journal article·2023-10-12Open access

Biomechanical Analysis of Titanium Dental Implants in the All-on-4 Treatment with Different Implant–Abutment Connections: A Three-Dimensional Finite Element Study

Pei-Shuang Wang, Ming-Hsu Tsai, Yu-Ling Wu, Hung-Shyong Chen, Yao-Ning Lei, Aaron Yu-Jen Wu

Journal of Functional Biomaterials· Volume 14· Issue 10

Abstract

The type of implant-abutment connection is one of the factors influencing the distribution of occlusal forces. This study aims to investigate the biomechanical performance of the mandibular all-on-4 treatment with different implant–abutment connections. Two connection types with 30° abutments and 18-mm implant fixtures were chosen for the posterior implants of the all-on-4 assembly. For the external hexagon connection (EHC) group, the implants with 4 mm in diameter were used. For the internal hexagon connection (IHC) group, we selected implants with 4.3 mm in diameter. A vertical force of 190 N was applied to the cantilever region. The FEA results indicated that the most stressed region in the two groups was prosthetic screws, followed by multi-unit abutments (MUAs). The lowest values of von Mises stress were both observed on the bone. The peak stress value of the implant screw and implant fixture in the EHC group were 37.75% and 33.03% lower than the IHC group, respectively. For stress distribution patterns, the load force tended to be concentrated at locations where components were interconnected. The EHC and IHC are clinically durable under the tested loading conditions, but the prosthetic screws and MUAs can be the weak point on the posterior implant within the mandibular all-on-four assembly. The peak stress values of implant screw and implant fixture in the EHC groups were lower than the IHC group.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dentistry, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung 833, Taiwan

Department of Mechanical Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan

Center for Environmental Toxin and Emerging-Contaminant Research, Cheng Shiu University, Kaohsiung 833, Taiwan

Funding

Chang Gung Medical Foundation and Cheng Shiu University

References (51)

