Finite Element Analysis of the Non-Uniform Degradation of Biodegradable Vascular Stents
Source abstract
Abstract
Most of the studies on the finite element analysis (FEA) of biodegradable vascular stents (BVSs) during the degradation process have limited the accuracy of the simulation results due to the application of the uniform degradation model. This paper aims to establish an FEA model for the non-uniform degradation of BVSs by considering factors such as the dynamic changes of the corrosion properties and material properties of the element, as well as the pitting corrosion and stress corrosion. The results revealed that adjusting the corrosion rate according to the number of exposed surfaces of the element and reducing the stress threshold according to the corrosion status accelerates the degradation time of BVSs by 26% and 25%, respectively, compared with the uniform degradation model. The addition of the pitting model reduces the service life of the BVSs by up to 12%. The effective support of the stent to the vessel could reach at least 60% of the treatment effect before the vessel collapsed. These data indicate that the proposed non-uniform degradation model of BVSs with multiple factors produces different phenomena compared with the commonly used models and make the numerical simulation results more consistent with the real degradation scenario.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Magnesium Alloys: Properties and Applications · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
Funding
National Natural Science Foundation of China · Joint Program of Beijing Municipal—Beijing Natural Science Foundation
References (46)
Show source-provided references
1. Canfield, J., and Totary-Jain, H. (2018). 40 years of percutaneous coronary intervention: History and future directions. J. Pers. Med., 8.10.3390/jpm8040033 ↗
2. Influence of plaque calcifications on coronary stent fracture: A numerical fatigue life analysis including cardiac wall movement10.1016/j.jbiomech.2014.01.007 ↗
3. Bioresorbable scaffolds: Current evidence and ongoing clinical trials10.1007/s11886-012-0295-5 ↗
4. Bioresorbable scaffolds: Rationale, current status, challenges, and future10.1093/eurheartj/eht542 ↗
5. Bioresorbable scaffold: The emerging reality and future directions10.1161/CIRCRESAHA.117.310275 ↗
6. Finite element analyses for optimization design of biodegradable magnesium alloy stent10.1016/j.msec.2014.05.078 ↗
7. A numerical corrosion-fatigue model for biodegradable mg alloy stents10.1016/j.actbio.2019.08.004 ↗
8. A review of material degradation modelling for the analysis and design of bioabsorbable stents10.1007/s10439-015-1413-5 ↗
9. Jamari, J., Ammarullah, M.I., Santoso, G., Sugiharto, S., Supriyono, T., and van der Heide, E. (2022). In silico contact pressure of metal-on-metal total hip implant with different materials subjected to gait loading. Metals, 12.10.3390/met12081241 ↗
10. A corrosion model for bioabsorbable metallic stents10.1016/j.actbio.2011.05.032 ↗
11. Optimizing the design of a bioabsorbable metal stent using computer simulation methods10.1016/j.biomaterials.2013.07.010 ↗
12. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels10.1016/j.mseb.2011.03.013 ↗
13. A computational framework to model degradation of biocorrodible metal stents using an implicit finite element solver10.1007/s10439-015-1530-1 ↗
14. Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery10.1093/eurheartj/ehm365 ↗
15. Angiographic and histological assessment of successfully treated late acute stent thrombosis secondary to a sirolimus-eluting stent10.1093/eurheartj/ehl496 ↗
16. Strain-induced accelerated asymmetric spatial degradation of polymeric vascular scaffolds10.1073/pnas.1716420115 ↗
17. A computational modelling of the mechanical performance of a bioabsorbable stent undergoing cyclic loading10.1016/j.prostr.2019.07.013 ↗
