journal article·2023-01-06Open access

An Experimental Anodized Titanium Surface for Transgingival Dental Implant Elements—Preliminary Report

Jakub Hadzik, Paweł Kubasiewicz-Ross, Tomasz Gębarowski, Natalia Waloszczyk, Artur Maciej, Agnieszka Stolarczyk, Tomasz Gedrange, Marzena Dominiak, Ernest Szajna, Wojciech Simka

Abstract

The characteristics such as microtopography, physical and chemical properties influence the behavior of an implant in a soft tissue. Anodization—as a potent method of titanium alloy surface modification—of the transgingival abutment or healing screw, has achieved some improvement. One of the possible surface treatment method is low-pressure radiofrequency oxygen plasma treatment. The aim of the study was to evaluate the chemical properties and cytocompatibility of the experimental surface. Titanium discs made of grade-23 titanium alloy (Ti-6Al-4V) anodized (A sample) with different voltage parameters (28, 67, 78, and 98 V) were included in the study. Half of the samples regarded as the “S” group were additionally treated with low-pressure radiofrequency oxygen plasma treatment. The surfaces were characterized using scanning electron microscopy, X-ray spectroscopy and Raman spectroscopy, and electrochemically investigated via a corrosion test. Furthermore, two cell lines were used, including the CHO-compatible reference line and a primary human fibroblast line for the MTT assay; direct (contact) cytotoxicity of the materials was tested with the cells, and the growth of fibroblasts on the surfaces of the different materials was tested. The morphology of the “S”-treated samples did not differ from the morphology of only-anodized samples. However, the oxygen concentration on the surface in that group slightly increased by about 1% as a result of post-trial treatment. The highest corrosion resistance was observed for both A-78 V and S-78 V samples. The cytotoxicity assay revealed no changes in cell morphology or vitality. The MTT test proved comparable culture viability among all groups; however, the “S” samples showed statistically significantly higher fibroblast proliferation and adhesion scores compared to the “A” samples. Through the in vitro study, the low-pressure radiofrequency oxygen plasma treatment of the anodized Ti-6Al-4V alloy presented itself as an auspicious option in the field of transgingival element surface modification of implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Dental Surgery, Faculty of Medicine and Dentistry, Medical University of Wroclaw, 50-425 Wroclaw, Poland

Department of Biostructure and Animal Physiology, Wroclaw University of Environmental and Life Sciences, 51-631 Wroclaw, Poland

Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland

Department of Orthodontics, TU Dresden, 01069 Dresden, Germany

WEA Techlab sp. z o.o., 41-301 Dąbrowa Górnicza, Poland

Funding

Wroclaw University Statutory · National Center for Research and Development, Poland

References (46)

