Relationship Between Fracture Toughness and Fracture Mirror in Modern Polymer-Based Dental Composites

Nicoleta Ilie

Abstract

The mechanical behavior of dental composites depends on the sample size and stress configuration. This makes it difficult to extrapolate laboratory data to clinical restorations with significant variations in size and geometry. Intrinsic parameters, such as fracture toughness, are therefore of great importance, even if they are less common and more difficult to measure. The aim of this study was to apply principles of fractography and fracture mechanics to exploit the results obtained from a three-point bending test. The objectives include calculating a material-specific constant, validating the experimental findings, and establishing a correlation with fracture toughness. Forty representative composites with wide variation in filler quantity (65–83% by weight and 46.4–64% by volume), type (compact glasses and pre-polymerized), and composition were examined. Fracture toughness/KIc was evaluated in a notchless triangular prism test. Fracture type, origin, and mirror size were determined on 280 flexural fracture specimens (n = 20). The amount of filler strongly influences all measured parameters, with the effect strength varying in the sequence: mechanical work (ηP2 = 0.995), modulus of elasticity (ηP2 = 0.991), flexural strength (ηP2 = 0.988), fracture toughness (ηP2 = 0.979), and mirror constant (ηP2 = 0.965). Fracture surfaces allowed the delineation of the fracture mirror and the application of fracture mechanics approaches. The mirror constant was derived from the radius of the fracture mirror, measured in the direction of constant stress, using Orr’s equation, and correlates well with KIc (0.81). Larger confidence intervals were observed for the mirror constant data, while for 5 of 14 materials, the mirror constant was overestimated compared to KIc. The overestimation was attributed to the lower refractive index of the urethane methacrylate composition.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Engineering Technology and Methodologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Conservative Dentistry, University Hospital, Ludwig-Maximilians-University, Goethestr. 70, D-80336 Munich, Germany

References (25)

Show source-provided references
1. Comparison between published clinical success of direct resin composite restorations in vital posterior teeth in 1995–2005 and 2006–2016 periods10.1111/adj.12487 ↗
2. Clinical efficacy of resin-based direct posterior restorations and glass-ionomer restorations—An updated meta-analysis of clinical outcome parameters10.1016/j.dental.2021.10.018 ↗
3. Preparation and characterization of mechanical properties of boron nitride nanosheets (BNNSs)-reinforced resin-matrix ceramics for dentistry10.1016/j.dental.2025.05.008 ↗
4. Dasari, S., Kasilingam, T., Bhatt, P., Singh, M.S., and Kumar, S. (2025). RAFT Polymers-Capped Lanthanide-Doped Nanoparticles via “One-Pot” Aminolysis/Thiolate-Grafting. Macromol. Rapid Commun., e00427.10.1002/marc.202500427 ↗
5. The color of natural teeth: A scoping review of In-Vivo studies10.1016/j.jdent.2025.105725 ↗
6. Effectiveness of bioactive resin materials in preventing secondary caries and retention loss in direct posterior restorations: A systematic review and meta-analysis10.1016/j.jdent.2024.105460 ↗
7. Hill, T.J., and Stevens, C.D. (2025). Fracture Toughness of Esthetic Pressed and Milled Restorative Materials. Int. J. Periodontics Restor. Dent., 1–26.10.11607/prd.7739 ↗
8. (2019). Dentistry—Polymer-Based Restorative Materials (Standard No. ISO. 4049:2019).
9. Resin-based composite performance: Are there some things we can't predict?10.1016/j.dental.2012.06.013 ↗
10. Laboratory mechanical parameters of composite resins and their relation to fractures and wear in clinical trials—A systematic review10.1016/j.dental.2016.11.013 ↗
11. Risk Factors for Failure of Direct Restorations in General Dental Practices10.1177/0022034520924390 ↗
12. Comparing four different methods of measuring fracture toughness and its relationship with fractal dimension in a polycrystalline (3Y-TZP) dental ceramic10.1016/j.dental.2025.01.002 ↗
13. Academy of Dental Materials guidance—Resin composites: Part I—Mechanical properties10.1016/j.dental.2017.04.013 ↗
14. Novel fracture toughness test using a notchless triangular prism (NTP) specimen10.1002/(SICI)1097-4636(199608)31:4<457::AID-JBM4>3.0.CO;2-K ↗
15. Guidelines for measuring fracture mirrors10.1002/9781118144152.ch14 ↗
16. Shear bond strength vs interfacial fracture toughness—Adherence to CAD/CAM blocks10.1016/j.dental.2019.10.003 ↗
17. On the shape and size of the fracture zones on glass fracture surfaces10.1080/14786436608211968 ↗
18. LXXV. The moving griffith crack10.1080/14786445108561302 ↗
19. Prediction of fracture energy and flaw size in glasses from measurements of mirror size10.1111/j.1151-2916.1974.tb11377.x ↗
20. Criteria for Crack Branching in Cylindrical Rods: II, Flexure10.1111/j.1151-2916.1987.tb05662.x ↗
21. Fracture stress as related to flaw and fracture mirror sizes10.1111/j.1151-2916.1977.tb15547.x ↗
22. Filler particle size and composite resin classification systems10.1111/j.1365-2842.1992.tb01487.x ↗
23. Wear of nanofilled dental composites at varying filler concentrations10.1002/jbm.b.33212 ↗
24. Multi-scale analysis of the influence of filler shapes on the mechanical performance of resin composites using high resolution nano-CT images10.1016/j.dental.2020.10.030 ↗
25. Ghelbere, R., and Ilie, N. (2023). Validation of the Orr theory in dental resin-based composites: A fractographic approach. J. Mech. Behav. Biomed. Mater., 144.10.1016/j.jmbbm.2023.105982 ↗