Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis
Source abstract
Abstract
(1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25–50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant’s superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany
Department of Reconstructive Dentistry and Gerodontology, Bern University, 3012 Bern, Switzerland
References (80)
Show source-provided references
1. Long-term follow-up of osseointegrated titanium implants using clinical, radiographic and microbiological parameters10.1034/j.1600-0501.2002.130202.x ↗
2. Osseointegration—Molecular eventsat the bone–implant interface: A review10.1016/j.ajoms.2012.01.008 ↗
3. Consensus statements and clinical recommendations for implant loading protocols10.11607/jomi.2013.g4 ↗
4. Understanding and controlling the bone–implant interface10.1016/S0142-9612(99)00160-X ↗
5. Stability of Tapered and Parallel-Walled Dental Implants: A Systematic Review and Meta-Analysis10.1111/cid.12623 ↗
6. Herrero-Climent, M., Lemos, B.F., Herrero-Climent, F., Falcao, C., Oliveira, H., Herrera, M., Gil, F.J., Ros-Carrasco, B., and Ros-Satos, J.V. (2020). Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study. Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17124436 ↗
7. The Split Crest Technique and Dental Implants: A Systematic Review and Meta-Analysis10.1016/j.ijom.2016.08.017 ↗
8. Effects on Primary Stability of Three Different Techniques for Implant Site Preparation in Synthetic Bone Models of Different Densities10.1016/j.bjoms.2016.07.004 ↗
9. Immediate Versus Delayed Loading of Dental Implants Supporting Fixed Full-Arch Maxillary Prostheses: A 10-year Follow-up Report
10. Caramês, J.M.M., Marques, D.N.D.S., Caramês, G.B., Francisco, H.C.O., and Vieira, F.A. (2021). Implant survival in immediately loaded full-arch rehabilitations following an anatomical classification system—A retrospective study in 1200 edentulous jaws. J. Clin. Med., 10.10.3390/jcm10215167 ↗
11. Implant-supported immediately loaded complete arch rehabilitations with a mean follow-up of 10 years: A prospective clinical study10.1111/jopr.13116 ↗
12. Immediate function dental implants inserted with less than 30 Ncm of torque in full-arch maxillary rehabilitations using the All-on-4 concept: Retrospective study10.1016/j.ijom.2018.04.008 ↗
13. Sensitivity and specificity of stability criteria for immediately loaded splinted maxillary implants10.1111/cid.12283 ↗
14. Clinical efficacy of immediate implant loading protocols compared to conventional loading depending on the type of the restoration: A systematic review10.1111/clr.12428 ↗
15. Compensating for Poor Primary Implant Stability in Different Bone Densities by Varying Implant Geometry: A Laboratory Study10.1016/j.ijom.2015.08.985 ↗
16. Comparison between Tapered and Cylindrical Implants in the Posterior Regions of the Mandible: A Prospective, Randomized, Split-Mouth Clinical Trial Focusing on Implant Stability Changes during Early Healing10.1111/cid.12501 ↗
17. Primary Apical Stability of Tapered Implants Through Reduction of Final Drilling Dimensions in Different Bone Density Models: A Biomechanical Study10.1097/ID.0000000000000479 ↗
18. Staedt, H., Heimes, D., Lehmann, K.M., Ottl, P., Bjelopavlovic, M., Wagner, W., Al-Nawas, B., and Kämmerer, P.W. (2021). Does the Modification of the Apical Geometry of a Dental Implant Affect Its Primary Stability? A Comparative Ex Vivo Study. Materials, 7.10.3390/ma14071728 ↗
19. Prospective clinical evaluation of 835 multi-threaded tapered screw-vent implants: Results after two years of functional loading10.1563/1548-1336(2007)33[225:PCEOMT]2.0.CO;2 ↗
20. Critical review of immediate implant loading10.1034/j.1600-0501.2003.00950.x ↗
21. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
22. Surgical determinants of clinical success of osseointegrated oral implants: A review of the litera-ture
