-printing methods10.1055/s-0042-1757211 ↗
43. Dimensional changes of complete dentures fabricated by milled and printed techniques: An in vitro study10.1016/j.prosdent.2021.06.042 ↗
44. A comparative evaluation of retention of record bases fabricated digitally in various types of posterior palatal seal area10.1016/j.jobcr.2024.11.004 ↗
45. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing10.1016/j.prosdent.2018.02.018 ↗
46. Interim complete immediate dentures for a patient wearing removable partial dentures10.1016/S0022-3913(78)80168-1 ↗