Biomaterials and Clinical Applications of Customized Healing Abutment—A Narrative Review
Source abstract
Abstract
Customized healing abutments have been introduced in clinical practice along with implant surgery to preserve or create natural-appearing hard and soft tissue around the implant. This provides the benefits of reducing the overall treatment time by eliminating the second stage and reducing the elapsed time of the fabrication of the final prostheses. This article aims to review the types and properties of materials used for the fabrication of customized healing abutments and their clinical applications. Articles published in English on customized healing abutments were searched in Google Scholar, PubMed/MEDLINE, ScienceDirect, and the Scopus databases up to August 2022. The relevant articles were selected and included in this literature review. Customized healing abutments can be fabricated from materials available for dental implants, including PEEK, PMMA, zirconia, resin composite, and titanium. All the materials can be used following both immediate and delayed implant placement. Each material provides different mechanical and biological properties that influence the peri-implant tissues. In conclusion, the studies have demonstrated promising outcomes for all the materials. However, further investigation comparing the effects of each material on peri-implant soft and hard tissues is required.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand
Funding
Faculty of Dentistry, Chiang Mai University, Thailand
References (100+)
Show source-provided references
1. Crestal Bone Stability around Implants with Horizontally Matching Connection after Soft Tissue Thickening: A Prospective Clinical Trial10.1111/cid.12155 ↗
2. Factors Affecting Soft and Hard Tissues Around Two-Piece Transmucosal Implants: A 3-Year Prospective Cohort Study10.11607/jomi.7778 ↗
3. Case report: Maintenance of gingival form following immediate implant placement—The custom-healing abutment
4. Accurate transfer of peri-implant soft tissue emergence profile from the provisional crown to the final prosthesis using an emergence profile cast10.1111/j.1708-8240.2007.00128.x ↗
5. Oh, K.C., Kim, J.-H., Woo, C.-W., and Moon, H.S. (2019). Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement. J. Clin. Med., 8.10.3390/jcm8040490 ↗
6. Misch, C.E. (1993). Contemporary Implant Dentistry, Mosby.
7. All-ceramic versus titanium-based implant supported restorations: Preliminary 12-months results from a randomized controlled trial10.4047/jap.2019.11.1.48 ↗
8. A modified implant healing abutment to optimize soft tissue contours: A case report10.1097/01.id.0000144510.66524.87 ↗
9. Teślak, M., Ziemlewski, A., Foltyn, I., Ordyniec-Kwaśnica, I., and Drogoszewska, B. (2021). Development of Custom Anatomic Healing Abutment Based on Cone-Beam Computer Tomography Measurement on Human Teeth Cross-Section. Materials, 14.10.3390/ma14164570 ↗
10. Customized provisional abutment and provisional restoration for an immediately-placed implant
11. Peri-implant soft tissue conditioning with provisional restorations in the esthetic zone: The dynamic compression technique10.11607/prd.1268 ↗
12. Immediate placement and provisionalization of maxillary anterior single implants: 1-year prospective study
13. Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year10.1034/j.1600-0501.2003.140207.x ↗
14. Meng, H.-W., Chien, E.Y., and Chien, H.-H. (2021). Immediate Implant Placement and Provisionalization in the Esthetic Zone: A 6.5-Year Follow-Up and Literature Review. Case Rep. Dent., 2021.10.1155/2021/4290193 ↗
15. Prospective evaluation of immediate and delayed provisional single tooth restorations10.1016/j.joms.2009.07.009 ↗
16. Ionescu, R.N., Totan, A.R., Imre, M.M., Țâncu, A.M.C., Pantea, M., Butucescu, M., and Farcașiu, A.T. (2022). Prosthetic Materials Used for Implant-Supported Restorations and Their Biochemical Oral Interactions: A Narrative Review. Materials, 15.10.3390/ma15031016 ↗
