Bio-Corrosion of Magnesium Alloys for Orthopaedic Applications
Source abstract
Abstract
Three Mg alloys, Mg–1.34% Ca–3% Zn (MCZ), Mg–1.34% Ca–3% Zn–0.2% Sr (MCZS), and Mg–2% Sr (MS), were examined to understand their bio-corrosion behavior. Electrochemical impedance spectroscopy and polarization scans were performed after 6 days of immersion in cell culture medium, and ion release and changes in media pH were tracked over a 28 day time period. Scanning electron microscopy (SEM) of alloy microstructure was performed to help interpret the results of the electrochemical testing. Results indicate that corrosion resistance of the alloys is as follows: MCZ > MCZS > MS.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomedical Engineering, University at Buffalo, Buffalo, NY 14214, USA
Department of Orthopaedics, University at Buffalo, Buffalo, NY 14214, USA
References (47)
Show source-provided references
1. Silk, metal and bone: Why take implants out?10.1038/nrrheum.2014.57 ↗
2. Understanding magnesium corrosion: A framework for improved alloy performance10.1002/adem.200310405 ↗
3. Corrosion mechanisms of magnesium alloys10.1002/(SICI)1527-2648(199909)1:1<11::AID-ADEM11>3.0.CO;2-N ↗
4. Magnesium and its alloys as orthopedic biomaterials: A review10.1016/j.biomaterials.2005.10.003 ↗
5. Bilezikian, J., Raisz, L., and Martin, T. (2008). Magnesium homeostasis. Principles of Bone Biology, Academic Press.
6. The effect of surface chemistry modification of titanium alloy on signalling pathways in human osteoblasts10.1016/j.biomaterials.2005.05.024 ↗
7. Osteoblastic cell response on fluoridated hydroxyapatite coatings: The effect of magnesium incorporation10.1088/1748-6041/5/5/054114 ↗
8. Mechanisms of magnesium-stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants10.1002/jbm.10270 ↗
9. Effect of titanium surface calcium and magnesium on adhesive activity of epithelial-like cells and fibroblasts10.1007/s13758-012-0027-9 ↗
10. Biodegradable magnesium scaffolds: Part II: Peri-implant bone remodeling10.1002/jbm.a.31293 ↗
11. Bone-implant interface strength and osseointegration: Biodegradable magnesium alloy versus standard titanium control10.1016/j.actbio.2010.08.020 ↗
12. In vivo corrosion of four magnesium alloys and the associated bone response10.1016/j.biomaterials.2004.09.049 ↗
13. Antibacterial properties of magnesium in vitro and in an in vivo model of implant-associated methicillin-resistant staphylococcus aureus infection10.1128/AAC.03936-14 ↗
14. Enhanced antibacterial properties, biocompatibility, and corrosion resistance of degradable Mg-Nd-Zn-Zr alloy10.1016/j.biomaterials.2015.02.096 ↗
15. Antibacterial biodegradable Mg-Ag alloys10.22203/eCM.v025a20 ↗
16. Brooks, E.K., Ahn, R., Tobias, M.E., Hansen, L.A., Luke-Marshall, N.R., Wild, L., Campagnari, A.A., and Ehrensberger, M.T. (2017). Magnesium alloy AZ91 exhibits antimicrobial properties in vitro but not in vivo. J. Biomed. Mater. Res. B Appl. Biomater.10.1002/jbm.b.33839 ↗
17. Review of recent developments in the field of magnesium corrosion10.1002/adem.201400434 ↗
18. Magnesium biomaterials for orthopedic application: A review from a biological perspective10.1002/jbm.b.33113 ↗
19. Review of corrosion-resistant conversion coatings for magnesium and its alloys10.5006/1.3563639 ↗
20. The in vivo and in vitro corrosion of high-purity magnesium and magnesium alloys WZ21 and AZ9110.1016/j.corsci.2013.06.019 ↗
21. A survey of bio-corrosion rates of magnesium alloys10.1016/j.corsci.2009.09.033 ↗