23. Validity and clinical significance of biomechanical testing of implant/bone interface10.1111/j.1600-0501.2006.01365.x ↗
24. How does dental implant macrogeometry affect primary implant stability? A narrative review10.1186/s40729-023-00485-z ↗
25. Measurement of dental implant stability by resonance frequency analysis: A review of the literature
26. Application and Interpretation of Resonance Frequency Analysis in Auditory Osseointegrated Implants: A Review of Literature and Establishment of Practical Recommendations10.1097/MAO.0000000000000833 ↗
27. Clinical evaluation of osseointegration using resonance frequency analysis
28. The clinical significance of implant stability quotient (ISQ) measurements: A literature review
29. Implant loading protocols for edentulous patients with fixed prostheses: A systematic review and meta-analysis10.11607/jomi.2014suppl.g4.3 ↗
30. Implant Insertion Torque: Its Role in Achieving Primary Stability of Restorable Dental Implants
31. The influence of insertion torque values on the failure and complication rates of dental implants: A systematic review and meta-analysis10.1111/cid.12993 ↗
32. A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability
33. Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion10.1111/j.1708-8208.2005.tb00076.x ↗
34. Loading protocols for implant-supported overdentures in the edentulous jaw: A systematic review and meta-analysis10.11607/jomi.2014suppl.g4.4 ↗
35. The impact of immediately placed and restored single tooth implants on hard and soft tissues in the anterior maxilla
36. Clinical effect of the high insertion torque on dental implants: A systematic review and meta-analysis10.1016/j.prosdent.2020.06.012 ↗
37. Different loading strategies of dental implants: A Cochrane systematic review of randomised controlled clinical trials
38. Healing of implants installed in over- or un-der-prepared sites: An experimental study in dogs10.1111/clr.12390 ↗
39. Loading protocols for single-implant crowns: A systematic review and meta-analysis10.11607/jomi.2014suppl.g4.1 ↗
40. Nonremoval of immediate abutments in cases involving subcrestally placed postextractive tapered single implants: A randomized controlled clinical study10.1111/cid.12051 ↗
41. The Effect of Insertion Torque on the Clinical Outcome of Single Implants: A Randomized Clinical Trial10.1111/cid.12337 ↗
42. Longitudinal analysis on the effect of insertion torque on delayed single implants: A 3-year randomized clinical study10.1111/cid.12586 ↗
43. Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
44. Preoperative evaluation of bone quality and bone density using novel CT/microCT-based hard-normal-soft classification system
45. The excessive loss of Branemark fixtures in type IV bone: A 5-year analysis10.1902/jop.1991.62.1.2 ↗
46. Histomorphometric and fluorescence microscopic analysis of bone remodelling after installa-tion of implants using an osteotome technique10.1034/j.1600-0501.2002.130604.x ↗
47. Influence of lateral pressure to the implant bed on osseointegration: An experimental study in dogs10.1111/j.1600-0501.2010.01941.x ↗
48. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
49. Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study10.1016/j.jobcr.2020.08.020 ↗
50. The effect of the thread depth on the mechanical properties of the dental implant10.4047/jap.2015.7.2.115 ↗
51. Makary, C., Menhall, A., Zammarie, C., Lombardi, T., Lee, S.Y., Stacchi, C., and Park, K.B. (2019). Primary Stability Optimization by Using Fixtures with Different Thread Depth According to Bone Density: A Clinical Prospective Study on Early Loaded Implants. Materials, 12.10.3390/ma12152398 ↗
52. Effect of implant macro-design on primary stability: A prospective clinical study
53. Comuzzi, L., Tumedei, M., Di Pietro, N., Romasco, T., Heydari Sheikh Hossein, H., Montesani, L., Inchingolo, F., Piattelli, A., and Covani, U. (2023). A Comparison of Conical and Cylindrical Implants Inserted in an In Vitro Post-Extraction Model Using Low-Density Polyurethane Foam Blocks. Materials, 14.10.20944/preprints202306.0732.v1 ↗
