Comparison between Conventional and Digital Workflow in Implant Prosthetic Rehabilitation: A Randomized Controlled Trial
Source abstract
Abstract
The progress of digital technologies in dental prosthodontics is fast and increasingly accurate, allowing practitioners to simplify their daily work. These technologies aim to substitute conventional techniques progressively, but their real efficiency and predictability are still under debate. Many systematic reviews emphasize the lack of clinical RCTs that compare digital and traditional workflow. To address this evidence, we conducted a three-arm designed clinical RCT, which compares fully digital, combined digital, and analogic and fully analog workflows. We aimed to compare the clinical properties of each workflow regarding interproximal (IC) and occlusal contact (OC), marginal fit, impression time (IT), and patient satisfaction through a VAS scale. In total, 72 patients were included in the study. The IC and OC of the digital workflow were better than the others (p < 0.001), which obtained similar results. No difference between implant–abutment fit was observed (p = 0.5966). The IT was shorter in the digital workflow than the others (p < 0.001), which were similar. Patient satisfaction was higher in the digital workflow than in the conventional one. Despite the limitations, this study’s results support better accuracy and patient tolerance of digital workflow than of conventional techniques, suggesting it as a viable alternative to the latter when performed by clinicians experienced in digital dentistry.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Dental Research and COVID-19
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Interdisciplinary Medicine, ‘Aldo Moro’, University of Bari, 70100 Bari, Italy
Department of Prosthodontics, Magna Graecia Institute, 74121 Taranto, Italy
Department of Medicine and Aging Science, University ‘G. D’annunzio’, 66100 Chieti, Italy
References (38)
Show source-provided references
1. Joda, T., Zarone, F., and Ferrari, M. (2017). The Complete Digital Workflow in Fixed Prosthodontics: A Systematic Review. BMC Oral Health, 17.10.1186/s12903-017-0415-0 ↗
2. Current Techniques for Digital Complete Denture Fabrication
3. The Complete Digital Workflow in Interdisciplinary Dentistry
4. Comparison of Conventional and Digital Workflow for Dental Rehabilitation with a Novel Patient-Specific Framework Implant System: An Experimental Dataset Evaluation10.1186/s40729-022-00405-7 ↗
5. Bernauer, S.A., Zitzmann, N.U., and Joda, T. (2023). The Complete Digital Workflow in Fixed Prosthodontics Updated: A Systematic Review. Healthcare, 11.10.3390/healthcare11050679 ↗
6. Crown Accuracy and Time Efficiency of Cement-Retained Implant-Supported Restorations in a Complete Digital Workflow: A Randomized Control Trial10.1111/jopr.13447 ↗
7. Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial10.1111/jopr.12410 ↗
8. Digital Impressions in Dentistry-Accuracy of Impression Digitalisation by Desktop Scanners10.1007/s00784-019-02995-w ↗
9. Digital vs. Conventional Workflow for One-Abutment One-Time Immediate Restoration in the Esthetic Zone: A Randomized Controlled Trial10.1186/s40729-022-00406-6 ↗
10. Time Efficiency and Efficacy of a Centralized Computer-Aided-Design/Computer-Aided-Manufacturing Workflow for Implant Crown Fabrication: A Prospective Controlled Clinical Study10.1016/j.jdent.2022.104332 ↗
11. Hashemi, A.M., Hashemi, H.M., Siadat, H., Shamshiri, A., Afrashtehfar, K.I., and Alikhasi, M. (2022). Fully Digital versus Conventional Workflows for Fabricating Posterior Three-Unit Implant-Supported Reconstructions: A Prospective Crossover Clinical Trial. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph191811456 ↗
12. Patient Outcomes and Procedure Working Time for Digital versus Conventional Impressions: A Systematic Review10.1016/j.prosdent.2017.07.007 ↗
13. Cicciù, M., Fiorillo, L., D’Amico, C., Gambino, D., Amantia, E.M., Laino, L., Crimi, S., Campagna, P., Bianchi, A., and Herford, A.S. (2020). 3D Digital Impression Systems Compared with Traditional Techniques in Dentistry: A Recent Data Systematic Review. Materials, 13.10.3390/ma13081982 ↗
14. The Influence of Interproximal Contact on Implant-Supported Fixed Partial Dentures in the Posterior Jaw: A Photoelastic Analysis10.1563/AAID-JOI-D-12-00118 ↗
15. Efficiency of Occlusal and Interproximal Adjustments in CAD-CAM Manufactured Single Implant Crowns—Cast-Free vs 3D Printed Cast-Based10.4047/jap.2021.13.6.351 ↗