22. Magnesium biomaterials: Past, present and future10.1179/1743278212Y.0000000034 ↗
23. Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines10.1016/j.actbio.2009.09.024 ↗
24. Zinc may increase bone formation through stimulating cell proliferation, alkaline phosphatase activity and collagen synthesis in osteoblastic MC3T3-E1 cells10.4162/nrp.2010.4.5.356 ↗
25. The effect of calcium ion concentration on osteoblast viability, proliferation and differentiation in monolayer and 3D culture10.1016/j.biomaterials.2005.01.006 ↗
26. Strontium content and collagen-I coating of magnesium-zirconia-strontium implants influence osteogenesis and bone resorption
27. Strontium enhances osteogenic differentiation of mesenchymal stem cells and in vivo bone formation by activating Wnt/catenin signaling10.1002/stem.646 ↗
28. Investigation of the mechanical and degradation properties of Mg-Sr and Mg-Zn-Sr alloys for use as potential biodegradable implant materials10.1016/j.jmbbm.2011.07.018 ↗
29. Performance-driven design of biocompatible mg alloys10.1007/s11837-011-0089-z ↗
30. In vitrocorrosion survey of Mg-x Ca and Mg-3Zn-y Ca alloys with and without calcium phosphate conversion coatings10.1179/1743278212Y.0000000019 ↗
31. In vitro and in vivo studies on a Mg-Sr binary alloy system developed as a new kind of biodegradable metal10.1016/j.actbio.2012.02.018 ↗
32. Biocompatibility and biodegradability of Mg-Sr alloys: The formation of sr-substituted hydroxyapatite10.1016/j.actbio.2012.07.045 ↗
33. Accurate electrochemical measurement of magnesium corrosion rates; a combined impedance, mass-loss and hydrogen collection study10.1016/j.electacta.2013.12.124 ↗
34. Corrosion and mechanical performance of AZ91 exposed to simulated inflammatory conditions10.1016/j.msec.2015.11.059 ↗
35. Orazem, M., and Tribollet, B. (2008). Electrochemical Impedance Spectroscopy, John Wiley & Sons, Inc.10.1002/9780470381588 ↗
36. Utilization of the specific pseudocapacitance for determination of the area of corroding steel surfaces10.5006/1.3583972 ↗
37. Polarization resistance method for determination of instantaneous corrosion rates10.5006/1.3280536 ↗
38. The effect of selected alloying element additions on properties of Mg-based alloy as bioimplants: A literature review10.1007/s11706-013-0210-z ↗
39. Effect of ph on the grain size dependence of magnesium corrosion10.5006/i0010-9312-68-6-507 ↗
40. Corrosion of magnesium alloys: The role of alloying10.1179/1743280414Y.0000000046 ↗
41. Effect of heat treatment on corrosion and electrochemical behaviour of AZ91D magnesium alloy10.1023/A:1022698916817 ↗
42. Magnesium implant alloy with low levels of strontium and calcium: The third element effect and phase selection improve bio-corrosion resistance and mechanical performance10.1016/j.msec.2013.11.011 ↗
43. Effects of Mg17Sr2 phase on the bio-corrosion behavior of Mg-Zr-Sr alloys10.1002/adem.201500222 ↗
44. In vitro dissolution of magnesium-calcium binary alloys: Clarifying the unique role of calcium additions in bioresorbable magnesium implant alloys10.1002/jbm.b.31687 ↗
45. The effect of scanning electrochemical potential on the short-term impedance of commercially pure titanium in simulated biological conditions10.1002/jbm.a.32736 ↗
46. Titanium is not “the most biocompatible metal” under cathodic potential: The relationship between voltage and MC3T3 preosteoblast behavior on electrically polarized cpti surfaces10.1002/jbm.a.32622 ↗
47. Influence of MC3T3-E1 preosteoblast culture on the corrosion of a T6-treated AZ91 alloy10.1002/jbm.b.33378 ↗