journal article·2022-02-04Open access

Low-Modulus PMMA Has the Potential to Reduce Stresses on Endplates after Cement Discoplasty

Susanne Lewin, Peter Försth, Cecilia Persson

Abstract

Cement discoplasty has been developed to treat patients with advanced intervertebral disc degeneration. In discoplasty, poly(methylmethacrylate) (PMMA) bone cement is injected into the disc, leading to reduced pain and certain spinal alignment correction. Standard PMMA-cements have much higher elastic modulus than the surrounding vertebral bone, which may lead to a propensity for adjacent fractures. A PMMA-cement with lower modulus might be biomechanically beneficial. In this study, PMMA-cements with lower modulus were obtained using previously established methods. A commercial PMMA-cement (V-steady®, G21 srl) was used as control, and as base cement. The low-modulus PMMA-cements were modified by 12 vol% (LA12), 16 vol% (LA16) and 20 vol% (LA20) linoleic acid (LA). After storage in 37 °C PBS from 24 h up to 8 weeks, specimens were tested in compression to obtain the material properties. A lower E-modulus was obtained with increasing amount of LA. However, with storage time, the E-modulus increased. Standard and low-modulus PMMA discoplasty were compared in a previously developed and validated computational lumbar spine model. All discoplasty models showed the same trend, namely a substantial reduction in range of motion (ROM), compared to the healthy model. The V-steady model had the largest ROM-reduction (77%), and the LA20 model had the smallest (45%). The average stress at the endplate was higher for all discoplasty models than for the healthy model, but the stresses were reduced for cements with higher amounts of LA. The study indicates that low-modulus PMMA is promising for discoplasty from a mechanical viewpoint. However, validation experiments are needed, and the clinical setting needs to be further considered.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spine and Intervertebral Disc Pathology · Spinal Fractures and Fixation Techniques · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Science and Engineering, Division of Biomedical Engineering, Uppsala University, 751 21 Uppsala, Sweden

Department of Surgical Sciences, Division of Orthopedics, Uppsala University, 751 85 Uppsala, Sweden

Funding

EIT Health

References (47)

