journal article·2025-07-16Open access

In-Vitro Assessment of Artificial Tooth Material Wear Behavior Using 3D Wear Analysis

Sıla Yelekçi, Ayben Şentürk, Funda Akaltan

Abstract

Background: Artificial tooth wear impacts prosthesis durability and function; understanding material–antagonist interactions guides clinical choices. Aim: This in-vitro study aimed to assess the wear behavior of isosit and nanohybrid composite resin artificial teeth when opposed to various antagonist materials using 3D volumetric wear analysis. Materials and Methods: Sixty specimens (n = 10 per group) were prepared from two artificial tooth materials and assigned to six antagonist combinations: isosit–isosit, isosit–nanohybrid composite, isosit–porcelain, nanohybrid composite–isosit, nanohybrid composite–nanohybrid composite, and nanohybrid composite–porcelain. Specimens were scanned before and after 600,000 chewing cycles using a structured-light 3D scanner. Volumetric wear was calculated by superimposing pre- and post-test scans. Data were analyzed using two-way ANOVA and Tukey’s HSD test (α = 0.05). Results: Porcelain antagonists produced the highest wear values (p < 0.05). No significant difference was found between isosit and nanohybrid antagonists (p > 0.05). Identical material pairings showed less wear, though differences were not statistically significant. Conclusions: Porcelain as an antagonist increased wear risk. Using identical materials bilaterally, such as isosit–isosit or nanohybrid–nanohybrid, may help reduce artificial tooth wear in removable prostheses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Health and Care Utilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Align Technology, 06500 Ankara, Turkey

Faculty of Dentistry, Prosthetic Dentistry, Ankara University, 06500 Ankara, Turkey

Funding

Scientific Research Projects Coordination Unit of Ankara University

References (41)

Show source-provided references
1. The influence of vertical dimension of occlusion changes on the electroencephalograms of complete denture wearers10.1016/j.jpor.2014.01.003 ↗
2. Wear resistance of a modified polymethyl methacrylate artificial tooth compared to five commercially available artificial tooth materials10.1016/j.prosdent.2015.01.013 ↗
3. Wear of modern denture teeth—A systematic review10.3390/oral2010011 ↗
4. 2D and 3D wear analysis of 3D printed and prefabricated artificial teeth10.1016/j.identj.2022.10.002 ↗
5. In vitro wear resistance of nano-hybrid composite denture teeth10.1111/jopr.12412 ↗
6. Wear behavior of seven artificial resin teeth assessed with three-dimensional measurements10.1016/j.prosdent.2014.04.030 ↗
7. Wear resistance of nano-filled composite resin and feldspathic ceramic artificial teeth10.1016/S0022-3913(08)60262-0 ↗
8. Surface hardness and wear resistance of prefabricated and CAD-CAM milled artificial teeth: A cross-over clinical study10.1111/jopr.13890 ↗
9. A comparative evaluation of wear resistance of three types of artificial acrylic teeth after removing the glaze layer10.4103/1735-3327.351341 ↗
10. Friction and wear behaviors of dental ceramics against natural tooth enamel10.1016/j.jeurceramsoc.2012.03.021 ↗
11. Morphologic and biochemical changes of the masseter muscles induced by occlusal wear: Studies in rat model10.1177/00220345990780111101 ↗
12. Sakaguchi, R.L., and Powers, J.M. (2012). Craig’s Restorative Dental Materials, Mosby Elsevier. [13th ed.].
13. In vitro wear resistance of three types of composite resin denture teeth10.1016/j.prosdent.2005.08.010 ↗
14. In vitro wear of nano-composite denture teeth10.1111/j.1532-849X.2004.04043.x ↗
15. Shock absorbability and hardness of commercially available denture teeth
16. Wear of resin denture teeth by two-body contact10.1016/j.dental.2005.03.009 ↗
17. An in vitro wear study of posterior denture tooth materials on human enamel10.1046/j.1365-2842.2001.00670.x ↗
18. Laboratory wear investigation of resin posterior denture teeth10.1016/0022-3913(92)90590-7 ↗
19. Effects of filler size, water and alcohol on hardness and laboratory wear of dental composites10.1080/00016350410005555 ↗
20. Three-body wear of resin denture teeth with and without nanofillers10.1016/S0022-3913(10)60014-5 ↗
21. Properties of experimental high abrasion resistance plastic teeth10.1002/jbm.820241208 ↗
22. Characterization of hard resin teeth with nanocomposite enamel layer
23. Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material10.1016/S0022-3913(09)60051-2 ↗
24. Wear of ceramic and antagonist—A systematic evaluation of influencing factors in vitro10.1016/j.dental.2007.06.016 ↗
25. A comparison of two-dimensional and three-dimensional measurements of wear in a laboratory investigation10.1016/j.dental.2010.07.001 ↗
26. On evaluation of wear resistance of tooth enamel and dental materials10.1016/j.wear.2005.08.010 ↗
27. Abrasion wear resistance of different artificial teeth opposed to metal and composite antagonists10.1590/S1678-77572009000500019 ↗
28. Wang, R., Zhu, Y., Chen, C., Han, Y., and Zhou, H. (2022). Tooth wear and tribological investigations in dentistry. Appl. Bionics Biomech., 2022.10.1155/2022/2861197 ↗
29. Jin, S., Choi, J.-W., Jeong, C.-M., Huh, J.-B., Lee, S.-H., Lee, H., and Yun, M.-J. (2019). Evaluating the wear of resin teeth by different opposing restorative materials. Materials, 12.10.3390/ma12223684 ↗
30. How to qualify and validate wear simulation devices and methods10.1016/j.dental.2006.02.002 ↗
31. Intra-oral restorative materials wear: Rethinking the current approaches: How to measure wear10.1016/j.dental.2006.02.003 ↗
32. An artificial oral environment for testing dental materials10.1109/10.133228 ↗
33. Contact wear of artificial denture teeth10.1016/j.jpor.2017.11.001 ↗
34. Bite force and oral function in complete denture wearers10.1111/j.1365-2842.1979.tb00403.x ↗
35. Influences on clinical wear of acrylic denture teeth: A pilot study
36. Assessment of wear facets produced by the ACTA wear machine10.1016/j.jdent.2015.12.003 ↗
37. Twelve-month results of a clinical wear study of three artificial tooth materials10.1016/S0022-3913(05)80179-9 ↗
38. Two-body wear of newly introduced nanocomposite teeth and cross-linked four layered acrylic teeth: A comparative in vitro study10.1007/s13191-014-0381-z ↗
39. In vitro wear resistance, hardness and elastic modulus of artificial denture teeth10.4012/dmj.2010-200 ↗
40. In vitro wear rates of three types of commercial denture tooth materials10.1016/0022-3913(87)90154-5 ↗
41. Comparison of the clinical abrasion resistance of six commercially available denture teeth10.1016/S0022-3913(97)70202-6 ↗