Evaluation of Marginal Fit of CAD/CAM Ceramic Crowns and Scanning Time Using Different Intraoral Scanning Systems
Source abstract
Abstract
This study aimed to evaluate the scanning time and marginal fit of CAD/CAM crowns fabricated using different intraoral scanning systems (IOS) (O1—Omnicam 1.0, O2—Omnicam 2.0, PS—Primescan). A standardized, 3D-printed composite resin die with a full-crown tooth preparation was scanned ten times with each IOS, and the scanning time was recorded. Subsequently, lithium disilicate ceramic crowns were designed and milled. The crowns were seated in the die and scanned using micro-computed tomography to assess the marginal fit. Fifty-two measurements were performed for each crown. Data were assessed for homogeneity, and one-way analysis of variance and the Tukey HSD test were performed (α = 0.05). For the analysis of vertical fit categories, the chi-square (Fisher’s exact) test (α = 0.05) was used. The mean vertical fit values were: O1—46.7 ± 16.4 μm, O2—33.8 ± 21.4 μm (p = 0.041), and PS—12.3 ± 6.6 μm (p < 0.001). The vertical fit values were further categorized by percentage and representative specimens were scanned with electron microscopy to evaluate adaptation. The mean scanning times were: O1—37.4 ± 3.1 s; O2—34.8 ± 2.7 s; and PS—27.8 ± 1.9 s. Significant differences were observed in the scanning times and marginal fit values of the CAD/CAM ceramic crowns across the different IOS systems, with PS demonstrating the best results. Improvements in IOS hardware and software significantly influence these outcomes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia 38405-320, Minas Gerais, Brazil
Private Practice, Odontocenter, Pompéu 35640-000, Minas Gerais, Brazil
Department of General Practice, Virginia Commonwealth University School of Dentistry, Richmond, VA 2329-05668, USA
Funding
Research Support Foundation of the State of Minas Gerais (FAPEMIG)
References (49)
Show source-provided references
1. 3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions: Marginal Fit of All-Ceramic Crowns10.1111/jopr.12180 ↗
2. Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques10.4047/jap.2019.11.5.262 ↗
3. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions10.1007/s00784-015-1641-y ↗
4. Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro10.1016/j.adaj.2019.10.022 ↗
5. Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors
6. Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro
7. Intraoral scanning systems—A current overview
8. Does cad software affect the marginal and internal fit of milled full ceramic crowns?10.1590/1807-3107bor-2022.vol36.0042 ↗
9. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique10.1016/j.prosdent.2014.04.028 ↗
10. Influence of scanner, powder application, and adjustments on CAD-CAM crown fit10.1016/j.prosdent.2017.03.024 ↗
11. Predictability of intraoral scanner error for full-arch implant-supported rehabilitation10.1007/s00784-023-05011-4 ↗
12. Does ambient light affect the accuracy and scanning time of intraoral scans?10.1016/j.prosdent.2020.03.021 ↗
13. Recent advances in dental optics—Part I: 3D intraoral scanners for restorative dentistry10.1016/j.optlaseng.2013.07.017 ↗
14. Intraoral Scanner Technologies: A Review to Make a Successful Impression10.1155/2017/8427595 ↗
15. Kim, R.J.Y., Benic, G.I., and Park, J.M. (2021). Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies. Sci. Rep., 11.10.1038/s41598-021-82218-z ↗
16. Accuracy testing of a new intraoral 3D camera
17. Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system10.1016/S0022-3913(10)60128-X ↗
18. Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns10.4047/jap.2010.2.2.33 ↗
19. A rationale for comparison of plaque-retaining properties of crown systems10.1016/0022-3913(89)90329-6 ↗
