journal article·2023-02-15Open access

Structural Integrity of Anterior Ceramic Resin-Bonded Fixed Partial Denture: A Finite Element Analysis Study

Mas Linda Mohd Osman, Tong Wah Lim, Hung-Chih Chang, Amir Radzi Ab Ghani, James Kit Hon Tsoi, Siti Mariam Ab Ghani

Abstract

This study was conducted as a means to evaluate the stress distribution patterns of anterior ceramic resin-bonded fixed partial dentures derived from different materials and numerous connector designs that had various loading conditions imposed onto them through the utilization of the finite element method. A finite element model was established on the basis of the cone beam computed tomography image of a cantilevered resin-bonded fixed partial denture with a central incisor as an abutment and a lateral incisor as a pontic. Sixteen finite element models representing different conditions were simulated with lithium disilicate and zirconia. Connector height, width, and shape were set as the geometric parameters. Static loads of 100 N, 150 N, and 200 N were applied at 45 degrees to the pontic. The maximum equivalent stress values obtained for all finite element models were compared with the ultimate strengths of their materials. Higher load exhibited greater maximum equivalent stress in both materials, regardless of the connector width and shape. Loadings of 200 N and 150 N that were correspondingly simulated on lithium disilicate prostheses of all shapes and dimensions resulted in connector fractures. On the contrary, loadings of 200 N, 150 N, and 100 N with rectangular-shaped connectors correspondingly simulated on zirconia were able to withstand the loads. However, two of the trapezoidal-shaped zirconia connectors were unable to withstand the loads and resulted in fractures. It can be deduced that material type, shape, and connector dimensions concurrently influenced the integrity of the bridge.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Centre of Restorative Dentistry Studies, Faculty of Dentistry, Universiti Teknologi MARA, Sungai Buloh 47000, Selangor, Malaysia

Division of Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

Department of Biomedical Engineering, Hungkuang University, Taichung City 433304, Taiwan

College of Engineering, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia

Division of Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China

Funding

Universiti Teknologi MARA DUCS

References (50)