17. Digital planning of a customized CAD-CAM healing abutment for soft tissue conditioning at the time of implant placement: A different digital and clinical perspective in molar implant rehabilitation
18. Immediate implant placement combining socket seal abutment and peri-implant socket filling: A prospective case series10.1111/clr.13852 ↗
19. Comparing the Clinical Outcome of Peri-implant Hard and Soft Tissue Treated with Immediate Individualized CAD/CAM Healing Abutments and Conventional Healing Abutments for Single-Tooth Implants in Esthetic Areas Over 12 Months: A Randomized Clinical Trial10.11607/jomi.8823 ↗
20. Fabrication of a CAD-CAM custom healing abutment guided by a conventional dental radiograph for delayed loaded dental implants: A dental technique10.1016/j.prosdent.2020.09.022 ↗
21. Use of CAD/CAM Healing Abutment Immediately After Dental Implant Placement for the Non-Esthetic Zone: A Guided Soft Tissue Healing Technique10.1563/aaid-joi-D-14-00228 ↗
22. Digitalized CAD/CAM protocol for the fabrication of customized sealing socket healing abutments in immediate implants in molar sites
23. Guided Immediate Implant Placement with Wound Closure by Computer-Aided Design/Computer-Assisted Manufacture Sealing Socket Abutment: Case Report10.11607/jomi.4770 ↗
24. Sealing Socket Abutments (SSAs) in Molar Immediate Implants with a Digitalized CAD/CAM Protocol: Soft Tissue Contour Changes and Radiographic Outcomes After 2 Years10.11607/prd.4579 ↗
25. A Workflow to Design and Fabricate a Customized Healing Abutment From a Dynamic Navigation Virtual Treatment Plan
26. A digital approach for one-step formation of the supra-implant emergence profile with an individualized CAD/CAM healing abutment10.1016/j.jpor.2016.01.005 ↗
27. Custom CAD-CAM healing abutment and impression coping milled from a poly(methyl methacrylate) block and bonded to a titanium insert10.1016/j.prosdent.2016.03.026 ↗
28. Rehabilitation of Anterior Tooth Loss with Immediate Implant and Preservation of Gingival Aesthetics with Use of Vertical Extraction System and Customized Healing Abutment made by CAD-CAM Technology: Case Report
29. Customized CAD-CAM healing abutment for delayed loaded implants10.1016/j.prosdent.2016.01.024 ↗
30. A New Concept in Maintaining the Emergence Profile in Immediate Posterior Implant Placement: The Anatomic Harmony Abutment10.1016/j.joms.2016.06.184 ↗
31. Suphangul, S., Rokaya, D., Kanchanasobhana, C., Rungsiyakull, P., and Chaijareenont, P. (2022). PEEK Biomaterial in Long-Term Provisional Implant Restorations: A Review. J. Funct. Biomater., 13.10.3390/jfb13020033 ↗
32. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
33. Papathanasiou, I., Kamposiora, P., Papavasiliou, G., and Ferrari, M. (2020). The use of PEEK in digital prosthodontics: A narrative review. BMC Oral Health, 20.10.1186/s12903-020-01202-7 ↗
34. Beretta, M., Poli, P.P., Pieriboni, S., Tansella, S., Manfredini, M., Cicciù, M., and Maiorana, C. (2019). Peri-Implant Soft Tissue Conditioning by Means of Customized Healing Abutment: A Randomized Controlled Clinical Trial. Materials, 12.10.3390/ma12183041 ↗
35. Peri-implant tissue management after immediate implant placement using a customized healing abutment10.1111/jerd.12512 ↗
36. Clinical application of the customizable PEEK healing abutment. A case report10.46875/jmd.v10i1.42 ↗
37. Comparison of the Bond Strength of Composite Resin to Zirconia and Composite Resin to Polyether Ether Ketone: An In Vitro Study10.4103/jpbs.JPBS_147_20 ↗
38. Grumezescu, V., and Grumezescu, A.M. (2019). Chapter 8—Thermoset Polymethacrylate-Based Materials for Dental Applications, Elsevier.
39. Ronald, L., Sakaguchi, J.L.F., and John, M. (2019). Powers, Craig’s Restorative Dental Materials, Elsevier. [14th ed.].
