Fit and Retention of Cobalt–Chromium Removable Partial Denture Frameworks Fabricated with Selective Laser Melting
Source abstract
Abstract
Purpose: To evaluate fit and retention of cobalt–chromium removable partial denture (RPD) frameworks fabricated with selective laser melting (SLM). Methods: Three types of framework for clasp-retained RPDs were virtually designed and fabricated using SLM (n = 30). For comparison, 30 additional frameworks were produced using conventional lost-wax casting. A biomechanical model was created, incorporating extracted teeth mounted on flexible metal posts. Using this model, horizontal constraint forces resulting from a misfit were measured using strain gauges, while vertical forces were not recorded. The constraint force components and resultant forces were determined for all abutment teeth, and the maximum retention force during RPD removal from the model was also assessed. For statistical evaluation, the two fabrication methods were analyzed by calculating the means and standard deviations. Results: The average horizontal constraint forces showed similar values for both fabrication methods (SLM: 3.5 ± 1.0 N, casting: 3.4 ± 1.6 N). The overall scatter of data for cast RPDs was greater compared to those fabricated using SLM, indicating a better reproducibility of the SLM process. With regard to retention, the intended retention force of 5–10 N per abutment tooth was not attained in one of the cast groups, while it was consistently achieved in all SLM groups. Conclusions: This in vitro study found that SLM is a promising option for the manufacture of cobalt–chromium RPD frameworks in terms of fit and retention.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Additive Manufacturing Materials and Processes · Laser Applications in Dentistry and Medicine
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, Heidelberg University Hospital, 69120 Heidelberg, Germany
Department of Removable Prosthodontics, Tokyo Dental College, Tokyo 101-0061, Japan
Department of Prosthetic Dentistry, Medical University Innsbruck, 6020 Innsbruck, Austria
References (32)
Show source-provided references
1. Association between asthma and severe tooth loss in the adult population of the United States10.1080/02770903.2020.1856868 ↗
2. Attachment-retained removable prostheses: Patient satisfaction and quality of life assessment10.1016/j.prosdent.2020.07.006 ↗
3. Biological complications of removable dental prostheses in the moderately reduced dentition: A systematic literature review10.1007/s00784-018-2522-y ↗
4. Prognosis of double crown-retained removable dental prostheses compared with clasp-retained removable dental prostheses: A retrospective study10.1016/j.jpor.2016.12.006 ↗
5. Removable Dental Prosthesis 2.0: Digital from A to Z?10.61872/sdj-2020-03-02 ↗
6. Findrik Balogová, A., Rajtúková, V., Chromy, L., Somos, A., Izariková, G., and Hudák, R. (2022). Biomechanical Testing of Two-Unit Bridges and a Comparison of Replacement Retention Depending on a Cementation Medium, Replacement Position, and Gap Size. J. Funct. Biomater., 13.10.3390/jfb13040286 ↗
7. Accuracy of CAD-CAM-fabricated removable partial dentures10.1016/j.prosdent.2017.04.017 ↗
8. Assessing the Accuracy of Casting and Additive Manufacturing Techniques for Fabrication of a Complete Palatal Coverage Metal Framework10.1111/jopr.13076 ↗
9. Process parameter optimization for removable partial denture frameworks manufactured by selective laser melting10.1016/j.prosdent.2021.04.021 ↗
10. Microstructure, mechanical properties, and retentive forces of cobalt-chromium removable partial denture frameworks fabricated by selective laser melting followed by heat treatment10.1016/j.prosdent.2020.06.038 ↗
11. Retention mechanism of telescopic crowns
12. Conical crowns—A rational telescopic system
13. Retention force and fatigue strength of overdenture attachment systems10.1111/j.1365-2842.2004.01308.x ↗
14. Retentive force of conical crowns combining zirconia and fiber-reinforced composite10.1016/j.jdent.2022.104222 ↗
15. In-vitro fit of experimental full-arch restorations made from monolithic zirconia10.2186/jpr.JPR_D_20_00321 ↗
16. Tactile sensitivity of vital and endodontically treated teeth10.1016/j.jdent.2014.08.016 ↗
17. Noncontact intraoral measurement of force-related tooth mobility10.1007/s00784-009-0344-7 ↗
18. Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering10.1016/j.jpor.2019.07.006 ↗
19. A methodology to study the effects of prosthesis misfit over time: An in vivo model
20. Bone adaptation induced by non-passively fitting implant superstructures: A finite element analysis based on in vivo strain measurements
21. 3D metal printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant-supported prostheses10.1016/j.jmbbm.2020.103821 ↗
22. Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro study10.1016/j.prosdent.2018.10.034 ↗
23. Bone Adaptation Induced by Non–Passively Fitting Implant Superstructures: A Randomized Clinical Trial10.11607/jomi.4331 ↗
24. Preliminary Clinical Application of Removable Partial Denture Frameworks Fabricated Using Computer-Aided Design and Rapid Prototyping Techniques10.11607/ijp.5270 ↗
25. An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks10.1111/jopr.12997 ↗
26. Adaptation of removable partial denture frameworks fabricated by selective laser melting10.1016/j.prosdent.2018.11.010 ↗
27. The Fit Accuracy of Removable Partial Denture Metal Frameworks Using Conventional and 3D Printed Techniques: An In Vitro Study10.5005/jp-journals-10024-2542 ↗
28. Evaluation of removable partial denture frameworks fabricated using 3 different techniques10.1016/j.prosdent.2018.10.013 ↗
29. Retentive force and fitness accuracy of cobalt-chrome alloy clasps for removable partial denture fabricated with SLM technique10.2186/jpr.JPR_D_21_00017 ↗
30. The effect of build orientation on the microstructure and properties of selective laser melting Ti-6Al-4V for removable partial denture clasps10.1016/j.prosdent.2018.12.007 ↗
31. Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: A comparative in vitro study10.1016/j.jpor.2018.08.002 ↗
32. Reduction in anisotropic response of corrosion properties of selective laser melted Co–Cr–Mo alloys by post-heat treatment10.1016/j.dental.2020.10.020 ↗