Nanoscale Polishing Technique of Biomedical Grade NiTi Wire by Advanced MAF Process: Relationship between Surface Roughness and Bacterial Adhesion
Source abstract
Abstract
Nitinol (NiTi), an alloy of nickel and titanium, wires are an important biomedical material that has been used in catheter tubes, guidewires, stents, and other surgical instruments. As such wires are temporarily or permanently inserted inside the human body, their surfaces need to be smoothed and cleaned in order to prevent wear, friction, and adhesion of bacteria. In this study, NiTi wire samples of micro-scale diameters (i.e., Ø 200 μm and Ø 400 μm) were polished by an advanced magnetic abrasive finishing (MAF) process using a nanoscale polishing method. Furthermore, bacterial adhesion (i.e., Escherichia coli (E. coli), and Staphylococcus aureus (S. aureus)) to the initial and final surfaces of NiTi wires were investigated and compared in order to assess the impact of surface roughness on bacterial adhesion to the surfaces of NiTi wires. The finding revealed that the surfaces of NiTi wires were clean and smooth with a lack of particle impurities and toxic components on the final surface polished using the advanced MAF process. The surface roughness Ra values of the Ø 200 μm and Ø 400 μm NiTi wires were smoothly enhanced to 20 nm and 30 nm from the 140 nm and 280 nm initial surface roughness values. Importantly, polishing the surfaces of a biomedical material such as NiTi wire to nano-level roughness can significantly reduce bacterial adhesion on the surface by more than 83.48% in the case of S. aureus, while in the case of E. coli was more than 70.67%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Surface Polishing Techniques · Advanced Machining and Optimization Techniques · Nanofabrication and Lithography Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, 567, Baekje-daero, Jeonju-si 54896, Republic of Korea
Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju 561-656, Republic of Korea
Funding
Korean government · Ministry of Education
References (53)
Show source-provided references
1. Post-processing of NiTi alloys: Issues and challenges10.1007/s11106-018-9933-9 ↗
2. Multi-disciplinary antimicrobial strategies for improving orthopaedic implants to prevent prosthetic joint infections in hip and knee10.1002/jor.23068 ↗
3. Hypersensitivity to orthopedic implants: A review of the literature10.1007/s40744-017-0062-6 ↗
4. Analytical and toxicological aspects of nanomaterials in different product groups: Challenges and opportunities10.1016/j.impact.2022.100416 ↗
5. Graphene enhanced anti-corrosion and biocompatibility of NiTi alloy10.1016/j.impact.2016.10.003 ↗
6. Additive manufacturing of titanium alloys for orthopedic applications: A materials science viewpoint10.1002/adem.201800172 ↗
7. A review on parameters affecting properties of biomaterial SS 316L10.1080/14484846.2020.1752975 ↗
8. A review of squeaking in ceramic total hip prostheses10.1016/j.triboint.2015.09.019 ↗
9. Brief Overview on Nitinol as Biomaterial10.1155/2016/4173138 ↗
10. Sachdeva, R.C.L., Miyazaki, S., and Dughaish, Z. (2001). Encyclopedia of Materials: Science and Technology, Elsevier.
11. Effects of short-time heat treatment and subsequent chemical surface treatment on the mechanical properties, low-cycle fatigue behavior and corrosion resistance of a Ni–Ti (50.9at.% Ni) biomedical alloy wire used for the manufacture of stents10.1016/j.msea.2010.10.043 ↗
12. Restenosis after PCI. Part 1: Pathophysiology and risk factors10.1038/nrcardio.2011.132 ↗
13. Coronary stent as a tubular flow heater in magnetic resonance imaging10.1186/s40543-014-0041-2 ↗
14. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
15. Occupational risk of nano-biomaterials: Assessment of nano-enabled magnetite contrast agent using the BIORIMA Decision Support System10.1016/j.impact.2021.100373 ↗
16. Controlled slow-release drug-eluting stents for the prevention of coronary restenosis: Recent progress and future prospects10.1021/acsami.5b01993 ↗
17. Antibiotic-eluting medical devices for various applications10.1016/j.jconrel.2008.05.020 ↗
18. Coatings as the useful drug delivery system for the prevention of implant-related infections10.1186/s13018-018-0930-y ↗
19. Kline, K.A., and Lewis, A.L. (2017). Urinary Tract Infections: Molecular Pathogenesis and Clinical Management, John Wiley & Sons, Inc.