40. Zafar, M.S. (2020). Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update. Polymers, 12.10.3390/polym12102299 ↗
41. Cytotoxicity of denture base acrylic resins: A literature review10.1016/S0022-3913(03)00349-4 ↗
42. The Influence of Saliva pH on the Fracture Resistance of Three Complete Denture Base Acrylic Resins
43. CAD/CAM milled complete removable dental prostheses: An in vitro evaluation of biocompatibility, mechanical properties, and surface roughness10.4012/dmj.2017-207 ↗
44. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: An in vitro evaluation of trueness10.1016/j.prosdent.2018.09.001 ↗
45. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers
46. Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA-based polymers used for digital 3D complete dentures
47. A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA)10.1111/jopr.13033 ↗
48. Zirconia as a Dental Biomaterial10.3390/ma8084978 ↗
49. Jitwirachot, K., Rungsiyakull, P., Holloway, J.A., and Jia-Mahasap, W. (2022). Wear Behavior of Different Generations of Zirconia: Present Literature. Int. J. Dent., 2022.10.1155/2022/9341616 ↗
50. Wear of various restorative materials against 5Y-ZP zirconia
51. Bona, A.D. (2009). Bonding to Ceramics: Scientific Evidences for Clinical Dentistry, Editoria Artes Medicas Ltda.
52. Zirconia Use in Dentistry-Manufacturing and Properties
53. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing10.1016/j.dental.2004.07.013 ↗
54. Zhou, X., Huang, X., Li, M., Peng, X., Wang, S., Zhou, X., and Cheng, L. (2019). Development and status of resin composite as dental restorative materials. J. Appl. Polym. Sci., 136.10.1002/app.48180 ↗
55. Cho, K., Rajan, G., Farrar, P., Prentice, L., and Prusty, B.G. (2021). Dental resin composites: A review on materials to product realizations. Compos. Part B Eng., 230.10.1016/j.compositesb.2021.109495 ↗
56. Development and capture of soft tissue contours at time of implant placement10.1016/j.prosdent.2016.09.028 ↗
57. A Customized Healing Abutment for Immediate and Delayed Implant Cases
58. Fatigue resistance and failure mode of CAD/CAM composite resin implant abutments restored with type III composite resin and porcelain veneers10.1111/j.1600-0501.2010.02103.x ↗
59. Fatigue resistance and failure mode of novel-design anterior single-tooth implant restorations: Influence of material selection for type III veneers bonded to zirconia abutments10.1111/j.1600-0501.2010.02012.x ↗
60. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone10.1590/1807-3107BOR-2014.vol28.0028 ↗
61. Binary titanium alloys as dental implant materials-a review10.1093/rb/rbx027 ↗
62. Titanium Alloys for Dental Implants: A Review10.3390/prosthesis2020011 ↗
63. Titanium as a Reconstruction and Implant Material in Dentistry: Advantages and Pitfalls10.3390/ma5091528 ↗
64. Biofilm formation on the surface of modern implant abutment materials10.1111/clr.12454 ↗
65. Morphogenesis of the peri-implant mucosa: An experimental study in dogs10.1111/j.1600-0501.2006.01380.x ↗
66. Influence of different restorative materials on the stress distribution in dental implants
67. Effect of Different Customized Abutment Types on Stress Distribution in Implant-Supported Single Crown: A 3D Finite Element Analysis10.1111/jopr.13530 ↗
68. Biomechanical rigidity of an all-polyetheretherketone anterior thoracolumbar spinal reconstruction construct: An in vitro corpectomy model10.1016/j.spinee.2008.11.012 ↗
69. Hada, T., Kanazawa, M., Iwaki, M., Katheng, A., and Minakuchi, S. (2021). Comparison of Mechanical Properties of PMMA Disks for Digitally Designed Dentures. Polymers, 13.10.3390/polym13111745 ↗
70. Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials10.1111/j.1600-0722.2008.00551.x ↗
71. Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging10.11607/jomi.7036 ↗
72. Can polylactic acid be a CAD/CAM material for provisional crown restorations in terms of fit and fracture strength?10.4012/dmj.2020-232 ↗
73. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns10.1590/1678-775720150451 ↗
74. Asiri, A.M., and Inamuddin, M.A. (2019). 9-Nanocomposite Restorative Materials for Dental Caries Management. Applications of Nanocomposite Materials in Dentistry, Woodhead Publishing.
