Show source-provided references
2. Relationship between prosthodontic status, caries, and periodontal disease in a geriatric population
3. Relationship between periodontics and prosthodontics: The two-way street
4. Avetisyan, A., Markaryan, M., Rokaya, D., Tovani-Palone, M.R., Zafar, M.S., Khurshid, Z., Vardanyan, A., and Heboyan, A. (2021). Characteristics of periodontal tissues in prosthetic treatment with fixed dental prostheses. Molecules, 26.
10.3390/molecules26051331 ↗5. Hao, Y., Huang, X., Zhou, X., Li, M., Ren, B., Peng, X., and Cheng, L. (2018). Influence of dental prosthesis and restorative materials interface on oral biofilms. Int. J. Mol. Sci., 19.
10.3390/ijms19103157 ↗6. Yin, X.J., Wei, B.Y., Ke, X.P., Zhang, T., Jiang, M.Y., Luo, X.Y., and Sun, H.Q. (2020). Correlation between clinical parameters of crown and gingival morphology of anterior teeth and periodontal biotypes. BMC Oral Health, 20.
10.1186/s12903-020-1040-x ↗7. The stomatognathic system in the elderly. Useful information for the medical practitioner
10.2147/CIA.S1596 ↗9. Prevalence of periodontal disease, its association with systemic diseases and prevention
13. Al-Odinee, N.M., Al-Hamzi, M., Al-Shami, I.Z., Madfa, A., Al-Kholani, A.I., and Al-Olofi, Y.M. (2020). Evaluation of the quality of fixed prosthesis impressions in private laboratories in a sample from yemen. BMC Oral Health, 20.
10.1186/s12903-020-01294-1 ↗15. Marginal and internal fit of fixed prosthodontic constructions: A literature review
16. Comparison of the marginal fit of different coping materials and designs produced by computer aided manufacturing systems
10.4012/dmj.2010-063 ↗18. Scanning electron microscope evaluation of vertical and horizontal discrepancy in cast copings for single-tooth implant-supported prostheses
10.1097/ID.0b013e318183621d ↗19. Marginal fit of heat-pressed vs. Cad/cam processed all-ceramic onlays using a milling unit prototype
10.2341/07-162 ↗22. Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by cerec inlab and hot-pressed techniques
10.1111/j.1532-849X.2011.00745.x ↗23. Marginal and internal fit of heat pressed versus cad/cam fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue
10.1016/j.jdent.2013.10.002 ↗24. In vitro evaluation of the marginal fit and internal adaptation of zirconia and lithium disilicate single crowns: Micro-ct comparison between different manufacturing procedures
10.2174/1874210601812010160 ↗25. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside cad/cam systems or the heat-pressing technique
10.1016/j.prosdent.2014.04.028 ↗26. Marginal and internal adaptation of ceramic crown restorations fabricated with cad/cam technology and the heat-press technique
10.1016/j.prosdent.2014.03.017 ↗28. Evaluation of fit and efficiency of cad/cam fabricated all-ceramic restorations based on direct and indirect digitalization: A double-blinded, randomized clinical trial
10.1007/s00784-015-1504-6 ↗30. Provisional restorations in restorative dentistry
31. Sorrentino, R., Navarra, C.O., Di Lenarda, R., Breschi, L., Zarone, F., Cadenaro, M., and Spagnuolo, G. (2019). Effects of finish line design and fatigue cyclic loading on phase transformation of zirconia dental ceramics: A qualitative micro-raman spectroscopic analysis. Materials, 12.
10.3390/ma12060863 ↗32. Cement selection in dental practice
35. Different pontic design for porcelain fused to metal fixed dental prosthesis: Contemporary guidelines and practice by general dental practitioners
10.4103/ejd.ejd_232_18 ↗38. Marginal adaptation of cad/cam all-ceramic crowns made by different impression methods: A literature review
10.1111/jopr.12800 ↗39. A follow-up study of up to 5 years of metal-ceramic crowns in maxillary central incisors for different gingival biotypes
10.11607/prd.2024 ↗40. Cad/cam techniques help in the rebuilding of ideal marginal gingiva contours of anterior maxillary teeth: A case report
10.1016/j.adaj.2017.03.003 ↗41. Surface modification of zirconia after laser irradiation
42. Changes in the parameters of gingival crevicular fluid in masticatory function restoration by various prosthodontic constructions
44. Histologic comparison of biologic width around teeth versus implant: The effect on bone preservation
48. Doornewaard, R., Bruyn, H., Matthys, C., Bronkhorst, E., Vandeweghe, S., and Vervaeke, S. (2020). The long-term effect of adapting the vertical position of implants on peri-implant health: A 5-year intra-subject comparison in the edentulous mandible including oral health-related quality of life. J. Clin. Med., 9.