Show source-provided references
1. Makowiecki, A., Hadzik, J., Błaszczyszyn, A., Gedrange, T., and Dominiak, M. (2019). An evaluation of superhydrophilic surfaces of dental implants—A systematic review and meta-analysis. BMC Oral Health, 19.10.1186/s12903-019-0767-8 ↗
2. Roccuzzo, A., Stähli, A., Monje, A., Sculean, A., and Salvi, G.E. (2021). Peri-Implantitis: A Clinical Update on Prevalence and Surgical Treatment Outcomes. J. Clin. Med., 10.10.3390/jcm10051107 ↗
3. Prevalence and risk/protective indicators of peri-implant diseases: A university-representative cross-sectional study10.1111/clr.13684 ↗
4. Zirconia compared to titanium dental implants in preclinical studies—A systematic review and meta-analysis10.1111/clr.13425 ↗
5. Titanium dental implants with different collar design and surface modifications: A systematic review on survival rates and marginal bone levels10.1111/clr.13389 ↗
6. Periimplant diseases: Where are we now?—Consensus of the Seventh European Workshop on Periodontology10.1111/j.1600-051X.2010.01674.x ↗
7. The biological width around implant10.2186/jpr.JPOR_2019_356 ↗
8. Histological evaluation of different abutments in the posterior maxilla and mandible: An experimental study in humans10.1111/jcpe.12115 ↗
9. Differential Behavior of Fibroblasts and Epithelial Cells on Structured Implant Abutment Materials: A Comparison of Materials and Surface Topographies10.1111/cid.12253 ↗
10. Surface thermal oxidation on titanium implants to enhance osteogenic activity and in vivo osseointegration10.1038/srep31769 ↗
11. Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: A randomized controlled histologic study10.1111/clr.12953 ↗
12. Microplasmas, an emerging field of low-temperature plasma science and technology
13. Lupi, S.M., Galinetto, P., Albini, B., Ronza, E.D., Rizzo, S., and Rodriguez y Baena, R. (2020). Micro-Raman Spectroscopy of Dental Implants Subjected to Different Surface Treatments. Appl. Sci., 10.10.3390/app10072417 ↗
14. Benčina, M., Resnik, M., Starič, P., and Junkar, I. (2021). Use of Plasma Technologies for Antibacterial Surface Properties of Metals. Molecules, 26.10.3390/molecules26051418 ↗
15. Tseng, W.Y., Hsu, S.H., Huang, C.H., Tu, Y.C., Tseng, S.C., Chen, H.L., Chen, M.H., Su, W.F., and Lin, L.D. (2013). Low Pressure Radio-Frequency Oxygen Plasma Induced Oxidation of Titanium—Surface Characteristics and Biological Effects. PLoS ONE, 8.10.1371/journal.pone.0084898 ↗
16. Hadzik, J., Kubasiewicz-Ross, P., Simka, W., Gębarowski, T., Barg, E., Cieśla-Niechwiadowicz, A., Szajna, A.T., Szajna, E., Gedrange, T., and Kozakiewicz, M. (2022). Fractal Dimension and Texture Analysis in the Assessment of Experimental Laser-Induced Periodic Surface Structures (LIPSS) Dental Implant Surface-In Vitro Study Preliminary Report. Materials, 15.10.3390/ma15082713 ↗
17. Anodization of titanium in reduced graphene oxide-citric acid electrolyte10.1016/j.rinp.2021.104060 ↗
18. Surface modifications by both anodic oxidation and ion beam implantation on electropolished titanium substrates10.1016/j.apsusc.2019.05.216 ↗
19. A novel titanium implant surface modification by plasma electrolytic oxidation (PEO) preventing tendon adhesion10.1016/j.msec.2021.112030 ↗
20. The black and white coatings on Ti-6Al-4V alloy or pure titanium by plasma electrolytic oxidation in concentrated silicate electrolyte10.1016/j.apsusc.2017.09.109 ↗
21. The effect of plasma treatment on the osseointegration of rough titanium implant: A histo-morphometric study in rabbits10.1016/j.jds.2018.06.002 ↗
22. Minimally invasive flapless implant surgery: A prospective multicenter study10.1111/j.1708-8208.2005.tb00071.x ↗
23. Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance10.1111/cid.12901 ↗
24. Evaluation of the three methods of bacterial decontamination on implants with three different surfaces10.17219/acem/112606 ↗