Show source-provided references
1. Resin bonded bridges
2. Fifteen-year survival of resin-bonded vs full-coverage fixed dental prostheses10.1016/j.jpor.2019.02.004 ↗
3. Current ceramic materials and systems with clinical recommendations: A systematic review10.1016/S0022-3913(07)60124-3 ↗
4. Tooth structure removal associated with various preparation designs for anterior teethD10.1067/mpr.2002.124094 ↗
5. Dental implants: The last 100 years10.1016/j.joms.2017.08.045 ↗
6. A retrospective comparison of the survival of vital teeth adjacent to single, bounded edentulous spaces rehabilitated using implant-supported, resin-bonded, and conventional fixed dental prostheses10.1016/j.jdent.2021.103911 ↗
7. Single tooth implant versus resin-bonded bridge: A study of patient’s satisfaction10.4103/ejgd.ejgd_63_20 ↗
8. Five year success rate of resin-bonded fixed partial dentures: A systematic review10.1111/jerd.12431 ↗
9. Critical review about two myths in fixed dental prostheses: Full-Coverage vs. Resin-Bonded, non-Cantilever vs. Cantilever10.1016/j.jdsr.2020.12.002 ↗
10. Attachment of a splint to enamel of lower anterior teeth10.1016/0022-3913(73)90163-7 ↗
11. A prospective study of cantilever resin-bonded bridges: An initial report10.1111/j.1834-7819.2000.tb00239.x ↗
12. The clinical performance of cantilevered resin-bonded bridgework10.1016/0300-5712(95)00073-9 ↗
13. Clinical performance of anterior resin-bonded fixed dental prostheses with different framework designs: A systematic review and meta-analysis10.1016/j.jdent.2016.02.003 ↗
14. Predictability of resin bonded bridges-a systematic review10.1038/sj.bdj.2017.497 ↗
15. Current status on lithium disilicate and zirconia: A narrative review10.1186/s12903-019-0838-x ↗
16. Clinical outcomes of veneered zirconia anterior partial fixed dental prostheses: A 12-year prospective clinical trial
17. 10-year randomized trial (RCT) of zirconia-ceramic and metal-ceramic fixed dental prostheses10.1016/j.jdent.2018.05.015 ↗
18. A review of the success and failure characteristics of resin-bonded bridges10.1038/sj.bdj.2013.686 ↗
19. Survival Rates of Anterior-Region Resin-Bonded Fixed Dental Prostheses: An Integrative Review10.1055/s-0041-1731587 ↗
20. Survival of posterior fixed partial dentures with minimal tooth reduction and improved esthetics: An in vitro study10.1016/j.prosdent.2020.09.047 ↗
21. Mohd Osman, M., Lim, T.W., Ab Ghani, A.R., and Ab Ghani, S.M. (2022, January 24). A Narrative Review on the In-Vitro Performance of Anterior All-Ceramic Resin Bonded Bridges. Proceedings of the 21th Annual Scientific Meeting & 23rd Annual General Meeting IADR Malaysian Section, Selangor, Malaysia.
22. Influence of water storage and thermal cycling on the fracture strength of all-porcelain, resin-bonded fixed partial dentures10.1016/0022-3913(94)90463-4 ↗
23. A retrospective clinical evaluation of two-unit cantilevered resin-bonded fixed partial dentures10.14219/jada.archive.2006.0290 ↗
24. Occlusal force and occlusal contact reestablishment with resin-bonded fixed partial dental prostheses using the Dahl concept: A. clinical study10.1016/j.prosdent.2020.11.035 ↗
25. Occlusal re-establishment and clinical complications of resin-bonded fixed partial dental prostheses cemented at an increased occlusal vertical dimension: A retrospective study10.1016/j.prosdent.2020.06.034 ↗
26. Biomechanical performance of Ti-PEEK dental implants in bone: An in-silico analysis10.1016/j.jmbbm.2022.105422 ↗
27. Elastic Properties of Lithium Disilicate Versus Feldspathic Inlays: Effect on the Bonding by 3D Finite Element Analysis10.1111/jopr.12550 ↗
28. All-ceramic resin-bonded bridges: A3-D finite element analysis study10.1111/j.1600-0722.1996.tb00097.x ↗
29. Three-dimensional finite element analysis of anterior two-unit cantilever resin-bonded fixed dental prostheses10.1155/2015/864389 ↗
30. Factorial analysis of variables influencing mechanical characteristics of a post used to restore a root filled premolar using the finite element stress analysis combined with the Taguchi method10.1111/iej.12499 ↗
31. Biomechanical analysis of the press-fit effect in a conical Morse taper implant system by using an in vitro experimental test and finite element analysis10.1016/j.prosdent.2020.10.022 ↗
32. Biomechanical behavior of adhesive cement layer and periodontal tissues on the restored teeth with zirconia RBFDPs using three-kinds of framework design: 3D FEA study10.1016/j.jpor.2017.10.001 ↗
33. Maximal bite forces in healthy young adults as predicted by surface electromyography10.1016/j.jdent.2004.02.009 ↗
34. Anatomic crown width/length ratios of unworn and worn maxillary teeth in white subjects10.1016/S0022-3913(03)00125-2 ↗
35. Width/length ratios of normal clinical crowns of the maxillary anterior dentition in man10.1034/j.1600-051X.1999.260304.x ↗
36. Can stature be estimated from tooth crown dimensions? A study in a sample of South-East Asians10.1016/j.archoralbio.2016.01.001 ↗
37. Failure of All-ceramic Fixed Partial Dentures in vitro and in vivo: Analysis and Modeling10.1177/00220345950740060301 ↗
38. Biaxial flexural strength and translucent characteristics of dental lithium disilicate glass ceramics with different translucencies10.1016/j.jpor.2019.04.007 ↗
39. A review on translucent zirconia
40. Comparison of optical and crystal properties of three translucent yttria-stabilized tetragonal zirconia polycrystals with those of lithium disilicate glass-ceramic material10.1016/j.jds.2021.01.004 ↗
41. Flexural resistance of heat-pressed and CAD-CAM lithium disilicate with different translucencies
42. Comparison of the mechanical properties of translucent zirconia and lithium disilicate10.1016/j.prosdent.2017.08.004 ↗
43. Influence of connector design on fracture probability of ceramic fixed-partial dentures10.1177/154405910208100909 ↗
44. Survival and complications of zirconia-based fixed dental prostheses: A systematic review10.1016/S0022-3913(12)60051-1 ↗
45. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
46. Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: A three-dimensional finite element analysis10.1016/S0022-3913(10)60012-1 ↗
47. CAD/CAM single retainer zirconia-ceramic resin-bonded fixed dental prostheses: Clinical outcome after 5 years
48. Fifteen-year survival of anterior all-ceramic cantilever resin-bonded fixed dental prostheses10.1016/j.jdent.2016.11.003 ↗
49. Zirconia Ceramic Single-Retainer Resin-Bonded Fixed Dental Prostheses (RBFDPs) after 4 Years of Clinical Service: A Retrospective Clinical and Volumetric Study10.11607/prd.1842 ↗
50. Glass-ceramic resin-bonded fixed partial dentures for replacing a single premolar tooth: A prospective investigation with a 4-year follow-up10.1016/j.prosdent.2019.07.007 ↗