journal article·2022-01-02Open access

Physical Characterization and In Vitro Toxicity Test of PDMS Synthesized from Low-Grade D4 Monomer as a Vitreous Substitute in the Human Eyes

Diba Grace Auliya, Soni Setiadji, Fitrilawati Fitrilawati, Risdiana Risdiana

Abstract

Polydimethylsiloxane (PDMS) is one of the most superior materials and has been used as a substitute for vitreous humor in the human eye. In previous research, we have succeeded in producing PDMS with low and medium viscosity using octamethylcyclotetrasiloxane (D4) monomer with a low grade of 96%. Both have good physical properties and are comparable to commercial product PDMS and PDMS synthesized using D4 monomer with a high grade of 98%. An improvement of the synthesis process is needed to ensure that PDMS synthesized from a low-grade D4 monomer under specific synthesis conditions can repeatedly produce high-quality PDMS. Apart from good physical properties, the PDMS as a substitute for vitreous humor must also be safe and not cause other disturbances to the eyes. Here, we reported the process of synthesizing and characterizing the physical properties of low- and medium-viscosity PDMS using a low-grade D4 monomer. We also reported for the first time the in vitro toxicity test using the Hen’s Egg Test Chorioallantoic Membrane (HET-CAM) test method. We have succeeded in obtaining PDMS with viscosities of 1.15 Pa.s, 1.17 Pa.s, and 1.81 Pa.s. All samples have good physical properties such as refractive index, surface tension, and functional groups that are similar to commercial PDMS. The HET-CAM test results showed that all samples did not show signs of irritation indicating that samples were non-toxic. From the results of this study, it can be concluded that PDMS synthesized from a low-grade D4 monomer under specific synthesis conditions by the ROP method is very safe and has the potential to be developed as a substitute for vitreous humor in human eyes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Retinal and Macular Surgery · Intraocular Surgery and Lenses · Glaucoma and retinal disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang km 21 Jatinangor, Sumedang 45363, Indonesia

Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang km 21 Jatinangor, Sumedang 45363, Indonesia

Department of Chemistry, Faculty of Sciences and Technology, UIN Sunan Gunung Djati Bandung, Jl. A.H. Nasution No. 105, Cibiru, Bandung 40614, Indonesia

Funding

Padjadjaran University · Ministry of Research, Technology and Higher Education

References (17)

Show source-provided references
1. In Vivo Emulsification Analysis of 1000 cs and 5000 cs Silicone Oil after Rhegmatogenous Retinal Detachment Vitrectomy Surgery10.4236/ojoph.2017.74031 ↗
2. Silicone Oils as Vitreous Substitutes10.1016/S0079-6700(97)00046-4 ↗
3. Characterization of Optical and Structure Properties of Polydimethylsiloxanes10.4028/www.scientific.net/MSF.827.99 ↗
4. In Vitro Emulsification Assessment of New Silicone Oils10.1136/bjo.2009.170852 ↗
5. Safety of Silicone Oils as Introcular Medical Device: An In Vitro Cytotoxicity Study10.1016/j.exer.2020.108018 ↗
6. Ocular Toxicity of Low-Molecular-Weight Components of Silicone and Fluorosilicone Oils
7. Chemical Impurities and Contaminants in Different Silicone Oils in Human Eyes before and After Prolonged Use10.1007/s00417-010-1464-0 ↗
8. Toxicity study of agrochemicals on chorioallantoic membrane of the egg
9. ECITTS: An integrated approach to the application of in vitro test systems to the hazard assessment of chemicals10.1177/026119299202000307 ↗
10. The Chick Embryo in Toxicology: An Alternative to the Rabit Eye10.1016/0278-6915(85)90031-6 ↗
11. The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials10.1002/jbm.10152 ↗
12. Synthesis of Low Viscosity Polydimethylsiloxane Using Low Grade of Octamethylcyclotetrasiloxane10.4028/www.scientific.net/MSF.1028.365 ↗
13. Synthesis and Characterization of Polydimethylsiloxane (PDMS) with Medium Viscosity via Ring-Opening Polymerization10.4028/www.scientific.net/MSF.1028.346 ↗
14. ICCVAM (2021, April 28). Recommended Test Method Protocol: Hen’s Egg Test–Chorioallantoic Membrane (HET-CAM) Test Method, Available online: http://iccvam.niehs.nih.gov/methods/ocutox/MildMod-TMER.htm.
15. Recent advances in polymeric vitreous substitutes10.1586/17469899.2.2.255 ↗
16. Interlaboratory validation of in vitro eye irritation tests for cosmetic ingredients. (2) Chorioallantoic membrane (CAM) test10.1016/S0887-2333(98)00065-4 ↗
17. In Vitro Retinal Tolerance of Various Heavy Silicone Oils10.1167/iovs.06-0941 ↗