journal article·2024-12-12Open access

Effectiveness of CAD-CAM Milled Versus DMLS Titanium Frameworks for Hybrid Denture Prosthesis: A Narrative Review

Yahya Deeban

Journal of Functional Biomaterials· Volume 15· Issue 12

Abstract

This narrative review aimed to evaluate the effectiveness of computer-aided design (CAD), computer-aided manufacturing (CAM) milled, and direct metal laser sintering (DMLS) titanium frameworks in hybrid denture prostheses. A structured PICO analysis and a review of ten publications were used to compare titanium frameworks for hybrid dentures made through milling, DMLS, and CAD-CAM milling. Prosthesis success, bone loss, patient satisfaction, framework fit, and biofilm adhesion were among the outcome indicators. The inclusion criteria included comparisons between DMLS and milled titanium frameworks, investigations of hybrid dentures with metal frameworks, and various study designs. The exclusion criteria included reviews, case reports, non-comparative research, and studies unrelated to hybrid dentures. A comprehensive search was performed up to December 2023 across PubMed, PubMed Central, Cochrane Library, Scopus, and Google Scholar, using terms such as CAD-CAM, dental implantation, dental prosthesis, bone loss, damaged maxilla/mandible, implant framework, and bone volume. Ten studies were available for the final analysis. These studies shed light on milled titanium framework’s relative effectiveness and characteristics versus DMLS for implant-supported hybrid dentures. This narrative analysis clarifies the critical roles of the CAD-CAM and DMLS frameworks in implant-supported hybrid dentures. Despite the significant benefits of both of these technologies, it is evident that more investigation is required to identify the optimal framework option for specific clinical scenarios, highlighting the importance of continuing research in this field.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthodontics and Restorative Dentistry, College of Dentistry, Majmaah University, Al Majmaah 11952, Saudi Arabia

References (63)

