Mechanical Properties of Ti-Nb-Cu Alloys for Dental Machining Applications
Source abstract
Abstract
Titanium has excellent biocompatibility and good corrosion resistance and is extensively used in dental implants and denture bases. However, pure titanium lacks the strength for use in dental prostheses that require relatively high strength. We developed 15 different types of Ti-Nb-Cu alloys and investigated their alloy phases and mechanical properties, including tensile and yield strength, elongation after fracture, and Vickers hardness. The alloy phases of Ti-8%Nb-2%Cu and Ti-13%Nb-2%Cu were α + β, while those of Ti-5%Nb-5%Cu and Ti-10%Nb-5%Cu were α + Ti2Cu. The tensile strength and hardness of these alloys were significantly higher than those of titanium; however, their elongation was less. In particular, the yield strength of these alloys was more than twice that of titanium. These differences in mechanical properties are attributable to solid–solution strengthening and precipitation strengthening. Other compositions with an alloy phase of α + β + Ti2Cu or β + Ti2Cu had high hardness but not high strength. These results suggest that the Ti-8%Nb-2%Cu, Ti-5%Nb-5%Cu, Ti-13%Nb-2%Cu, and Ti-10%Nb-5%Cu alloys can be applied to dental prostheses, which are subject to very high forces from accessories such as long-span bridges, clasps, implant-retained superstructures, and narrow-diameter implants.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Advanced materials and composites · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan
Funding
JSPS KAKENHI
References (41)
Show source-provided references
1. O’Brien, W.J. (2002). Tabulated Values of Physical and Mechanical Properties. Dental Materials and Their Selection, Quintessence Publishing. [3rd ed.].
2. (2016). Dentistry—Metallic Materials for Fixed and Removable Restorations and Appliances (Standard No. ISO 22674).
3. Extra-short (<7mm) and extra-narrow diameter (<3.5mm) implants: A meta-analytic literature review
4. Fatigue failure of narrow implants with different implant-abutment connection designs10.1111/jopr.12540 ↗
5. A critical review of dental implant materials with an emphasis on titanium versus zirconia10.3390/ma8030932 ↗
6. Vanadium: A review of the reproductive and developmental toxicity10.1016/0890-6238(96)00019-6 ↗
7. The neurotoxicity of environmental aluminum is still an issue10.1016/j.neuro.2010.05.009 ↗
8. Machinability evaluation of titanium alloys10.4012/dmj.23.37 ↗
9. Tanzil, S.U., and Saifullah, K. (2017). A study on machinability of Ti6Al4V—Process and optimization. Tech. Rep., 1–21.
10. Titanium alloys and their machinability—A review10.1016/S0924-0136(96)00030-1 ↗
11. Review on machinability of titanium alloys: The process perspective
12. Mechanical properties and grindability of dental cast Ti-Nb alloys10.4012/dmj.22.328 ↗
13. Mechanical properties and microstructures of dental cast Ti-Ag and Ti-Cu alloys10.4012/dmj.21.270 ↗
14. Grindability of dental cast Ti-Ag and Ti-Cu alloys10.4012/dmj.22.191 ↗
15. Mechanical properties and grindability of experimental Ti-Au alloys10.4012/dmj.23.203 ↗
16. Grindability of dental cast Ti-Zr alloys10.2320/matertrans.MRA2008403 ↗
17. Processing and microstructure of Ti-Cu binary alloys: A comprehensive review10.1016/j.pmatsci.2022.100933 ↗
18. Corrosion characteristics of α-ti and Ti2Cu composing Ti-Cu alloys10.4012/dmj.24.610 ↗
19. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti–Cu alloys10.1088/1748-6041/11/6/065001 ↗
20. The antimicrobial activity and characterization of the cast titanium copper alloys with variations of copper content10.1088/1757-899X/547/1/012002 ↗
21. Optimization of mechanical property, antibacterial property and corrosion resistance of Ti-Cu alloy for dental implant10.1016/j.jmst.2019.03.044 ↗
22. Effects of surface roughening on antibacterial and osteogenic properties of Ti-Cu alloys with different Cu contents10.1016/j.jmst.2021.01.067 ↗
23. Antibacterial Ti-Cu alloy with enhanced mechanical properties as implant applications10.1088/2053-1591/abc371 ↗
24. Mechanical properties and microstructures of dental cast Ti-6Nb-4Cu, Ti-18Nb-2Cu, and Ti-24Nb-1Cu alloys10.4012/dmj.2015-354 ↗
25. Takahashi, M., Kikuchi, M., and Takada, Y. (2022). Grindability of Ti-Nb-Cu alloys for dental machining applications. Metals, 12.10.3390/met12050861 ↗
26. Effect of Cu addition on shape memory behavior of Ti-18 mol%Nb alloys10.2320/matertrans.48.414 ↗
27. Microstructure, corrosion and anti-bacterial investigation of novel Ti-xNb-yCu alloy for biomedical implant application10.1016/j.jmrt.2022.04.158 ↗
28. Construction of Ti-Nb-Ti2Cu pseudo-ternary phase diagram10.4012/dmj.2018-394 ↗
29. Forefront of dental application of titanium
30. Phase diagram of the system titanium-copper10.1007/BF00775543 ↗
31. ASM International Alloy Phase Diagram and Handbook Committee (1992). Section 2: Binary Alloy Phase Diagrams. ASM Handbook Volume 3: Alloy Phase Diagrams, ASM Int.
32. The structure and mechanical properties of as-cast Ti–25Nb–xSn alloys for biomedical applications10.1016/j.msea.2013.01.002 ↗
33. Structure and properties of Titanium–25 niobium–x iron alloys10.1023/A:1015798011434 ↗
34. Structure and mechanical properties of as-cast Ti–5Nb–xFe alloys10.1016/j.matchar.2010.05.003 ↗
35. Shape memory properties of Ti–Nb–Mo biomedical alloys10.1016/j.actamat.2010.04.013 ↗
36. Dimple
37. Mechanical properties of cast Ti-6Al-4V-XCu alloys10.1111/j.1365-2842.2004.01347.x ↗
38. Castability and mechanical properties of Ti-6Al-7Nb alloy dental-cast
39. Development of titanium alloys for dental CAD/CAM systems
40. ASM Committee on Titanium and Titanium Alloys (1980). Introduction to Titanium and Its Alloys. Metals Handbook, Properties and Selection: Stainless Steels, Tool Materials and Special-Purpose Metals Vol. 3, ASM Press Int.. [9th ed.].
41. Vickers hardness of cast commercially pure titanium and Ti-6Al-4V alloy submitted to heat treatments10.1590/S0103-64402006000200008 ↗