Show source-provided references
1. (2018, January 17). Ministry of Health and Welfare of Taiwan, Available online: https://dep.mohw.gov.tw/DOOH/lp-6553-124.html.
2. (2023, September 25). Centers for Disease Control and Prevention, Available online: https://stacks.cdc.gov/view/cdc/82756/cdc_82756_DS1.pdf.
3. Soboleva, U., and Rogovska, I. (2022). Edentulous Patient Satisfaction with Conventional Complete Dentures. Medicina, 58.10.3390/medicina58030344 ↗
4. Optimum selection of the dental implant diameter and length in the posterior mandible with poor bone quality—A 3D finite element analysis10.1016/j.apm.2010.07.008 ↗
5. “All-on-Four” immediate-function concept with Brånemark system implants for completely edentulous mandibles retrospective clinical study10.1111/j.1708-8208.2003.tb00010.x ↗
6. The All-on-4 treatment concept for the rehabilitation of the completely edentulous mandible: A longitudinal study with 10 to 18 years of follow-up10.1111/cid.12769 ↗
7. Contemporary, ‘All-on-4’ Concept10.1016/j.cden.2014.12.001 ↗
8. The all-on-four treatment concept: Systematic review
9. Analysis of the causes of dental implant fracture: A retrospective clinical study
10. Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections10.3109/00016357.2012.672823 ↗
11. Application of finite element analysis in implant dentistry: A review of the literature10.1067/mpr.2001.115251 ↗
12. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
13. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis10.1016/j.prosdent.2004.07.024 ↗
14. Implant Fracture: A Narrative Literature Review10.3390/prosthesis3040026 ↗
15. Fernández-Asián, I., Martínez-González, Á., Torres-Lagares, D., Serrera-Figallo, M.-Á., and Gutiérrez-Pérez, J.-L. (2019). External Connection versus Internal Connection in Dental Implantology. A Mechanical in vitro Study. Metals, 9.10.3390/met9101106 ↗
16. Evaluation of marginal bone loss of dental implants with internal or external connections and its association with other variables: A systematic review10.1016/j.prosdent.2016.03.027 ↗
17. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
18. Influence of implant connection type on the biomechanical environment of immediately placed implants—CT-based nonlinear, three-dimensional finite element analysis10.1111/j.1708-8208.2009.00155.x ↗
19. Microleakage at the different implant abutment interface: A systematic review
20. Internal vs. external connections for abutments/reconstructions: A systematic review10.1111/j.1600-0501.2012.02556.x ↗
21. Evaluation of internal and external hexagon connections in immediately loaded full-arch rehabilitations: A within-person randomized split-mouth controlled trial with a 3-year follow-up10.1111/cid.13029 ↗
22. The implant neck: Smooth or provided with retention elements: A biomechanical approach10.1034/j.1600-0501.1999.100506.x ↗
23. Wang, Q., Zhang, Z.Z., Bai, S.Z., and Zhang, S.F. (2022). Biomechanical analysis of stress around the tilted implants with different cantilever lengths in all-on-4 concept. BMC Oral Health, 22.10.1186/s12903-022-02520-8 ↗
24. Huang, H.L., Tsai, H.L., Wu, Y.L., Hsu, J.T., and Wu, A.Y. (2022). Biomechanical Evaluation of Bone Atrophy and Implant Length in Four Implants Supporting Mandibular Full-Arch-Fixed Dentures. Materials, 15.10.3390/ma15093295 ↗
25. Wu, A.Y.-J., Hsu, J.-T., Fuh, L.-J., and Huang, H.-L. (2020). Effects of Positions and Angulations of Titanium Dental Implants in Biomechanical Performances in the All-on-Four Treatment: 3D Numerical and Strain Gauge Methods. Metals, 10.10.3390/met10020280 ↗
26. The Comparison of Stress Distribution with Different Implant Numbers and Inclination Angles in All-on-four and Conventional Methods in Maxilla: A Finite Element Analysis10.15171/joddd.2015.044 ↗
27. Finite element stress analysis of the influence of staggered versus straight placement of dental implants
28. A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics10.1111/j.1365-2842.1998.00244.x ↗
29. Two dental implants designed for immediate loading: A finite element analysis
30. Influence of occlusal forces on stress distribution in preloaded dental implant screws10.1016/j.prosdent.2004.01.016 ↗
31. Finite Element Analysis of Screw-Tightening Torque Applied to Custom and Conventional Abutment10.5539/gjhs.v9n9p165 ↗
32. Bone Remodeling Around Implants with External Hexagon and Morse-Taper Connections: A Randomized, Controlled, Split-Mouth, Clinical Trial10.1111/cid.12437 ↗
33. Reasons for failures of oral implants10.1111/joor.12157 ↗
34. Systematic review of the survival rate and incidence of biologic, technical, and esthetic complications of single implant abutments supporting fixed prostheses10.11607/jomi.2014suppl.g2.2 ↗
35. Evaluation of “all-on-four” concept and alternative designs with 3D finite element analysis method10.1111/cid.12024 ↗
36. Finite element analysis on influence of implant surface treatments, connection and bone types10.1016/j.msec.2016.02.061 ↗
37. Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis10.1016/j.jdent.2017.12.001 ↗
38. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis
39. Astra Tech and Brånemark system implants: A 5-year prospective study of marginal bone reactions10.1111/j.1600-0501.2004.01028.x ↗
40. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: A short communication10.1111/j.1365-2842.2006.01545.x ↗
41. Influence of implant connection on the stress distribution in restorations performed with hybrid abutments
42. Stress distribution of two commercial dental implant systems: A three-dimensional finite element analysis10.1016/j.jds.2012.04.006 ↗
43. A finite element analysis of two different dental implants: Stress distribution in the prosthesis, abutment, implant, and supporting bone10.1563/1548-1336(2008)34[1:AFEAOT]2.0.CO;2 ↗
44. Prosthetic and Mechanical Parameters of the Facial Bone under the Load of Different Dental Implant Shapes: A Parametric Study10.3390/prosthesis1010006 ↗
45. Occlusal forces during chewing—Influences of biting strength and food consistency10.1016/0022-3913(81)90247-X ↗
46. Measurement of the Maximum Bite Force in the Natural Dentition with a Gnathodynamometer
47. Forces required by complete dentures for penetrating food in simulated function10.1111/j.1365-2842.1987.tb00757.x ↗
48. A comparative finite element simulation of stress in dental implant–bone interface using isotropic and orthotropic material models in three mastication cycles10.1007/s40430-018-1409-9 ↗
49. Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation10.1007/s12668-019-00649-5 ↗
50. Pietroń, K., Mazurkiewicz, Ł., Sybilski, K., and Małachowski, J. (2022). Correlation of Bone Material Model Using Voxel Mesh and Parametric Optimization. Materials, 15.10.3390/ma15155163 ↗
51. Assessment of mastication with implications for oral rehabilitation: A review10.1111/j.1365-2842.2010.02197.x ↗