Show source-provided references
1. Computer-Assisted Design/Computer-Assisted Manufacturing Systems: A Revolution in Restorative Dentistry10.4103/0972-4052.164905 ↗
2. Marginal Adaptation and CAD-CAM Technology: A Systematic Review of Restorative Material and Fabrication Techniques10.1016/j.prosdent.2017.07.001 ↗
3. Marginal Adaptation of Provisional CAD/CAM Restorations Fabricated Using Various Simulated Digital Cement Space Settings10.11607/jomi.6271 ↗
4. CAD-CAM Removable Complete Dentures: A Systematic Review and Meta-Analysis of Trueness of Fit, Biocompatibility, Mechanical Properties, Surface Charac-Teristics, Color Stability, Time-Cost Analysis, Clinical and Patient-Reported Outcomes10.1016/j.jdent.2021.103777 ↗
5. Biocompatibility of Advanced Manufactured Titanium Implants—A Review10.3390/ma7128168 ↗
6. Biocompatibility of Various Dental Materials in Contemporary Dentistry: A Narrative Insight10.1111/j.2041-1626.2012.00140.x ↗
7. Alhallak, K., Hagi-Pavli, E., and Nankali, A. (2023). A Review on Clinical Use of CAD/CAM and 3D Printed Dentures. Br. Dent. J., 1–5.10.1038/s41415-022-5401-5 ↗
8. CAD/CAM complete dentures: A review of two commercial fabrication systems
9. A Comparison of Fit of CNC-Milled Titanium and Zirconia Frameworks to Implants10.1111/j.1708-8208.2010.00334.x ↗
10. The Influence of the Addition of Titanium Oxide Nanotubes on the Properties of 3D Printed Denture Base Materials10.1111/jerd.13299 ↗
11. CNC-Milled Titanium Frameworks Supported by Implants in the Edentulous Jaw: A 10-Year Comparative Clinical Study10.1111/j.1708-8208.2009.00232.x ↗
12. Comments Regarding: Cooper LF, Stanford C, Feine J, McGuire M. Prospective Assessment of CAD-CAM Zirconia Abutment and Lithium Disilicate Crown Restorations: 2.4 Year Results10.1016/j.prosdent.2017.02.013 ↗
13. Evaluation and Comparison of Vertical Marginal Fit of Three Different Types of Multiunit Screw-Retained Framework Fabricated for an Implant-Supported Prosthesis—An in Vitro Study10.4103/jips.jips_28_22 ↗
14. The Effect of Framework Fabrication Technique on the Fit Accuracy of Full Arch Screw Retained Implant Supported Prostheses10.1016/j.sdentj.2022.03.006 ↗
15. Implant-Abutment Discrepancy Before and After Acrylic Resin Veneering of Complete-Arch Titanium Frameworks Manufactured Using Milling and Electron Beam Melting Technologies10.1111/jopr.13422 ↗
16. Comparison of Marginal and Internal Fit of Different CAD/CAM Copings
17. A Comparative Study of the Biological and Prosthetic Complications of CAD/CAM Zirconia and Conventional Cast Implant Supported Hybrid Prostheses10.21608/adjc.2023.183648.1222 ↗
18. Al-humood, H., Alfaraj, A., Yang, C.-C., Levon, J., Chu, T.-M.G., and Lin, W.-S. (2023). Marginal Fit, Mechanical Properties, and Esthetic Outcomes of CAD/CAM Interim Fixed Dental Prostheses (FDPs): A Systematic Review. Materials, 16.10.3390/ma16051996 ↗
19. CAD-CAM Implant-Supported Fixed Complete Dental Prosthesis with Titanium Milled Molars: A Clinical Report10.1016/j.prosdent.2016.07.029 ↗
20. Failures and Complications in 127 Consecutively Placed Fixed Partial Prostheses Supported by Brånemark Implants: From Prosthetic Treatment to First Annual Checkup
21. Rexhepi, I., Santilli, M., D’Addazio, G., Tafuri, G., Manciocchi, E., Caputi, S., and Sinjari, B. (2023). Clinical Applications and Mechanical Properties of CAD-CAM Materials in Restorative and Prosthetic Dentistry: A Systematic Review. J. Funct. Biomater., 14.10.20944/preprints202307.1226.v1 ↗
22. Early Laser-Welded Titanium Frameworks Supported by Implants in the Edentulous Mandible: A 15-Year Comparative Follow-Up Study10.1111/j.1708-8208.2008.00119.x ↗
23. Marginal Discrepancy of Noble Metal-Ceramic Fixed Dental Prosthesis Frameworks Fabricated by Conventional and Digital Technologies10.1016/j.prosdent.2017.08.012 ↗
24. Clinical Experiences with Laser-Welded Titanium Frameworks Supported by Implants in the Edentulous Mandible: A 10-Year Follow-Up Study10.1111/j.1708-8208.2006.00020.x ↗
25. Laser-Welded Titanium Frameworks for Fixed Prostheses Supported by Osseointegrated Implants: A 2-Year Multicenter Study Report
26. Three-Dimensional Distortion of Gold Alloy Castings and Welded Titanium Frameworks. Measurements of the Precision of Fit between Completed Implant Prostheses and the Master Casts in Routine Edentulous Situations10.1111/j.1365-2842.1995.tb01049.x ↗
27. Fabrication of Titanium Alloy Frameworks for Complete Dentures by Selective Laser Melting10.1016/j.prosdent.2014.06.017 ↗
28. Biomechanical Behavior of CAD/CAM Cobalt-Chromium and Zirconia Full-Arch Fixed Prostheses10.4047/jap.2020.12.6.329 ↗
29. Papathanasiou, I., Kamposiora, P., Papavasiliou, G., and Ferrari, M. (2020). The Use of PEEK in Digital Prosthodontics: A Narrative Review. BMC Oral. Health, 20.10.1186/s12903-020-01202-7 ↗
30. Mourad, K.E., Rashed, N.H.A.H., Altonbary, G.Y., and Fattah Hegazy, S.A. (2024). Five years of radiographic evaluation for the peri-implant bone changes of all-on-four implant prostheses constructed from different framework materials using different digital construction techniques. BMC. Oral. Health., 24.10.1186/s12903-024-04642-7 ↗
