The Use of Functional Biomaterials in Aesthetic and Functional Restoration in Orbital Surgery
Source abstract
Abstract
The integration of functional biomaterials in oculoplastic and orbital surgery is a pivotal area where material science and clinical practice converge. This review, encompassing primary research from 2015 to 2023, delves into the use of biomaterials in two key areas: the reconstruction of orbital floor fractures and the development of implants and prostheses for anophthalmic sockets post-eye removal. The discussion begins with an analysis of orbital floor injuries, including their pathophysiology and treatment modalities. It is noted that titanium mesh remains the gold standard for orbital floor repair due to its effectiveness. The review then examines the array of materials used for orbital implants and prostheses, highlighting the dependence on surgeon preference and experience, as there are currently no definitive guidelines. While recent innovations in biomaterials show promise, the review underscores the need for more clinical data before these new materials can be widely adopted in clinical settings. The review advocates for an interdisciplinary approach in orbital surgery, emphasizing patient-centered care and the potential of biomaterials to significantly enhance patient outcomes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Facial Trauma and Fracture Management · Ocular Disorders and Treatments · Facial Rejuvenation and Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrook, QC J1G 2E8, Canada
Faculty of Medicine, Queen’s University, Kingston, ON K7L 3N6, Canada
Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, QC H3A 1G1, Canada
References (100+)
Show source-provided references
1. Clinical Recommendations for Repair of Isolated Orbital Floor Fractures: An Evidence-Based Analysis1 1The Author Has No Financial Interest in Any of the Materials Discussed10.1016/S0161-6420(02)01057-6 ↗
2. Blow-Out Fracture of the Orbit*: Mechanism and Correction of Internal Orbital Fracture10.1016/0002-9394(76)90774-1 ↗
3. Orbital Rim Trauma Causing a Blowout Fracture10.1097/00006534-198406000-00022 ↗
4. An Investigation into the Mechanism of Orbital Blowout Fractures10.1054/bjps.1999.3194 ↗
5. Mechanisms of Orbital Floor Fractures: A Clinical, Experimental, and Theoretical Study10.1097/00002341-200005000-00005 ↗
6. Orbital “Blowout” Fractures: Time for a New Paradigm10.1016/j.ophtha.2018.02.014 ↗
7. (2023, August 04). 2020–2021 BCSC Basic and Clinical Science CourseTM. Available online: https://www.aao.org/education/bcscsnippetdetail.aspx?id=b879ee48-8b97-4985-a5b9-af8f9125d2c6.
8. Functional Outcome after Surgical Treatment of Orbital Floor Fractures10.1007/s00784-011-0609-9 ↗
9. The Transconjunctival Approach for Treating Orbital Trauma10.1016/0278-2391(91)90174-K ↗
10. Use of the Preseptal Transconjunctival Approach in Orbit Reconstruction Surgery10.1053/joms.2001.20997 ↗
11. A Comparative Study of Orbital Blow out Fracture Repair, Using Autogenous Bone Graft and Alloplastic Materials10.1007/s12070-019-01724-9 ↗
12. Reconstruction of Orbital Blow-Out Fracture by Titanium Mesh Versus Autogenous Bone
13. Autogenous Grafts for Orbital Floor Reconstruction: A Review
14. Comparison of Nasoseptal Cartilage Graft versus Titanium Mesh in Reconstruction of Pure Orbital Blowout Fractures10.1097/SCS.0000000000007499 ↗
15. Assessment of the Efficacy of Auricular Conchal Cartilage Graft in Repairing Orbital FLoor Fractures and Its Effect on Diplopia: A Nonrandomized Clinical Trial10.1097/MS9.0000000000000980 ↗
16. Repairing Orbital Floor Fracture with Autologous Nasal Septal Cartilage by Using Endoscope through Transoral Maxillary Sinus10.29271/jcpsp.2022.10.1372 ↗
17. Application of One Piece Autologous Rib Cartilage Graft in Hollow Space of Complete Naso-Ethmoid Orbital Fracture10.1097/SCS.0000000000008233 ↗