Show source-provided references
1. Prevalence and distribution of intervertebral disc degeneration over the entire spine in a population-based cohort: The Wakayama Spine Study10.1016/j.joca.2013.10.019 ↗
2. Lumbar disc degeneration: Epidemiology and genetics
3. Trends, Major Medical Complications, and Charges Associated With Surgery for Lumbar Spinal Stenosis in Older Adults10.1001/jama.2010.338 ↗
4. Experiences with PMMA cement as a stand-alone intervertebral spacer10.1007/s00132-014-3060-1 ↗
5. Targeted therapy for low back pain in elderly degenerative lumbar scoliosis: A cohort study10.1097/BRS.0000000000001524 ↗
6. Percutaneous cement discoplasty for the treatment of advanced degenerative disk disease in elderly patients10.1007/s00586-018-5547-7 ↗
7. Percutaneous Cement Discoplasty for the Treatment of Advanced Degenerative Disc Conditions: A Case Series Analysis10.1177/2192568219873885 ↗
8. Indirect foraminal decompression and improvement in the lumbar alignment after percutaneous cement discoplasty10.1007/s00586-019-05966-7 ↗
9. Long-term outcome of targeted therapy for low back pain in elderly degenerative lumbar scoliosis10.1007/s00586-021-06805-4 ↗
10. Bone Marrow Edema and Low Back Pain in Elderly Degenerative Lumbar Scoliosis: A Cross-Sectional Study10.1097/BRS.0000000000001315 ↗
11. Prevalence of Vertebral Endplate Modic Changes in Degenerative Lumbar Scoliosis and Its Associated Factors Analysis10.1097/BRS.0b013e31825bfb85 ↗
12. An exploratory study of loading and morphometric factors associated with specific failure modes in fatigue testing of lumbar motion segments10.1016/j.clinbiomech.2005.10.001 ↗
13. A comprehensive classification of thoracic and lumbar injuries10.1007/BF02221591 ↗
14. The influence of cage positioning and cage type on cage migration and fusion rates in patients with monosegmental posterior lumbar interbody fusion and posterior fixation10.1007/s00586-009-1036-3 ↗
15. Testing the impact of discoplasty on the biomechanics of the intervertebral disc with simulated degeneration: An in vitro study10.1016/j.medengphy.2020.07.024 ↗
16. Trabecular bone modulus–density relationships depend on anatomic site10.1016/S0021-9290(03)00071-X ↗
17. Bone Volume Fraction Explains the Variation in Strength and Stiffness of Cancellous Bone Affected by Metastatic Cancer and Osteoporosis10.1007/s00223-008-9174-x ↗
18. Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography10.1016/S8756-3282(03)00210-2 ↗
19. Mathematical relationships between bone density and mechanical properties: A literature review10.1016/j.clinbiomech.2007.08.024 ↗
20. Persson, C., and Lopez, A.U.S. (2021, December 18). Cl, (71), Acrylic Cements for Bone Augmentation. Applicant: INOSSIA AB, Stockholm (SE), (2000) 42. Available online: https://worldwide.espacenet.com/patent/search/family/051689845/publication/WO2014168565A1?q=pn%3DPL2983725T3.
21. Compressive mechanical properties and cytocompatibility of bone-compliant, linoleic acid-modified bone cement in a bovine model10.1016/j.jmbbm.2014.01.002 ↗
22. In vivo response to a low-modulus PMMA bone cement in an ovine model10.1016/j.actbio.2018.03.014 ↗
23. Robo, C., Wenner, D., Ubhayasekera, S.J.K.A., Hilborn, J., Öhman-Mägi, C., and Persson, C. (2021). Functional Properties of Low-Modulus PMMA Bone Cements Containing Linoleic Acid. J. Funct. Biomater., 12.10.3390/jfb12010005 ↗
24. Long-term mechanical properties of a novel low-modulus bone cement for the treatment of osteoporotic vertebral compression fractures10.1016/j.jmbbm.2021.104437 ↗
25. The importance of the endplate for interbody cages in the lumbar spine10.1007/s00586-003-0556-5 ↗
26. The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: Experimental and finite-element analysis10.1007/s00586-005-0915-5 ↗
27. Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: Finite element analysis10.1007/s00586-002-0505-8 ↗
28. Biomechanical effects of laminectomies in the human lumbar spine: A finite element study10.1016/j.spinee.2020.07.016 ↗
29. Biomechanical Rationale for Using Polyetheretherketone (PEEK) Spacers for Lumbar Interbody Fusion–A Finite Element Study10.1097/01.brs.0000250177.84168.ba ↗
30. (2021, July 06). Standard—Implants for Surgery—Acrylic Resin Cements ISO 5833, Sven. Institutet För Stand. SIS. (n.d.). Available online: https://www.sis.se/produkter/halso-och-sjukvard/medicinsk-utrustning/kirurgiska-implantat-proteser-och-ortoser/iso5833/.
31. R Core Team (2014). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing. Available online: http://www.R-project.org/.
32. Robust statistical methods in R using the WRS2 package10.3758/s13428-019-01246-w ↗
33. FEBio finite element models of the human lumbar spine10.1080/10255842.2018.1478967 ↗
34. Parametric convergence sensitivity and validation of a finite element model of the human lumbar spine10.1080/10255842.2010.493517 ↗
35. Finite Element Lumbar Spine Facet Contact Parameter Predictions are Affected by the Cartilage Thickness Distribution and Initial Joint Gap Size10.1115/1.4004287 ↗
36. Effect of multilevel lumbar disc arthroplasty on spine kinematics and facet joint loads in flexion and extension: A finite element analysis10.1007/s00586-010-1382-1 ↗
37. Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method10.1016/j.jbiomech.2005.07.026 ↗
38. Validation and application of an intervertebral disc finite element model utilizing independently constructed tissue-level constitutive formulations that are nonlinear, anisotropic, and time-dependent10.1016/j.jbiomech.2014.06.008 ↗
39. Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants10.1007/s005860050045 ↗
40. New In Vivo Measurements of Pressures in the Intervertebral Disc in Daily Life10.1097/00007632-199904150-00005 ↗
41. FEBio: Finite Elements for Biomechanics10.1115/1.4005694 ↗
42. (2021, December 18). G21 (G21 S.r.l., San Possidonio, Italy). G21—Bone Cements for Vertebral Consolidation (Product Information) 2021. Available online: http://madison-medical.gr/images/PDF%20cements/G-21_Bone%20cements%20for%20vertebral%20consolidation%20-%20ENG.pdf.
43. Mechanical and morphological characterization of PMMA/bone composites in human femoral heads10.1016/j.jmbbm.2020.104247 ↗
44. Experimental and computational models to investigate the effect of adhesion on the mechanical properties of bone-cement composites10.1002/jbm.b.31886 ↗
45. The mechanical behavior of PMMA/bone specimens extracted from augmented vertebrae: A numerical study of interface properties, PMMA shrinkage and trabecular bone damage10.1016/j.jbiomech.2012.02.012 ↗
46. A novel three-dimensional volumetric method to measure indirect decompression after percutaneous cement discoplasty
47. A study on the structural properties of the lumbar endplate: Histological structure, the effect of bone density, and spinal level10.1097/BRS.0b013e3181a2ea0a ↗