20. Comparison of digital intraoral scanner reproducibility and image trueness considering repetitive experience10.1016/j.prosdent.2017.05.002 ↗
21. Influence of Tooth Preparation Design on Fitting Accuracy of CAD-CAM Based Restorations10.1111/jerd.12208 ↗
22. Tooth preparations for complete crowns: An art form based on scientific principles10.1067/mpr.2001.114685 ↗
23. Evaluation of marginal and internal fit of ceramic crown copings
24. The estimation of cement film thickness by an in vivo technique10.1038/sj.bdj.4802708 ↗
25. das Neves, F.D., de Almeida Prado Naves Carneiro, T., do Prado, C.J., Prudente, M.S., Zancopé, K., Davi, L.R., Mendonça, G., and Soares, C.J. (2014). Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system. J. Biomed. Opt., 19.10.1117/1.JBO.19.8.088003 ↗
26. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth10.1046/j.1365-2842.1999.00449.x ↗
27. Comparison of marginal fit between CAD-CAM and hot-press lithium disilicate crowns10.1016/j.prosdent.2018.03.035 ↗
28. Comparison of fit of two types of all-ceramic crowns10.1016/0022-3913(88)90098-4 ↗
29. Marginal Gap, Internal Fit, and Fracture Load of Leucite-Reinforced Ceramic Inlays Fabricated by CEREC inLab and Hot-Pressed Techniques: Marginal Adaptation of Machined and Pressed Leucite Ceramic10.1111/j.1532-849X.2011.00745.x ↗
30. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown10.1016/0022-3913(90)90260-J ↗
31. Council Adopts American Dental Association Specification No. 8 (1967). Dental Zinc Phosphate Cement and 11 Agar Impression Material. J. Am. Dent. Assoc., 74, 1565–1573.10.14219/jada.archive.1967.0412 ↗
32. Precision of fit: The Procera AllCeram crown10.1016/S0022-3913(98)70002-2 ↗
33. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations10.1111/j.1365-2842.2005.01446.x ↗
34. Internal and marginal adaptation of pressable and computer-aided design/computer-assisted manufacture onlay restorations
35. Application of replica technique and SEM in accuracy measurement of ceramic crowns10.2478/v10048-012-0016-7 ↗
36. Fit of a New Pressure-Sintered Zirconium Dioxide Coping
37. Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings
38. Di Fiore, A., Zuccon, A., Carraro, F., Basilicata, M., Bollero, P., Bruno, G., and Stellini, E. (2023). Assessment Methods for Marginal and Internal Fit of Partial Crown Restorations: A Systematic Review. J. Clin. Med., 12.10.3390/jcm12155048 ↗
39. Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns10.1016/j.prosdent.2023.03.018 ↗
40. Toma, F.R., Moleriu, L.C., and Porojan, L. (2023). Micro-CT Marginal and Internal Fit Evaluation of CAD/CAM High-Performance Polymer Onlay Restorations. Polymers, 15.10.3390/polym15071715 ↗
41. Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique10.4103/1305-7456.143612 ↗
42. Micro-CT Evaluation of the Marginal and Internal Fit of Crown and Inlay Restorations Fabricated Via Different Digital Scanners belonging to the Same CAD-CAM System10.11607/ijp.6822 ↗
43. Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study10.1111/jopr.13633 ↗
44. Influence of Computer-aided Design/Computer-aided Manufacturing Diamond Bur Wear on Marginal Fit of Two Lithium Disilicate Ceramic Systems10.2341/19-089-L ↗
45. Effect of Software Version on the Accuracy of an Intraoral Scanning Device10.11607/ijp.5781 ↗
46. Time and Accuracy of the CEREC Omnicam Using Two Different Software Programs10.1111/jopr.13368 ↗
47. (1978). Shipbuilding—Welded bulkhead pieces with flanges for steel pipework—PN 6, PN 10 and PN 16 (Standard No. ISO 5625:1978).
48. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing10.1016/S0022-3913(00)70087-4 ↗
49. Gao, W. (2019). X-Ray Computed Tomography for Dimensional Metrology. Metrology. Precision Manufacturing, Springer.10.1007/978-981-10-4912-5 ↗