18. Evaluation the Outcomes of Using Iliac Bone Graft for Reconstruction of Traumatic Orbital Floor Fractures
19. Orbital Floor Reconstruction with Lyophilized Dura10.1016/0278-2391(88)90180-2 ↗
20. Orbital Floor Repair with Lyophilized Porcine Dermis10.1016/0030-4220(88)90158-2 ↗
21. Use of Demineralized Bone Sheets in Reconstruction of Orbital Floor Trap Door Fracture
22. Early Surgical Intervention for Orbital Floor Fractures: A Clinical Evaluation of Lyophilized Dura and Cartilage Reconstruction10.1016/0278-2391(92)90049-6 ↗
23. Reconstruction of Orbital Fractures with Dehydrated Human Dura Mater10.1053/joms.2000.18266 ↗
24. Clinical Evaluation of Using Cortical Lamina Xenograft in Reconstruction of Orbital Floor
25. Combination of Absorbable Mesh and Demineralized Bone Matrix in Orbital Wall Fracture for Preventing Herniation of Orbit10.1097/SCS.0000000000000796 ↗
26. Alloplastic Reconstruction of Orbital Floor Fractures: A Systematic Review and Pooled Outcomes Analysis10.1007/s00238-019-01614-x ↗
27. Reconstruction of Orbital Floor Fractures with Titanium Micromesh: Our Experience10.1007/s12663-020-01407-x ↗
28. Marella, V., Khetrapal, P., Gangasani, A., Bhanot, R., and Uppal, A. (2021). Titanium Mesh versus Medpor Implant in Orbital Floor Reconstructions: A Comparative Study. J. Pharm. Bioallied Sci., 13.10.4103/jpbs.JPBS_553_20 ↗
29. Outcome of Precontoured Titanium Mesh in the Reconstruction of Orbital Blowout Fractures10.1055/s-0043-1761597 ↗
30. Orbital Implants in Orbital Fracture Reconstruction: A Ten-Year Series10.1177/1943387520939032 ↗
31. Materials to Facilitate Orbital Reconstruction and Soft Tissue Filling in Posttraumatic Orbital Deformaties10.20517/2347-9264.2015.122 ↗
32. Precision of Posttraumatic Primary Orbital Reconstruction Using Individually Bent Titanium Mesh with and without Navigation: A Retrospective Study10.1186/1746-160X-9-18 ↗
33. A Systematic Approach for Making 3D-Printed Patient-Specific Implants for Craniomaxillofacial Reconstruction10.1016/j.eng.2020.02.019 ↗
34. Orbital Fracture Reconstruction Using Prebent, Anatomic Titanium Plates: Technical Tips to Avoid Complications10.1097/SCS.0000000000004563 ↗
35. Restoration of the Inferomedial Orbital Strut Using a Standardized Three-dimensional Printing Implant10.1111/joa.13136 ↗
36. Application of the Three-Dimensionally Printed Biodegradable Polycaprolactone (PCL) Mesh in Repair of Orbital Wall Fractures10.1016/j.jcms.2019.03.009 ↗
37. Late Reconstruction of Post-Traumatic Enophthalmos and Hypoglobus Using Three-Dimensional Implants: A Case Series10.7181/acfs.2022.00850 ↗
38. Orbital Wall Reconstruction with Two-Piece Puzzle 3D Printed Implants: Technical Note10.1055/s-0035-1563392 ↗
39. Custom Three-Dimensional Printed Orbital Plate Composed of Two Joined Parts with Variable Thickness for a Large Orbital Floor Reconstruction after Post-Traumatic Zygomatic Fixation10.1016/j.bjoms.2020.08.082 ↗
40. Correction of a Posttraumatic Orbital Deformity Using Three-Dimensional Modeling, Virtual Surgical Planning with Computer-Assisted Design, and Three-Dimensional Printing of Custom Implants10.1055/s-0037-1601432 ↗
41. Theoretical Model of Pediatric Orbital Trapdoor Fractures and Provisional Personalized 3D Printing-Assisted Surgical Solution
42. Endoscopically Assisted Computer-Guided Repair of Internal Orbital Floor Fractures: An Updated Protocol for Minimally Invasive Management10.1016/j.jcms.2019.11.005 ↗
43. A Novel Method of Orbital Floor Reconstruction Using Virtual Planning, 3-Dimensional Printing, and Autologous Bone10.1016/j.joms.2016.03.044 ↗
44. Virtual Surgical Planning and Three-Dimensional Printing for the Treatment of Comminuted Zygomaticomaxillary Complex Fracture10.1016/j.jormas.2020.05.009 ↗
45. Application of Three-Dimensional Printing Technology in the Orbital Blowout Fracture Reconstruction10.1097/SCS.0000000000005574 ↗
