The Relationship Between Peri-Implant Marginal Bone Loss and Resonance Frequency Analysis
Source abstract
Abstract
Resonance frequency analysis (RFA) has been used as a diagnostic method to measure implant stability at all stages of healing. In addition to evaluating the status of the peri-implant marginal bone, it can also indicate the most appropriate time to load the implant. This in vitro study aimed to evaluate the efficacy of RFA as a diagnostic method for the detection of peri-implant marginal bone loss (MBL). Forty bone-level Klockner Vega implants were placed in a polyurethane block with elastic properties similar to those of the maxillary bone. The insertion torque and primary implant stability at the time of placement were measured using an RFA device. A circumferential peri-implant defect was created by removing the cortical bone portion in each implant using a trephine. The stability values were measured again using RFA. The stability values measured using RFA were lower after the creation of the circumferential peri-implant defect, indicating a statistically significant decrease in implant stability. The results of the study tend to show a relationship between peri-implant marginal bone loss and modifications in implant stability measured by RFA.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
DENS-ia Research Group, Faculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain
Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain
Faculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain
Department of Surgery, Faculty of Sports and Health Sciences, University of Zaragoza, 22006 Huesca, Spain
References (48)
Show source-provided references
1. A Systematic Review of the Incidence of Biological and Technical Complications in Implant Dentistry Reported in Prospective Longitudinal Studies of at Least 5 Years10.1034/j.1600-051X.29.s3.12.x ↗
2. Implant Survival and Complications. The Third EAO Consensus Conference 201210.1111/j.1600-0501.2012.02557.x ↗
3. Implant Treatment of Patients with Edentulous Jaws: A 20-Year Follow-Up10.1111/j.1708-8208.2007.00081.x ↗
4. Performance of Titanium Alloy Sintered Porous-Surfaced (SPS) Implants Supporting Mandibular Overdentures During a 20-Year Prospective Study10.1111/clr.12043 ↗
5. Evaluation of Survival and Success Rates of Dental Implants Reported in Longitudinal Studies with a Follow-Up Period of at Least 10 Years: A Systematic Review10.1016/j.ijom.2014.10.023 ↗
6. The Long-Term Efficacy of Currently Used Dental Implants: A Review and Proposed Criteria of Success
7. On Behalf of Working Group 4 of the Seventh European Workshop on Periodontology. Periimplant Diseases: Where Are We Now?—Consensus of the Seventh European Workshop on Periodontology10.1111/j.1600-051X.2010.01674.x ↗
8. On behalf of Group D of the European Workshop on Periodontology. Peri-Implant Diseases: Consensus Report of the Sixth European Workshop on Periodontology10.1111/j.1600-051X.2008.01283.x ↗
9. Chatvaratthana, K., Thaworanunta, S., Seriwatanachai, D., and Wongsirichat, N. (2017). Correlation between the Thickness of the Crestal and Buccolingual Cortical Bone at Varying Depths and Implant Stability Quotients. PLoS ONE, 12.10.1371/journal.pone.0190293 ↗
10. Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible10.1155/2013/506968 ↗
11. How Frequent Does Peri-Implantitis Occur? A Systematic Review and Meta-Analysis10.1007/s00784-017-2276-y ↗
12. The Frequency of Peri-Implant Diseases: A Systematic Review and Meta-Analysis10.1902/jop.2012.120592 ↗
13. Prevalences of Peri-Implantitis and Peri-Implant Mucositis: Systematic Review and Meta-Analysis10.1016/j.jdent.2017.04.011 ↗
14. Occurrence of Peri-Implant Diseases and Risk Indicators at the Patient and Implant Levels: A Multilevel Cross-Sectional Study10.1002/JPER.17-0599 ↗
15. Prevalence, Risk Indicators, and Clinical Characteristics of Peri-Implant Mucositis and Peri-Implantitis for an Internal Conical Connection Implant System: A Multicenter Cross-Sectional Study10.1002/JPER.23-0355 ↗
16. Prevalence and Risk Indicators of Peri-Implant Diseases in Spain10.1111/jcpe.13017 ↗
17. Sensitivity of Resonance Frequency Analysis for Detecting Early Implant Failure: A Case-Control Study10.11607/jomi.3357 ↗
18. The Diagnosis of Peri-Implantitis: A Systematic Review on the Predictive Value of Bleeding on Probing10.1111/clr.13127 ↗
19. Probing Depth at Implants and Teeth: An Experimental Study in the Dog10.1111/j.1600-051X.1993.tb00706.x ↗
20. Histologic Probe Penetration in Healthy and Inflamed Peri-Implant Tissues10.1034/j.1600-0501.1994.050401.x ↗