75. Fracture Toughness, Flexural Strength, and Flexural Modulus of New CAD/CAM Resin Composite Blocks10.1111/jopr.13123 ↗
76. Early Healing of Immediate Implants Connected With Two Types of Healing Abutments: A Prospective Cohort Study10.1097/ID.0000000000000809 ↗
77. Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour10.1016/S0928-4931(03)00033-X ↗
78. Guided gingival fibroblast attachment to titanium surfaces: An in vitro study10.1111/jcpe.12025 ↗
79. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature10.1016/S0109-5641(97)80038-3 ↗
80. The influence of surface topography of ceramic abutments on the attachment and proliferation of human oral fibroblasts10.1016/j.biomaterials.2004.02.037 ↗
81. Microbial retention on open food contact surfaces and implications for food contamination10.1016/S0065-2164(08)00408-5 ↗
82. Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion10.1016/j.jdent.2011.12.006 ↗
83. The Effect of a Polishing Protocol on the Surface Roughness of Zirconium Oxide10.11607/ijp.6686 ↗
84. Comparative evaluation of the wear resistance of two different implant abutment materials after cyclic loading—An in vitro study10.4103/ccd.ccd_294_19 ↗
85. Surface roughness of high-performance polymers used for fixed implant-supported prostheses10.1016/j.prosdent.2020.11.029 ↗
86. Surface roughness analysis of prepolymerized CAD/CAM dental acrylic resins following combined surface treatments
87. Herráez-Galindo, C., Rizo-Gorrita, M., Luna-Oliva, I., Serrera-Figallo, M.-Á., Castillo-Oyagüe, R., and Torres-Lagares, D. (2019). In vitro Comparative Study of Fibroblastic Behaviour on Polymethacrylate (PMMA) and Lithium Disilicate Polymer Surfaces. Polymers, 11.10.3390/polym11040744 ↗
88. Evaluation of Surface Roughness of Different Direct Resin-based Composites10.4103/jispcd.JISPCD_72_17 ↗
89. Nithya, K., Sridevi, K., Keerthi, V., and Ravishankar, P. (2020). Evaluation of Surface Roughness, Hardness, and Gloss of Composites After Three Different Finishing and Polishing Techniques: An In Vitro Study. Cureus, 12.10.7759/cureus.7037 ↗
90. Surface roughness of a resin composite10.1590/1981-863720160001000072929 ↗
91. The influence of surface free energy and surface roughness on early plaque formation: An in vivo study in man10.1111/j.1600-051X.1990.tb01077.x ↗
92. The Influence of Surface Free-energy on Planimetric Plaque Growth in Man10.1177/00220345890680050801 ↗
93. Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow-up10.1002/jbm.a.31310 ↗
94. Contact angle and surface free energy of experimental resin-based dental restorative materials after chewing simulation10.1016/j.dental.2014.03.009 ↗
95. Surface modification of zirconia with polydopamine to enhance fibroblast response and decrease bacterial activity in vitro: A potential technique for soft tissue engineering applications10.1016/j.colsurfb.2015.06.047 ↗
96. Zirconia surface modifications for implant dentistry10.1016/j.msec.2019.01.062 ↗
97. Thermal conduction of titanium implants under CO2 laser irradiation in vitro10.4103/2231-0746.95310 ↗
98. Pituru, S.M., Greabu, M., Totan, A., Imre, M., Pantea, M., Spinu, T., Tancu, A.M.C., Popoviciu, N.O., Stanescu, I.-I., and Ionescu, E. (2020). A Review on the Biocompatibility of PMMA-Based Dental Materials for Interim Prosthetic Restorations with a Glimpse into their Modern Manufacturing Techniques. Materials, 13.10.3390/ma13132894 ↗
99. Zirconia crowns-the new standard for single-visit dentistry?
100. Thermal Properties of Nonmetallic Restorative Materials10.1177/00220345720510040701 ↗