46. Sigron, G.R., Rüedi, N., Chammartin, F., Meyer, S., Msallem, B., Kunz, C., and Thieringer, F.M. (2020). Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and “Hybrid” Patient-Specific Implants. J. Clin. Med., 9.10.3390/jcm9051579 ↗
47. The Accuracy of Patient Specific Implant Prebented with 3D-Printed Rapid Prototype Model for Orbital Wall Reconstruction10.1016/j.jcms.2017.03.010 ↗
48. Customized Orbital Wall Reconstruction Using Three-Dimensionally Printed Rapid Prototype Model in Patients With Orbital Wall Fracture10.1097/SCS.0000000000003195 ↗
49. Implantation of Customized, Preshaped Implant for Orbital Fractures with the Aid of Three-Dimensional Printing10.4103/meajo.MEAJO_262_16 ↗
50. Carbonated Apatite and Hydroxyapatite in Craniofacial Reconstruction10.1001/archfaci.5.5.379 ↗
51. Hydroxyapatite for Biomedical Applications: A Short Overview10.3390/ceramics4040039 ↗
52. Lemke, B.N., and Kikkawa, D.O. (1999). Repair of Orbital Floor Fractures with Hydroxyapatite Block Scaffolding, LWW.10.1097/00002341-199905000-00004 ↗
53. Bioceramic Orbital Plate Implant
54. Analysis of the Postoperative Outcome in 405 Cases of Orbital Fracture Using 2 Synthetic Orbital Implants10.1097/01.sap.0000199173.73610.bc ↗
55. Orbital Floor Reconstruction: A Case for Silicone. A 12 Year Experience10.1016/j.bjps.2009.05.057 ↗
56. The Wayward Implant: Orbital Silicone Plate Extrusion Associated with Squamous Epithelial Downgrowth and Infection10.1076/orbi.21.2.149.7190 ↗
57. Symptomatic Cystic Lesions as Late Post-Operative Complications of Silicone Implantation for Orbital Wall Fracture Reconstruction: A Long-Term Follow-up Study10.1016/j.bjps.2019.09.011 ↗
58. Delayed Implant Infection with Cutibacterium Acnes (Propionibacterium Acnes) 30 Years after Silicone Sheet Orbital Floor Implant10.1080/01676830.2019.1605613 ↗
59. Experimental Evaluation of Expanded Polytetrafluoroethylene for Reconstruction of Orbital Floor Defects10.1016/0278-2391(94)90175-9 ↗
60. The Efficacy of Gore-Tex vs. Hydroxyapatite and Bone Graft in Reconstruction of Orbital Floor Defects10.1007/s00238-002-0448-7 ↗
61. Efficacy and Safety of Expanded Polytetrafluoroethylene Implantation in the Correction of Long-Term Posttraumatic Enophthalmos10.1097/PRS.0000000000010440 ↗
62. Complex Fistula Formations After Orbital Fracture Repair With Teflon: A Review of 3 Case Reports10.1097/SAP.0000000000002542 ↗
63. Lee, D.J., Kwon, J., Kim, Y.-I., Kwon, Y.H., Min, S., and Shin, H.W. (2020). Coating Medpor® Implant with Tissue-Engineered Elastic Cartilage. J. Funct. Biomater., 11.10.3390/jfb11020034 ↗
64. Porous Polyethylene Implants in Orbital Floor Reconstruction: Outcome and Complications10.5505/ktd.2022.97355 ↗
65. Implants and Spacers for Paralytic Ectropion: Literature Review and Assessment of a Thin-Profile Porous Polyethylene Implant10.4103/ijo.IJO_885_22 ↗
66. Efficacy of Iliac Crest vs. Medpor in Orbital Floor Reconstruction10.1007/s12663-010-0047-2 ↗
67. Late-Onset Orbital Infection Following Blowout Fracture Repair with a Medpor Titan Implant: A Case Report
68. Chocolate Cysts Associated With Porous Polyethylene Orbital Implants10.1097/IOP.0000000000001797 ↗
69. Reconstruction of Orbital Floor Fractures Using a Porous Polyethylene Implant: Outcomes in the Early, Intermediate and Late Postoperative Periods
70. Atraumatic Delayed Orbital Hematoma Sixteen Years after Orbital Floor Fracture Repair with Porous Polyethylene Implant10.1097/SCS.0000000000005139 ↗
71. Application of Three-Dimensional Printing Technology in Orbital Floor Fracture Reconstruction10.1016/j.tcr.2018.09.006 ↗
72. Orbital Fracture Repair Outcomes with Preformed Titanium Mesh Implants and Comparison to Porous Polyethylene Coated Titanium Sheets10.1016/j.jcms.2016.11.020 ↗
73. Orbital Floor Reconstruction10.1097/SCS.0b013e3181e57241 ↗
74. Orbital Bony Reconstruction With Presized and Precontoured Porous Polyethylene–Titanium Implants10.1097/IOP.0000000000001829 ↗
