journal article·2022-10-09Open access

A Finite Element Investigation on Material and Design Parameters of Ventricular Septal Defect Occluder Devices

Zhuo Zhang, Yan Xiong, Jinpeng Hu, Xuying Guo, Xianchun Xu, Juan Chen, Yunbing Wang, Yu Chen

Abstract

Background and Objective: Ventricular septal defects (VSDs) are the most common form of congenital heart defects. The incidence of VSD accounts for 40% of all congenital heart defects (CHDs). With the development of interventional therapy technology, transcatheter VSD closure was introduced as an alternative to open heart surgery. Clinical trials of VSD occluders have yielded promising results, and with the development of new material technologies, biodegradable materials have been introduced into the application of occluders. At present, the research on the mechanical properties of occluders is focused on experimental and clinical trials, and numerical simulation is still a considerable challenge due to the braided nature of the VSD occluder. Finite element analysis (FEA) has proven to be a valid and efficient method to virtually investigate and optimize the mechanical behavior of minimally invasive devices. The objective of this study is to explore the axial resistive performance through experimental and computational testing, and to present the systematic evaluation of the effect of various material and braid parameters by FEA. Methods: In this study, an experimental test was used to investigate the axial resistive force (ARF) of VSD Nitinol occluders under axial displacement loading (ADL), then the corresponding numerical simulation was developed and compared with the experimental results to verify the effectiveness. Based on the above validation, numerical simulations of VSD occluders with different materials (polydioxanone (PDO) and Nitinol with different austenite moduli) and braid parameters (wire density, wire diameter, and angle between left and right discs) provided a clear presentation of mechanical behaviors that included the maximal axial resistive force (MARF), maximal axial displacement (MAD) and initial axial stiffness (IAS), the stress distribution and the maximum principal strain distribution of the device under ADL. Results: The results showed that: (1) In the experimental testing, the axial resistive force (ARF) of the tested occluder, caused by axial displacement loading (ADL), was recorded and it increased linearly from 0 to 4.91 N before reducing. Subsequent computational testing showed that a similar performance in the ARF was experienced, albeit that the peak value of ARF was smaller. (2) The investigated design parameters of wire density, wire diameter and the angle between the left and right discs demonstrated an effective improvement (7.59%, 9.48%, 1.28%, respectively, for MARF, and 1.28%, 1.80%, 3.07%, respectively, for IAS) for the mechanical performance for Nitinol occluders. (3) The most influencing factor was the material; the performance rose by 30% as the Nitinol austenite modulus (EA) increased by 10,000 MPa. The performance of Nitinol was better than that of PDO for certain wire diameters, and the performance improved more obviously (1.80% for Nitinol and 0.64% for PDO in IAS, 9.48% for Nitinol and 2.00% for PDO in MARF) with the increase in wire diameter. (4) For all of the models, the maximum stresses under ADL were distributed at the edge of the disc on the loaded side of the occluders. Conclusions: The experimental testing presented in the study showed that the mechanical performance of the Nitinol occluder and the MARF prove that it has sufficient ability to resist falling out from its intended placement. This study also represents the first experimentally validated computational model of braided occluders, and provides a perception of the influence of geometrical and material parameters in these systems. The results could further provide meaningful suggestions for the design of biodegradable VSD closure devices and to realize a series of applications for biodegradable materials in VSD.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cardiac Structural Anomalies and Repair · Elasticity and Material Modeling · Congenital heart defects research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Mechanical Engineering, Sichuan University, Chengdu 610000, China

Shanghai Shape Memory Alloy Co., Ltd., Shanghai 200000, China

College of Biomedical Engineering, Sichuan University, Chengdu 610000, China

Department of Applied Mechanics, Sichuan University, Chengdu 610000, China

Funding

National Key R&D Program of China

References (27)

Show source-provided references
1. The incidence of congenital heart disease10.1016/S0735-1097(02)01886-7 ↗
2. Transcatheter closure of congenital perimembranous ventricular septal defect using the Amplatzer duct occluder 210.1017/S1047951117002396 ↗
3. Transcatheter closure of ventricular septal defects10.1161/01.CIR.78.2.361 ↗
4. Polydioxanone-based bio-materials for tissue engineering and drug/gene delivery applications10.1016/j.ejpb.2015.05.024 ↗
5. Design and characterization of PDO biodegradable intravascular stents10.1177/0040517516660893 ↗
6. A Biodegradable Stent with Surface Functionalization of Combined-Therapy Drugs for Colorectal Cancer10.1002/adhm.201801213 ↗
7. Rueangmontree, T., and Khantachawana, A. (2019). Fabrication and Mechanical Property Evaluation of ASD Occluders Made from Shape Memory Alloys. Materials Science Forum, Trans Tech Publications Ltd.10.4028/www.scientific.net/MSF.962.151 ↗
8. Preparation and mechanical performance evaluation of twocomponent fully absorbable occluder
9. Development and preclinical evaluation of a biodegradable ventricular septal defect occluder10.1002/ccd.24580 ↗
10. Transcatheter closure of perimembranous ventricular septal defect with the Amplatzer membranous VSD occluder 2: Initial world experience and one-year follow-up10.1002/ccd.25004 ↗
11. Transcatheter closure of perimembranous ventricular septal defect using Amplatzer ductal occluder10.1002/ccd.24810 ↗
12. Finite Element Modeling and Analysis of Ventricular Septal Defect Occluders
13. Recent developments in next-generation occlusion devices10.1016/j.actbio.2021.04.050 ↗
14. Closure of atrial septal defects with the Amplatzer occlusion device: Preliminary results10.1016/S0735-1097(98)00039-4 ↗
15. Comparison of computational modelling techniques for braided stent analysis10.1080/10255842.2019.1663414 ↗
16. Bio-absorbable cardiovascular implants: Status and prognosis10.1007/s11837-020-04070-2 ↗
17. Thoracic aorta stent grafts design in terms of biomechanical investigations into flexibility10.3934/mbe.2021042 ↗
18. Self-expanding Nitinol stents: Material and design considerations10.1007/s00330-003-2022-5 ↗
19. Computational mechanics of Nitinol stent grafts10.1016/j.jbiomech.2008.05.032 ↗
20. Design and finite element-based fatigue prediction of a new self-expandable percutaneous mitral valve stent10.1016/j.cad.2013.05.003 ↗
21. Comparison of implicit and explicit finite-element methods for the hydroforming process of an automobile lower arm10.1007/s001700200170 ↗
22. A finite element investigation on design parameters of bare and polymer-covered self-expanding wire braided stents10.1016/j.jmbbm.2020.104305 ↗
23. Kurowski, P. (2017). Finite Element Analysis for Design Engineers. Finite Element Analysis for Design Engineers, SAE.10.4271/R-449 ↗
24. Numerical investigations of the mechanical properties of a braided non-vascular stent design using finite element method10.1080/10255842.2013.873420 ↗
25. Analytical methods for braided stents design and comparison with FEA10.1016/j.jmbbm.2021.104560 ↗
26. Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods10.1016/j.jmbbm.2017.08.025 ↗
27. Novel biodegradable polycaprolactone occlusion device combining nanofibrous PLGA/collagen membrane for closure of atrial septal defect (ASD)10.1007/s10439-011-0368-4 ↗