25. Luengo, F., Solonko, M., Sanz-Esporrín, J., Sanz-Sánchez, I., Herrera, D., and Sanz, M. (2022). Clinical, Microbiological, and Biochemical Impact of the Surgical Treatment of Peri-Implantitis-A Prospective Case Series. J. Clin. Med., 11.10.3390/jcm11164699 ↗
26. Soft-Tissue Management as Part of the Surgical Treatment of Periimplantitis: A Narrative Review10.1097/ID.0000000000000870 ↗
27. Implant Surface Decontamination by Surgical Treatment of Periimplantitis: A Literature Review10.1097/ID.0000000000000840 ↗
28. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: A systematic review and meta-analysis10.1111/clr.12631 ↗
29. Influence of Modified Titanium Abutment Surface on Peri-implant Soft Tissue Behavior: A Systematic Review of In Vitro Studies10.11607/jomi.8110 ↗
30. Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems10.1016/j.aanat.2017.05.008 ↗
31. Role of implant loading time in the prevention of marginal bone loss after implant-supported restorations: A targeted review10.17219/dmp/150111 ↗
32. The effect of metal ions released from different dental implant-abutment couples on osteoblast function and secretion of bone resorbing mediators10.1016/j.jdent.2017.08.002 ↗
33. Soler, M.D., Hsu, S.M., Fares, C., Ren, F., Jenkins, R.J., Gonzaga, L., Clark, A.E., O’neill, E., Neal, D., and Esquivel-Upshaw, J.F. (2020). Titanium Corrosion in Peri-Implantitis. Materials, 13.10.3390/ma13235488 ↗
34. Mijiritsky, E., Ferroni, L., Gardin, C., Peleg, O., Gultekin, A., Saglanmak, A., Delogu, L.G., Mitrecic, D., Piattelli, A., and Tatullo, M. (2020). Presence of ROS in Inflammatory Environment of Peri-Implantitis Tissue: In Vitro and In Vivo Human Evidence. J. Clin. Med., 9.10.3390/jcm9010038 ↗
35. Bressan, E., Ferroni, L., Gardin, C., Bellin, G., Sbricoli, L., Sivolella, S., Brunello, G., Schwartz-Arad, D., Mijiritsky, E., and Penarrocha, M. (2019). Metal Nanoparticles Released from Dental Implant Surfaces: Potential Contribution to Chronic Inflammation and Peri-Implant Bone Loss. Materials, 12.10.3390/ma12122036 ↗
36. Dental implants-associated release of titanium particles: A systematic review10.1111/clr.13372 ↗
37. Corrosion of titanium under simulated inflammation conditions: Clinical context and in vitro investigations10.1016/j.actbio.2021.10.002 ↗
38. Influence of anodized titanium abutments on the esthetics of the peri-implant soft tissue: A clinical study10.1016/j.prosdent.2019.12.023 ↗
39. Farrag, K.M., and Khamis, M.M. (2021). Effect of anodized titanium abutment collars on peri-implant soft tissue: A split-mouth clinical study. J. Prosthet. Dent.
40. Early Response of Fibroblasts and Epithelial Cells to Pink-Shaded Anodized Dental Implant Abutments: An In Vitro Study10.11607/jomi.6479 ↗
41. Attik, N., Phantarasmy, M., Abouelleil, H., Chevalier, C., Barraco, A., Grosgogeat, B., and Lafon, A. (2022). Comparison of the Biological Behavior and Topographical Surface Assessment of a Minimally Invasive Dental Implant and a Standard Implant: An In Vitro Study. Materials, 15.10.3390/ma15217540 ↗
42. Human gingival fibroblast functions are stimulated by oxidized nano-structured titanium surfaces10.1016/j.jdent.2013.07.009 ↗
43. Enhancing the soft-tissue integration of dental implant abutments-in vitro study to reveal an optimized microgroove surface design to maximize spreading and alignment of human gingival fibroblasts10.1002/jbm.b.34836 ↗
44. Effects of ambient oxygen concentration on the growth and antioxidant defenses of of human cell cultures established from fetal and postnatal skin10.1016/S0891-5849(01)00807-3 ↗
45. Carossa, M., Cavagnetto, D., Mancini, F., Mosca Balma, A., and Mussano, F. (2022). Plasma of Argon Treatment of the Implant Surface, Systematic Review of In Vitro Studies. Biomolecules, 12.10.3390/biom12091219 ↗
46. Tsujita, H., Nishizaki, H., Miyake, A., Takao, S., and Komasa, S. (2021). Effect of Plasma Treatment on Titanium Surface on the Tissue Surrounding Implant Material. Int. J. Mol. Sci., 22.10.3390/ijms22136931 ↗