75. Downes, R.N., Vardy, S., Tanner, K.E., and Bonfield, W. (1991). Bioceramics, Elsevier.
76. Wraparound Nylon Foil Implant for Isolated Orbital Floor Fractures10.1016/j.amjoto.2021.103229 ↗
77. Smooth Nylon Foil (SupraFOIL) Orbital Implants in Orbital Fractures: A Case Series of 181 Patients10.1097/IOP.0b013e31817e0fe0 ↗
78. Warfarin-Associated Delayed Orbital Hemorrhage after Orbital Fracture Repair with Smooth Nylon Foil Implant10.1080/01676830.2019.1639771 ↗
79. Orbital Inflammation in the Setting of a Nylon Foil Implant10.1080/01676830.2021.1918725 ↗
80. Biodegradable Implants for Orbital Wall Fracture Reconstruction10.7181/acfs.2020.00010 ↗
81. Treatment of Orbital Floor Fracture Using a Periosteum–Polymer Complex10.1016/j.jcms.2009.06.011 ↗
82. Use of Bioresorbable Implants for Orbital Fracture Reconstruction10.1136/bjophthalmol-2016-309330 ↗
83. A Comparative Study of 2 Implants Used to Repair Inferior Orbital Wall Bony Defects: Autogenous Bone Graft Versus Bioresorbable Poly-L/DL-Lactide [P(L/DL)LA 70/30] Plate10.1016/j.joms.2006.03.010 ↗
84. Repair of Orbital Floor Fractures Using Bioresorbable Poly-L/DL-Lactide Plates10.1001/archfaci.2010.91 ↗
85. Poly (L-Lactide) Implants in Repair of Defects of the Orbital Floor: An Animal Study10.1016/0278-2391(90)90487-M ↗
86. Poly(l-Lactide) Implants for Repair of Human Orbital Floor Defects: Clinical and Magnetic Resonance Imaging Evaluation of Long-Term Results10.1016/S0278-2391(96)90292-X ↗
87. Resorbable Polylactic Acid Polymer Plates in Repair of Blow-out Orbital Floor Fractures10.1177/1120672120928005 ↗
88. Intermediate Outcomes of Orbital Wall Reconstruction Using Different Alloplastic Materials: Which Is Ideal?10.1097/PRS.0000000000009554 ↗
89. Lactosorb Panel and Screws for Repair of Large Orbital Floor Defects10.1016/S1010-5182(97)80033-9 ↗
90. The Response of Cultured Bone Cells to Resorbable Polyglycolic Acid and Silicone Membranes for Use in Orbital Floor Fracture Repair10.1016/0267-6605(94)90014-0 ↗
91. Use of Copolymer Polylactic and Polyglycolic Acid Resorbable Plates in Repair of Orbital Floor Fractures10.1055/s-0034-1393697 ↗
92. Resorbable Plate Fixation in Pediatric Craniofacial Surgery10.1097/00006534-199707000-00001 ↗
93. Use of Vicryl (Polyglactin-910) Mesh Implant for Repair of Orbital Floor Fracture Causing Diplopia: A Study of 28 Patients over 5 Years10.1097/00002341-199309000-00004 ↗
94. Reconstruction of the Orbital Floor with Polydioxanone: A Long-Term Clinical Survey of up to 12 Years10.1016/j.bjoms.2015.05.010 ↗
95. Comparison of Collagen Membranes and Polydioxanone for Reconstruction of the Orbital Floor after Fractures10.1097/SCS.0b013e3181e62c5f ↗
96. Orbital Floor Reconstruction with Resorbable Polydioxanone Implants10.1097/SCS.0b013e3182413edc ↗
97. Reconstruction of Orbital Floor with Polydioxanone Plate10.1016/S0901-5027(05)80712-X ↗
98. Orbital Floor Reconstruction with an Alloplastic Resorbable Polydioxanone Sheet10.1054/ijom.2001.0219 ↗
99. Effectiveness of Operative Treatment of Internal Orbital Wall Fracture with Polydioxanone Implant10.1054/ijom.2001.0067 ↗
100. Reconstruction of Orbital Floor Fracture with Polyglactin 910/Polydioxanon Patch (Ethisorb): A Retrospective Study10.1016/j.joms.2004.11.013 ↗