54. Analysis of the influence of implant shape on primary stability using the correlation of multiple methods10.1007/s00784-015-1417-4 ↗
55. Peroperative estimation of bone quality and primary dental implant stability10.1016/j.jmbbm.2018.12.035 ↗
56. Sartoretto, S.C., Shibli, J.A., Javid, K., Cotrim, K., Canabarro, A., Louro, R.S., Lowenstein, A., Mourão, C.F., and Moraschini, V. (2023). Comparing the Long-Term Success Rates of Tooth Preservation and Dental Implants: A Critical Review. J. Funct. Biomater., 3.10.3390/jfb14030142 ↗
57. Patient experience of, and satisfaction with, delayed-immediate vs. delayed single-tooth implant placement10.1111/j.1600-0501.2004.01033.x ↗
58. Immediate occlusal loading the same day or the after implant placement: Comparison of 2 different time frames in total edentulous lower jaws10.1563/0678.1 ↗
59. Immediate versus early loading of two implants placed with a flapless technique sup-porting mandibular bar-retained overdentures: A single-blinded, randomised controlled clinical trial
60. Influence of implant positioning in extraction sockets on osseointegration: Histomorphometric analyses in dogs10.1111/j.1600-0501.2009.01842.x ↗
61. Modeling of the buccal and lingual bone walls of fresh extraction sites following implant installation
62. Early healing of implants placed into fresh extraction sockets: An experimental study in the beagle dog. De novo bone formation10.1111/j.1600-051X.2008.01363.x ↗
63. Bio-Oss collagen in the buccal gap at immediate implants: A 6-month study in the dog
64. Deproteinized bovine bone mineral in marginal defects at implants installed immediately into extraction sockets: An experimental study in dogs10.1111/j.1600-0501.2011.02202.x ↗
65. Immediate implant placement with or without socket grafting: A systematic review and meta-analysis10.1111/cid.13079 ↗
66. Immediate implant placement with or without immediate provisionalization: A systematic review and meta-analysis10.1111/jcpe.13686 ↗
67. A systematic review of post-extractional alveolar hard and soft tissue dimensional changes in humans10.1111/j.1600-0501.2011.02375.x ↗
68. Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation
69. Delgado-Ruiz, R., Gold, J., Somohano Marquez, T., and Romanos, G. (2020). Under-Drilling versus Hybrid Osseodensification Technique: Differences in Implant Primary Stability and Bone Density of the Implant Bed Walls. Materials, 2.10.3390/ma13020390 ↗
70. Influence of different drilling protocols and bone density on the insertion torque of dental implants
71. (1997). Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments. Standard No. ASTM F1839.
72. The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks10.1016/j.prosdent.2017.04.012 ↗
73. Comparison of Osteotome and Conventional Drilling Techniques for Primary Implant Stability: An In Vitro Study10.1563/aaid-joi-D-15-00176 ↗
74. Comuzzi, L., Iezzi, G., Piattelli, A., and Tumedei, M. (2019). An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of Nano Short Dental Implants. Polymers, 11.10.3390/polym11061020 ↗
75. Density of bone: Effect on treatment plans, surgical approach, healing, and progressive boen loading
76. Comuzzi, L., Tumedei, M., Romasco, T., Petrini, M., Afrashtehfar, K.I., Inchingolo, F., Piattelli, A., and Di Pietro, N. (2022). Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets. J. Funct. Biomater., 1.10.3390/jfb14010010 ↗
77. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone10.1111/j.1365-2842.2010.02117.x ↗
78. Analysis of CBCT Bone Density Using the Hounsfield Scale10.3390/prosthesis4030033 ↗
79. CBCT-based bone quality assessment: Are Hounsfield units applicable?10.1259/dmfr.20140238 ↗
80. Why guided when freehand is easier, quicker, and less costly?10.1563/aaid-joi-D-14-00231 ↗