20. Gram-positive and gram-negative bacterial toxins in sepsis: A brief review10.4161/viru.27024 ↗
21. Bacterial biofilm formation on implantable devices and approaches to its treatment and prevention10.1016/j.heliyon.2018.e01067 ↗
22. Bacterial adhesion to biomaterials: What regulates this attachment? A review10.1016/j.jdsr.2021.05.003 ↗
23. Bacterial adhesion mechanisms on dental implant surfaces and the influencing factors10.1016/j.ijadhadh.2016.03.022 ↗
24. Investigation of bacterial attachment and biofilm formation of two different Pseudoalteromonas species: Comparison of different methods10.1016/j.ijadhadh.2015.11.004 ↗
25. Bacterial-nanostructure interactions: The role of cell elasticity and adhesion forces10.1016/j.jcis.2019.03.050 ↗
26. Emergent heterogeneous microenvironments in biofilms: Substratum surface heterogeneity and bacterial adhesion force-sensing10.1093/femsre/fuy001 ↗
27. Bacterial adhesion on soft materials: Passive physicochemical interactions or active bacterial mechanosensing?10.1002/adhm.201801323 ↗
28. Adhesion forces between E-coli bacteria and biomaterial surfaces10.1021/la981104e ↗
29. Effects of surface roughness and texture on the bacterial adhesion on the bearing surface of bio-ceramic joint implants: An in vitro study10.1016/j.ceramint.2019.11.139 ↗
30. Implant-associated infections: A review of the safety of cardiac implants
31. Reduction of bacterial adhesion on ion-implanted stainless steel surfaces10.1016/j.medengphy.2007.04.004 ↗
32. Wear and corrosion resistance of anti-bacterial Ti-Cu-N coatings on titanium implants10.1016/j.apsusc.2014.08.163 ↗
33. Thakur, A., Kumar, A., Kaya, S., Marzouki, R., Zhang, F., and Guo, L. (2022). Recent advancements in surface modification, characterization and functionalization for enhancing the biocompatibility and corrosion resistance of biomedical implants. Coatings, 12.10.3390/coatings12101459 ↗
34. Surface finishing of cobalt chromium alloy femoral knee components10.1016/j.cirp.2014.03.020 ↗
35. Using inverse replica fixture technique for improving nano-finishing of hip joint implant in abrasive flow finishing process10.1007/s00170-020-06064-5 ↗
36. Nanofinishing of freeform surfaces (knee joint implant) by rotational-magnetorheological abrasive flow finishing (R-MRAFF) process10.1016/j.precisioneng.2015.04.014 ↗
37. Corrosion and wear-corrosion behavior of NiTi modified by plasma source ion implantation10.1016/S0142-9612(03)00271-0 ↗
38. Surface modification of NiTi by plasma based ion implantation for application in harsh environments10.1016/j.apsusc.2012.09.161 ↗
39. Effect of ion-implantation on surface characteristics of nickel titanium and titanium molybdenum alloy arch wires
40. Engineering. Effect of laser polishing on the surface roughness and corrosion resistance of nitinol stents
41. Effect of electrolytic ZrO2 coatings on the breakdown potential of NiTi wires used as endovascular implants
42. Electrochemical deposition and characterization of ZrO2 ceramic nanocoatings on superelastic NiTi alloy10.1016/j.apsusc.2018.04.154 ↗
43. Laser polishing of additively manufactured Ti-6Al-4V: Microstructure evolution and material properties10.2351/7.0000065 ↗
44. ToF-SIMS Characterization of Nanostructured ZrO2 Coatings Applied to Near Equiatomic Ni-Ti Alloy10.1590/1980-5373-mr-2019-0189 ↗
45. Ion Implantation Doping in Silicon Carbide and Gallium Nitride Electronic Devices10.3390/micro2010002 ↗
46. Ion sources for use in ion implantation10.1016/0168-583X(89)90139-0 ↗
47. Current, M., Jose, S., and Ca, N. (2007, January 8–12). Safety Issues in Ion Implantation for Fabrication of Semiconductor Materials and Devices. Proceedings of the Health Physics Society, Portland, OR, USA.
48. Integrating autotransplantation into the orthodontic treatment of an adolescent patient with mutilated dentition10.1016/j.xaor.2021.07.002 ↗
49. Biomedical applications of shape memory alloys10.1155/2011/501483 ↗
50. Biomechanical Properties of Nitinol Staples: Effects of Troughing, Effective Leg Length, and 2-Staple Constructs10.1016/j.jhsa.2018.08.017 ↗
51. Baron, T.H., Kozarek, R.A., and Carr-Locke, D.L. (2019). ERCP, Elsevier. [3rd ed.].
52. Stoeckel, D., Pelton, A., and Duerig, T. (2009). Shape Memory Alloys for Biomedical Applications, Woodhead Publishing.
53. Nanomaterial-Based Antimicrobial Coating for Biomedical Implants: New Age Solution for Biofilm-Associated Infections10.1021/acsomega.2c06211 ↗