31. CAD/CAM, Prosthetic Options in Rehabilitation of Compromised Ridges with Implants: A Scoping Review
32. CAD/CAM Fabrication of Definitive Implant Prostheses: A Digital Workflow from Planning to Implant Placement to Final Restoration
33. Implant-Supported Overdenture Manufactured Using CAD/CAM Techniques to Achieve Horizontal Path Insertion between the Primary and Secondary Structure: A Clinical Case Report10.4047/jap.2015.7.3.264 ↗
34. Current State of CAD/CAM Technology in Implant Dentistry
35. Incorporating an Artificially Synthesized Fluoride Complex into Urethane-Acrylate-Based 3D Printing Resin: Effects on Mechanical Properties, Cytotoxicity, Antimicrobial Actions, and Its Long-Term Fluoride-Releasing Properties10.1016/j.jdent.2024.105363 ↗
36. Laser welding of titanium in dentistry10.3109/00016358809004774 ↗
37. Digital Beading for a CAD-CAM Framework for an Implant-supported Overdenture: A Dental Technique10.1111/jopr.13695 ↗
38. Dimitrova, M., Vlahova, A., and Kazakova, R. (2024). Assessment of CAD/CAM Fabrication Technologies for Post and Core Restorations—A Narrative Review. Medicina, 60.10.20944/preprints202404.0552.v1 ↗
39. Titanium Investiment Casting Defects: A Metallographic Overview10.1007/s11837-006-0172-z ↗
40. Prevalence of Complications after the Oral Rehabilitation with Implant-Supported Hybrid Prostheses
41. Long-Term Treatment Outcomes in Edentulous Patients with Implant-Fixed Prostheses: The Toronto Study10.1016/j.prosdent.2004.09.017 ↗
42. Precision of CNC-Milled Titanium Frameworks for Implant Treatment in the Edentulous Jaw
43. Manufacturing of Metal Frameworks for Full-Arch Dental Restoration on Implants: A Comparison between Milling and a Novel Hybrid Technology10.1111/jopr.13067 ↗
44. Custom-Made 3D Printed Subperiosteal Titanium Implants for the Prosthetic Restoration of the Atrophic Posterior Mandible of Elderly Patients: A Case Series10.1186/s41205-019-0055-x ↗
45. In Vitro Comparative Study of Different Technologies for Metal Denture Framework Fabrication-Direct Metal Laser Sintering Machine Milling and Hybri Technology
46. Evaluation of Zirconium-Oxide-Based Ceramic Single-Unit Posterior Fixed Dental Prostheses (FDPs) Generated with Two CAD/CAM Systems Compared to Porcelain-Fused-to-Metal Single-Unit Posterior FDPs: A 5-Year Clinical Prospective Study10.1111/j.1532-849X.2011.00825.x ↗
47. Five-Year Results of a Prospective Randomised Controlled Clinical Trial of Posterior Computer-Aided Design–Computer-Aided Manufacturing ZrSiO4-Ceramic Crowns10.1111/joor.12075 ↗
48. Comparative Study of All-Ceramic Crowns Obtained from Conventional and Digital Impressions: Clinical Findings10.1007/s00784-018-2606-8 ↗
49. Three-Dimensional-Printed Malo Bridge: Digital Fixed Prosthesis for the Partially Edentulous Maxilla10.4103/ccd.ccd_456_20 ↗
50. Fit of Monolithic Multilayer Zirconia Fixed Partial Dentures Fabricated by Conventional versus Digital Impression: A Clinical and Laboratory Investigations10.1007/s00784-021-03845-4 ↗
51. BioHPP Fixed Hybrid Prosthesis versus BioHPP Bar Overdenture as Treatment Options for Mandibular Edentulous Ridge (Prosthetic Maintenance and Patients’ Satisfaction)10.21608/edj.2023.191453.2425 ↗
52. CAD/CAM vs Conventional Technique for Fabrication of Implant-Supported Frameworks: A Systematic Review and Meta-Analysis of In Vitro Studies10.11607/ijp.5616 ↗
53. Shaikh, S.A., Rai, P., Aldhuwayhi, S., Mallineni, S.K., Lekha, K., Joseph, A.M., Kumari, V.V., and Meshramkar, R. (2022). Comparative Evaluation of Stress Acting on Abutment, Bone, and Connector of Different Designs of Acid-Etched Resin-Bonded Fixed Partial Dentures: Finite Element Analysis. Front. Bioeng. Biotechnol., 10.10.3389/fbioe.2022.978067 ↗
54. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA
55. Treatment Planning of Implants in Posterior Quadrants10.1038/sj.bdj.4813766 ↗
56. Osseointegration and Its Experimental Background10.1016/S0022-3913(83)80101-2 ↗
57. A Comparison of the Accuracy of Fit of 2 Methods for Fabricating Implant-Prosthodontic Frameworks
58. Fracture behaviors of maxillary central incisors with flared root canals restored with CAD/CAM integrated glass fiber post-and-core10.4012/dmj.2017-394 ↗
59. Prosthodontic rehabilitation of a hypohydrotic ectodermal dysplasia patient with extracoronal attachments: A case report10.54276/JUPD.2021.1109 ↗
60. Pasang, T., Tavlovich, B., Yannay, O., Jackson, B., Fry, M., Tao, Y., Turangi, C., Wang, J.-C., Jiang, C.-P., and Sato, Y. (2021). Directionally-Dependent Mechanical Properties of Ti6Al4V Manufactured by Electron Beam Melting (EBM) and Selective Laser Melting (SLM). Materials, 14.10.3390/ma14133603 ↗
61. Effect of different finish line preparations on the marginal and internal adaptation of cobalt-chromium metal alloy copings fabricated by using CAD-CAM technology: A systematic review and meta-analysis10.1016/j.prosdent.2021.06.030 ↗
62. Marginal and Internal Fit of CAD-CAM Inlay/Onlay Restorations: A Systematic Review of in Vitro Studies10.1016/j.prosdent.2018.06.006 ↗
63. Accuracy of Removable Partial Denture Framework Fabricated by Casting with a 3D Printed Pattern and Selective Laser Sintering10.1016/j.jpor.2019.07.009 ↗