10.3390/jcm9103320 ↗49. The intracrevicular restorative margin, the biologic width, and the maintenance of the gingival margin
55. Characteristics of periodontal biotype, its dimensions, associations and prevalence: A systematic review
10.1111/jcpe.12275 ↗57. Facial gingival tissue stability after connective tissue graft with single immediate tooth replacement in the esthetic zone: Consecutive case report
10.1016/j.joms.2009.07.004 ↗60. León-Martínez, R., Montiel-Company, J.M., Bellot-Arcís, C., Solá-Ruíz, M.F., Selva-Otaolaurruchi, E., and Agustín-Panadero, R. (2020). Periodontal behavior around teeth prepared with finishing line for restoration with fixed prostheses. A systematic review and meta-analysis. J. Clin. Med., 9.
10.3390/jcm9010249 ↗61. Prospective clinical study of zirconia full-coverage restorations on teeth prepared with biologically oriented preparation technique on gingival health: Results after two-year follow-up
10.2341/17-124-C ↗63. Biologically oriented preparation technique (bopt): A new approach for prosthetic restoration of periodontically healthy teeth
64. Interdisciplinary interface between fixed prosthodontics and periodontics
10.1111/prd.12189 ↗65. Inflammatory and immune pathways in the pathogenesis of periodontal disease
10.1111/prd.12002 ↗67. Destructive and protective roles of cytokines in periodontitis: A re-appraisal from host defense and tissue destruction viewpoints
10.1177/0022034510376402 ↗68. Zirconia as a dental implant abutment material: A systematic review
69. Fourteen-year evaluation of posterior zirconia-based three-unit fixed dental prostheses: A prospective clinical study of all ceramic prosthesis
10.1016/j.jdent.2020.103419 ↗70. Clinical efficacy and effects of cad/cam zirconia all-ceramic crown and metal-ceramic crown restoration on periodontal tissues
71. Influence of cad/cam all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes
10.1007/s00784-013-1098-9 ↗73. Oral hygiene and gingival health in patients with fixed prosthodontic appliances—A six month follow-up
74. Identification and consequences of distinct löe-silness gingival index examiner styles for the clinical assessment of gingivitis
10.1902/jop.2001.72.3.383 ↗75. The influence of fixed prostheses on periodontal health
77. Heboyan, A., Syed, A.U.Y., Rokaya, D., Cooper, P.R., Manrikyan, M., and Markaryan, M. (2020). Cytomorphometric analysis of inflammation dynamics in the periodontium following the use of fixed dental prostheses. Molecules, 25.
10.3390/molecules25204650 ↗78. Full coverage crowns and resin-bonded bridge combination for missing mandibular anterior teeth
82. Cytological analysis of the periodontal pocket in patients with aggressive periodontitis and chronic periodontitis
10.4103/0976-237X.142818 ↗86. Survival rate of teeth with periodontally hopeless prognosis after therapies with intentional replantation and perioprosthetic procedures—A study of case series for 5–12 years
10.1002/cre2.25 ↗87. Association between dental prosthesis and periodontal disease in a rural brazilian community
90. Eliaz, N. (2019). Corrosion of metallic biomaterials: A review. Materials, 12.
10.3390/ma12030407 ↗91. Corrosion resistance of graphene oxide/silver coatings on ni-ti alloy and expression of il-6 and il-8 in human oral fibroblasts
10.1038/s41598-020-60070-x ↗92. Surface adhesion properties and cytotoxicity of graphene oxide coatings and graphene oxide/silver nanocomposite coatings on biomedical niti alloy
10.1166/sam.2019.3536 ↗93. Graphene oxide/silver nanoparticle coating produced by electrophoretic deposition improved the mechanical and tribological properties of niti alloy for biomedical applications
10.1166/jnn.2019.16327 ↗94. Zirconia based dental ceramics: Structure, mechanical properties, biocompatibility and applications
10.1039/C6DT03484E ↗96. Effect of the cad/cam zirconia all-ceramic crown restoration on periodontal tissue
97. Gingival crevicular fluid as a periodontal diagnostic indicator- ii: Inflammatory mediators, host-response modifiers and chair side diagnostic aids
98. Characteristics of cellular composition of periodontal pockets
99. Neutrophil-mediated tissue injury in periodontal disease pathogenesis: Findings from localized aggressive periodontitis
10.1902/jop.2003.74.1.66 ↗100. Rizo-Gorrita, M., Luna-Oliva, I., Serrera-Figallo, M.-Á., Gutiérrez-Pérez, J.-L., and Torres-Lagares, D. (2018). Comparison of cytomorphometry and early cell response of human gingival fibroblast (hgfs) between zirconium and new zirconia-reinforced lithium silicate ceramics (zls). Int. J. Mol. Sci., 19.
10.3390/ijms19092718 ↗