Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study
Source abstract
Abstract
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts. The first part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5), a 15° access channel with a specially designed zirconia crown (sASC-15) (n = 5), and a 25° access channel with a specially designed zirconia crown (sASC-25) (n = 5). The reverse torque value (RTV) was measured at 0° for each specimen. The second part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5); a 15° access channel with a zirconia crown (ASC-15) (n = 5), and a 25° access channel with a zirconia crown (ASC-25) (n = 5). The manufacturer’s recommended torque was applied to each specimen, and baseline RTV was measured before cyclic loading. Each ASC implant assembly was cyclically loaded at 0 to 40 N with 1 million cycles at 10 Hz. RTV was measured after cyclic loading. Kruskal–Wallis test and Jonckheere–Terpstra test were used for statistical analysis. All specimens were examined under a digital microscope and scanning electron microscope (SEM) to observe the wear of the screw head before and after the whole experiment. A significant difference in the different percentages of straight RTV (sRTV) between the three groups was found (p = 0.027). The angle of ASC to the different percentages of sRTV showed a significant linear trend (p = 0.003). No significant differences were found in RTV difference after cyclic loading among the ASC-0, ASC-15, and ASC-25 groups (p = 0.212). The ASC-25 group had the most serious degree of wear based on a digital microscope and SEM examination. The ASC angle will affect the actual preload acting on a screw: the larger the ASC angle, the smaller the preload. The performance of the angled ASC groups in RTV difference was comparable to that of 0° ASC after cyclic loading.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan
Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan
Center for Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833, Taiwan
Funding
Chang Gung Medical Foundation and Cheng Shiu University
References (42)
Show source-provided references
1. Medium- and long-term survival rates of implant-supported single and partial restorations at a maximum follow-up of 12 years: A Retrospective Study10.11607/ijp.6883 ↗
2. Long-term (10-year) dental implant survival: A systematic review and sensitivity meta-analysis10.1016/j.jdent.2019.03.008 ↗
3. Long term clinical performance of 10871 dental implants with up to 22 years of follow-up: A cohort study in 4247 patients10.1111/cid.12994 ↗
4. Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: A nonlinear finite element analysis10.1016/j.prosdent.2014.06.010 ↗
5. In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis10.1016/j.jds.2020.08.002 ↗
6. Photoelastic stress analysis in screwed and cemented implant-supported dentures with external hexagon implants10.1097/SCS.0b013e3181e1b46e ↗
7. Does residual cement around implant-supported restorations cause peri-implant disease? A retrospective case analysis10.1111/j.1600-0501.2012.02570.x ↗
8. Cemented and screw-retained implant reconstructions: A systematic review of the survival and complication rates10.1111/j.1600-0501.2012.02538.x ↗
9. Dynamic abutment: A method of redirecting screw access for implant-supported restorations: Technical details and a clinical report10.1016/j.prosdent.2014.11.009 ↗
10. Removal torque and force to failure of non-axially tightened implant abutment screws10.1016/j.prosdent.2018.02.014 ↗
11. Abutment screw torque changes with straight and angled screw-access channels10.1016/j.prosdent.2020.01.018 ↗
12. Effect of cyclic loading on reverse torque values of angled screw channel systems10.1016/j.prosdent.2020.12.020 ↗
13. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies10.1111/j.1532-849X.2006.00096.x ↗
14. The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling10.11607/jomi.2727 ↗
15. Relationship between implant preload and screw loosening on implant-supported prostheses10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2 ↗
16. The influence of abutment angulation on screw loosening of implants in the anterior maxilla
17. Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants10.4012/dmj.28.373 ↗
18. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years10.1111/j.1600-0501.2012.02547.x ↗
19. A systematic review of screw- versus cement-retained implant-supported fixed restorations10.1111/jopr.12128 ↗
20. Abutment screw loosening in angulation-correcting implants: An in vitro study10.1016/j.prosdent.2018.03.005 ↗
21. Vinhas, A.S., Aroso, C., Salazar, F., Relvas, M., Braga, A.C., Ríos-Carrasco, B., Gil, J., Rios-Santos, J.V., Fernández-Palacín, A., and Herrero-Climent, M. (2022). In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs. Materials, 15.10.3390/ma15041392 ↗
22. Influence of three types of abutments on preload values before and after cyclic loading with structural analysis by scanning electron microscopy10.11607/jomi.2481 ↗
23. Implant screw mechanics and the settling effect: Overview10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2 ↗
24. Original vs. non-original abutments for screw-retained single implant crowns: An in vitro evaluation of internal fit, mechanical behaviour and screw loosening10.1111/clr.13390 ↗
25. An in vitro analysis of implant screw torque loss with external hex and internal connection implant systems10.1097/01.id.0000245440.09464.48 ↗
26. Effect of screw channel angulation on reverse torque values of dental implant abutment screws10.1111/jopr.13111 ↗
27. Finite element analysis to determine preload10.1016/j.prosdent.2003.09.012 ↗
28. Screw loosening with interchangeable abutments in internally connected implants after cyclic loading
29. Influence of different maintenance times of torque application on the removal torque values to loosen the prosthetic abutment screws of external hexagon implants10.1097/ID.0b013e31829e548d ↗
30. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations10.1590/S1678-77572008000100011 ↗
31. Effects of abutment screw coating on implant preload10.1111/j.1532-849X.2010.00595.x ↗
32. Implant-abutment screw joint preload of 7 hex-top abutment systems
33. Preload from Tightening and Removal Torque10.1007/s11668-019-00693-z ↗
34. The Effect of Torque Application Technique on Screw Preload of Implant-Supported Prostheses10.11607/jomi.4773 ↗
35. Screw loosening of original and non-original abutments in implant dentistry: An in vitro study
36. Dynamic nature of abutment screw retightening: Finite element study of the effect of retightening on the settling effect10.1016/j.prosdent.2014.09.017 ↗
37. Comparison of screw loosening, rotation, and deflection among three implant designs10.1016/S0022-3913(05)80134-9 ↗
38. The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations10.1563/1548-1336(2001)027<0063:TEOIDR>2.3.CO;2 ↗
39. The effect of screwdriver angle variation on the off-axis implant abutment system and hexalobular screw10.1016/j.prosdent.2019.01.008 ↗
40. Angled implant abutments: A practical application of available knowledge10.14219/jada.archive.2011.0057 ↗
41. Influence of off-axis loading of an anterior maxillary implant: A 3-dimensional finite element analysis
42. Influence of abutment angulation on loss of prosthetic abutment torque under mechanical cycling10.1016/j.prosdent.2020.10.010 ↗