21. Instrument Selection and Application Used to Probe Dental Implants10.11607/jomi.6950 ↗
22. Probing Around Implants and Teeth with Healthy or Inflamed Peri-Implant Mucosa/Gingiva: A Histologic Comparison in Cynomolgus Monkeys (Macaca fascicularis)10.1034/j.1600-0501.2002.130201.x ↗
23. On behalf of Working Group 4 of the VIII European Workshop on Periodontology. Clinical Research on Peri-Implant Diseases: Consensus Report of Working Group 410.1111/j.1600-051X.2011.01837.x ↗
24. Accuracy of Periapical Radiography in Assessing Bone Level in Implants Affected by Peri-Implantitis: A Cross-sectional Study10.1111/jcpe.12491 ↗
25. Christiaens, V., Pauwels, R., Mowafey, B., and Jacobs, R. (2023). Accuracy of Intra-Oral Radiography and Cone Beam Computed Tomography in the Diagnosis of Buccal Bone Loss. J. Imaging, 9.10.3390/jimaging9080164 ↗
26. Biomechanical Evaluation of Dental Implants with Three Different Designs: Removal Torque and Resonance Frequency Analysis in Rabbits10.1016/j.aanat.2014.07.009 ↗
27. Resonance Frequency Assessment of Dental Implant Stability with Various Bone Qualities: A Numerical Approach10.1034/j.1600-0501.2002.130108.x ↗
28. Biomechanical Evaluation of Dental Implants with Different Surfaces: Removal Torque and Resonance Frequency Analysis in Rabbits10.4047/jap.2009.1.2.107 ↗
29. ISQ as a Diagnostic Tool in Implants Affected with Bone Loss: An In Vitro Experimental Study10.11607/jomi.10510 ↗
30. Quantitative Determination of the Stability of the Implant-Tissue Interface Using Resonance Frequency Analysis10.1034/j.1600-0501.1996.070308.x ↗
31. Peri-implantitis10.1111/jcpe.12954 ↗
32. Branemark, P.I., Zarb, G.A., and Albrektsson, T. (1985). Patient selection and preparation. Tissue Integrated Prsotheses: Osseointegration in Clinical Dentistry, Quintessence. [1st ed.].
33. Diagnostic Methods/Parameters to Monitor Peri-Implant Conditions10.1111/prd.12584 ↗
34. Diagnostic Accuracy of the Implant Stability Quotient in Monitoring Progressive Peri-Implant Bone Loss: An Experimental Study in Dogs10.1111/clr.13368 ↗
35. Resonance Frequency Measurements of Implant Stability In Viva. A Cross-Sectional and Longitudinal Study of Resonance Frequency Measurements on Implants in the Edentulous and Partially Dentate Maxilla10.1034/j.1600-0501.1997.080309.x ↗
36. Implant Stability During Initiation and Resolution of Experimental Periimplantitis: An Experimental Study in the Dog10.1111/j.1708-8208.2005.tb00057.x ↗
37. Correlation Between Implant Stability Quotient and Bone-Implant Contact: A Retrospective Histological and Histomorphometrical Study of Seven Titanium Implants Retrieved from Humans10.1111/j.1708-8208.2006.00022.x ↗
38. Influence of Cortical Bone and Implant Design in the Primary Stability of Dental Implants Measured by Two Different Devices of Resonance Frequency Analysis: An In Vitro Study
39. Differences in Implant Stability Associated with Various Methods of Preparation of the Implant Bed: An In Vitro Study10.1016/S0022-3913(12)60092-4 ↗
40. Reliability of 2 Implant Stability Measuring Methods in Assessment of Various Periimplant Bone Loss: An In Vitro Study with the Periotest and Osstell Mentor10.1097/ID.0000000000000000 ↗
41. Relationship Between Dental Implant Stability Determined by Resonance Frequency Analysis Measurements and Peri-Implant Vertical Defects: An In Vitro Study10.1111/j.1365-2842.2007.01840.x ↗
42. Can Resonance Frequency Analysis Detect Narrow Marginal Bone Defects Around Dental Implants? An Ex Vivo Animal Pilot Study10.1111/adj.12536 ↗
43. The Effects of Defect Type and Depth, and Measurement Direction on the Implant Stability Quotient Value10.1563/AAID-JOI-D-13-0031 ↗
44. Primary Stability of Implants with Peri-Implant Bone Defects of Various Widths: An In Vitro Investigation10.5051/jpis.2019.49.1.39 ↗
45. Influence of Defect Depth on Resonance Frequency Analysis and Insertion Torque Values for Implants Placed in Fresh Extraction Sockets: A Human Cadaver Study10.1111/j.1708-8208.2008.00095.x ↗
46. Implant Primary Stability Determined by Resonance Frequency Analysis in Surgically Created Defects: A Pilot Cadaver Study10.1097/ID.0b013e3181fa7f6a ↗
47. Correlation Between Implant Stability Quotient (ISQ) with Clinical and Histological Aspects of Dental Implants Removed for Mobility10.1177/039463200702001s08 ↗
48. Relationship Between Insertion Torque and Resonance Frequency Measurements, Performed by Resonance Frequency Analysis, in Micromobility of Dental Implants: An In Vitro Study10.1097/ID.0000000000000318 ↗