16. Model-Free Digital Workflow and Immediate Functional Loading of Implant-Supported Monolithic Glass-Ceramic Crowns: A Case Series10.1016/j.jdent.2022.104270 ↗
17. Clinical outcome of single posterior implant-supported monolithic zirconia crowns fabricated using full digital workflow and conventional workflow: A 3-year follow-up
18. Intrasubject Comparison of Digital vs. Conventional Workflow for Screw-Retained Single-Implant Crowns: Prosthodontic and Patient-Centered Outcomes10.1111/clr.13494 ↗
19. Full Arch Digital Scanning Systems Performances for Implant-Supported Fixed Dental Prostheses: A Comparative Study of 8 Intraoral Scanners10.1016/j.jpor.2019.04.002 ↗
20. Quantitative Clinical Adjustment Analysis of Posterior Single Implant Crown in a Chairside Digital Workflow: A Randomized Controlled Trial10.1111/clr.13519 ↗
21. Lerner, H., Mouhyi, J., Admakin, O., and Mangano, F. (2020). Artificial Intelligence in Fixed Implant Prosthodontics: A Retrospective Study of 106 Implant-Supported Monolithic Zirconia Crowns Inserted in the Posterior Jaws of 90 Patients. BMC Oral Health, 20.10.1186/s12903-020-1062-4 ↗
22. Barile, G., De Rosa, G., Papadia, P., Muci, G., Capodiferro, S., and Corsalini, M. (2023). Clinical Comparative Study for Validation of Digital Impression Reliability with the Gypsum Check: A Simple and Fast Way to Evaluate the Trueness and Accuracy of Implant-Supported Rehabilitation. Appl. Sci., 13.10.3390/app13137358 ↗
23. Accuracy of Multi-Unit Implant Impression: Traditional Techniques versus a Digital Procedure10.1007/s00784-017-2217-9 ↗
24. Accuracy of Single-Unit Ceramic Crown Fabrication after Digital versus Conventional Impressions: A Systematic Review and Meta-Analysis10.4103/jips.jips_534_22 ↗
25. Accuracy of 3-Dimensional Computer-Aided Manufactured Single-Tooth Implant Definitive Casts10.1016/j.prosdent.2018.02.011 ↗
26. Marques, S., Ribeiro, P., Falcão, C., Lemos, B.F., Ríos-Carrasco, B., Ríos-Santos, J.V., and Herrero-Climent, M. (2021). Digital Impressions in Implant Dentistry: A Literature Review. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18031020 ↗
27. Accuracy of Marginal Fit of an Implant-Supported Framework Fabricated by 3D Printing versus Subtractive Manufacturing Technique: A Systematic Review and Meta-Analysis10.1016/j.prosdent.2021.05.010 ↗
28. De Angelis, N., Pesce, P., De Lorenzi, M., and Menini, M. (2023). Evaluation of Prosthetic Marginal Fit and Implant Survival Rates for Conventional and Digital Workflows in Full-Arch Immediate Loading Rehabilitations: A Retrospective Clinical Study. J. Clin. Med., 12.10.3390/jcm12103452 ↗
29. Digital vs Conventional Full-Arch Implant Impressions: A Retrospective Analysis of 36 Edentulous Jaws10.1111/jopr.13536 ↗
30. Accuracy in the Digital Workflow: From Data Acquisition to the Digitally Milled Cast10.1016/j.prosdent.2015.12.004 ↗
31. Intraoral Scanning Reduces Procedure Time and Improves Patient Comfort in Fixed Prosthodontics and Implant Dentistry: A Systematic Review10.1007/s00784-021-04157-3 ↗
32. Park, J.-S., Lim, Y.-J., Kim, B., Kim, M.-J., and Kwon, H.-B. (2020). Clinical Evaluation of Time Efficiency and Fit Accuracy of Lithium Disilicate Single Crowns between Conventional and Digital Impression. Materials, 13.10.3390/ma13235467 ↗
33. Yuzbasioglu, E., Kurt, H., Turunc, R., and Bilir, H. (2014). Comparison of Digital and Conventional Impression Techniques: Evaluation of Patients’ Perception, Treatment Comfort, Effectiveness and Clinical Outcomes. BMC Oral Health, 14.10.1186/1472-6831-14-10 ↗
34. Randomized Controlled Clinical Trial of Digital and Conventional Workflows for the Fabrication of Zirconia-Ceramic Fixed Partial Dentures. Part I: Time Efficiency of Complete-Arch Digital Scans versus Conventional Impressions10.1016/j.prosdent.2018.04.021 ↗
35. Conventional and Digital Impressions for Complete-Arch Implant-Supported Fixed Prostheses: Time, Implant Quantity Effect and Patient Satisfaction10.4047/jap.2022.14.4.212 ↗
36. Patient Preference and Clinical Working Time between Digital Scanning and Conventional Impression Making for Implant-Supported Prostheses: A Systematic Review and Meta-Analysis10.1016/j.prosdent.2020.11.042 ↗
37. A Clinical Study Comparing Digital Scanning and Conventional Impression Making for Implant-Supported Prostheses: A Crossover Clinical Trial10.1016/j.prosdent.2020.12.043 ↗
38. Serrano-Velasco, D., Martín-Vacas, A., Cintora-López, P., Paz-Cortés, M.M., and Aragoneses, J.M. (2024). Comparative Analysis of the Comfort of Children and Adolescents in Digital and Conventional Full-Arch Impression Methods: A Crossover Randomized Trial. Children, 11.10.3390/children11020190 ↗