18. Continuum damage model for bioresorbable magnesium alloy devices—Application to coronary stents10.1016/j.jmbbm.2010.11.003 ↗
19. A simple model for slow strain rate and constant load corrosion tests of austenitic stainless steel in acid aqueous solution containing sodium chloride10.1016/j.corsci.2008.07.020 ↗
20. Experimental data confirm numerical modeling of the degradation process of magnesium alloys stents10.1016/j.actbio.2012.10.035 ↗
21. A physical corrosion model for bioabsorbable metal stents10.1016/j.actbio.2013.12.059 ↗
22. Flow-induced corrosion behavior of absorbable magnesium-based stents10.1016/j.actbio.2014.08.034 ↗
23. Shape and site dependent in vivo degradation of Mg-Zn pins in rabbit femoral condyle10.3390/ijms15022959 ↗
24. Comparison of the in vivo degradation progress of solid magnesium alloy cylinders and screw-shaped magnesium alloy cylinders in a rabbit model
25. A quantitative study on magnesium alloy stent biodegradation10.1016/j.jbiomech.2018.04.027 ↗
26. A multi-dimensional non-uniform corrosion model for bioabsorbable metallic vascular stents10.1016/j.actbio.2021.07.008 ↗
27. Magnesium: An update on physiological, clinical and analytical aspects10.1016/S0009-8981(99)00258-2 ↗
28. Tzion-Mottye, L.B., Ron, T., Eliezer, D., and Aghion, E. (2022). The effect of Mn on the mechanical properties and in vitro behavior of biodegradable Zn-2%Fe alloy. Metals, 12.10.3390/met12081291 ↗
29. Zinc-based alloys for degradable vascular stent applications10.1016/j.actbio.2018.03.005 ↗
30. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta10.1016/j.biomaterials.2006.05.029 ↗
31. A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials10.1002/jbm.b.31922 ↗
32. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
33. Synthesis, mechanical properties and corrosion behavior of powder metallurgy processed Fe/Mg2Si composites for biodegradable implant applications10.1016/j.msec.2017.07.049 ↗
34. Control of degradation rate of bioabsorbable magnesium by anodization and steam treatment10.1016/j.msec.2010.06.001 ↗
35. Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stentst Adv
36. Jamari, J., Ammarullah, M.I., Santoso, G., Sugiharto, S., Supriyono, T., Prakoso, A.T., Basri, H., and van der Heide, E. (2022). Computational contact pressure prediction of CoCrMo, SS 316L and Ti6Al4V femoral head against UHMWPE acetabular cup under gait cycle. J. Funct. Biomater., 13.10.3390/jfb13020064 ↗
37. Prasadh, S., Raguraman, S., Wong, R., and Gupta, M. (2022). Current status and outlook of temporary implants (Magnesium/Zinc) in cardiovascular applications. Metals, 12.10.3390/met12060999 ↗
38. Zinc-based biomaterials for regeneration and therapy10.1016/j.tibtech.2018.10.009 ↗
39. Current status and perspectives of zinc-based absorbable alloys for biomedical applications10.1016/j.actbio.2019.07.034 ↗
40. Development of biodegradable Zn-1X binary alloys with nutrient alloying elements Mg, Ca and Sr10.1038/srep10719 ↗
41. A critical review of the stress corrosion cracking (SCC) of magnesium alloys10.1002/adem.200500071 ↗
42. Finite element analysis of balloon-expandable coronary stent deployment: Influence of angioplasty balloon configuration10.1002/cnm.2557 ↗
43. Grogan, J.A., Leen, S.B., and Mchugh, P.E. (2010, January 16–19). A Phenomenological Model of Corrosion in Biodegradable Metallic Stents. Proceedings of the ASME 2010 Summer Bioengineering Conference, Naples, FL, USA.10.1115/SBC2010-19361 ↗
44. Meso-scale numerical investigation on cracking of cover concrete induced by corrosion of reinforcing steel10.1016/j.engfailanal.2014.01.011 ↗
45. Investigation on the cracking behavior of concrete cover induced by corner located rebar corrosion10.1016/j.engfailanal.2015.03.019 ↗
46. Investigating the stress corrosion cracking of a biodegradable Zn-0.8 wt%Li alloy in simulated body fluid