journal article·2022-03-18Open access

Solution processed low power organic field-effect transistor bio-chemical sensor of high transconductance efficiency

Wei Tang, Ying Fu, Yukun Huang, Yuanzhe Li, Yawen Song, Xin Xi, Yude Yu, Yuezeng Su, Feng Yan, Xiaojun Guo

npj Flexible Electronics· Volume 6· Issue 1

Abstract

Abstract Developing organic field-effect transistor (OFET) biosensors for customizable detection of biomarkers for many diseases would provide a low-cost and convenient tool for both biological studies and clinical diagnosis. In this work, design principles of the OFET transducer for biosensors were derived to relate the signal-to-noise ratio (SNR) to the device-performance parameters. Steep subthreshold swing (SS), proper threshold voltage (Vth), good-enough bias-stress stability, and mechanical durability are shown to be the key prerequisites for realizing OFET bio-sensors of high transconductance efficiency (gm/ID) for large SNR. Combining a low trap-density channel and a high-k/low-k gate dielectric layer, low-temperature (<100 °C) solution-processed flexible OFETs can meet the performance requirements to maximize the gm/ID. An extended gate-structure OFET biosensor was further implemented for label-free detection of miR-21, achieving a detection limit below 10 pM with high selectivity at a low operation voltage (<1 V).
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Conducting polymers and applications · Nanowire Synthesis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Sakata, T. Biologically coupled gate field-effect transistors meet in vitro diagnostics. ACS Omega 4, 11852–11862 (2019).10.1021/acsomega.9b01629 ↗
2. Lee, M. Y., Lee, H. R., Park, C. H., Han, S. G. & Oh, J. H. Organic transistor-based chemical sensors for wearable bioelectronics. Acc. Chem. Res. 51, 2829–2838 (2018).10.1021/acs.accounts.8b00465 ↗
3. Syu, Y.-C., Hsu, W.-E. & Lin, C.-T. Review-field-effect transistor biosensing: devices and clinical applications. ECS J. Solid State Sci. Technol. 7, Q3196–Q3207 (2018).10.1149/2.0291807jss ↗
4. Zang, Y., Huang, D., Di, C. A. & Zhu, D. Device engineered organic transistors for flexible sensing applications. Adv. Mater. 28, 4549–4555 (2016).10.1002/adma.201505034 ↗
5. Magliulo, M., Manoli, K., Macchia, E., Palazzo, G. & Torsi, L. Tailoring functional interlayers in organic field-effect transistor biosensors. Adv. Mater. 27, 7528–7551 (2015).10.1002/adma.201403477 ↗
6. Khan, H. U. et al. In situ, label-free DNA detection using organic transistor sensors. Adv. Mater. 22, 4452–4456 (2010).10.1002/adma.201000790 ↗
7. Jiang, C., Cheng, X. & Nathan, A. Flexible ultralow-power sensor interfaces for E-skin. Proc. IEEE 107, 2084–2105 (2019).10.1109/JPROC.2019.2936105 ↗
8. Lai, S., Barbaro, M. & Bonfiglio, A. Tailoring the sensing performances of an OFET-based biosensor. Sens. Actuators B Chem. 233, 314–319 (2016).10.1016/j.snb.2016.04.095 ↗
9. Song, J. et al. Influence of bioreceptor layer structure on myelin basic protein detection using organic field effect transistor-based biosensors. Adv. Funct. Mater. 28, 1802605 (2018).10.1002/adfm.201802605 ↗
10. Minamiki, T. et al. Accurate and reproducible detection of proteins in water using an extended-gate type organic transistor biosensor. Appl. Phys. Lett. 104, 243703 (2014).10.1063/1.4883739 ↗
11. Minami, T. et al. Selective nitrate detection by an enzymatic sensor based on an extended-gate type organic field-effect transistor. Biosens. Bioelectron. 81, 87–91 (2016).10.1016/j.bios.2016.02.036 ↗
12. Wang, C., Dong, H., Jiang, L. & Hu, W. Organic semiconductor crystals. Chem. Soc. Rev. 47, 422–500 (2018).10.1039/C7CS00490G ↗
13. Gu, X., Shaw, L., Gu, K., Toney, M. F. & Bao, Z. The meniscus-guided deposition of semiconducting polymers. Nat. Commun. 9, 534 (2018).10.1038/s41467-018-02833-9 ↗
14. Moser, N., Rodriguez-Manzano, J., Lande, T. S. & Georgiou, P. A scalable ISFET sensing and memory array with sensor auto-calibration for on-chip real-time DNA detection. IEEE Trans. Biomed. Circuits Syst. 12, 390–401 (2018).10.1109/TBCAS.2017.2789161 ↗
15. Douthwaite, M., Koutsos, E., Yates, D. C., Mitcheson, P. D. & Georgiou, P. A thermally powered ISFET array for on-body pH measurement. IEEE Trans. Biomed. Circuits Syst. 11, 1324–1334 (2017).10.1109/TBCAS.2017.2727219 ↗
16. Rajan, N. K., Brower, K., Duan, X. & Reed, M. A. Limit of detection of field effect transistor biosensors: effects of surface modification and size dependence. Appl. Phys. Lett. 104, 084106 (2014).10.1063/1.4867025 ↗
17. Kilic, T., Erdem, A., Ozsoz, M. & Carrara, S. microRNA biosensors: Opportunities and challenges among conventional and commercially available techniques. Biosens. Bioelectron. 99, 525–546 (2018).10.1016/j.bios.2017.08.007 ↗
18. Kaisti, M. et al. Real-time wash-free detection of unlabeled PNA-DNA hybridization using discrete fet sensor. Sci. Rep. 7, 15734 (2017).10.1038/s41598-017-16028-7 ↗
19. Thompson, M. et al. Label-free detection of nucleic acid and protein microarrays by scanning Kelvin nanoprobe. Biosens. Bioelectron. 20, 1471–1481 (2005).10.1016/j.bios.2004.06.022 ↗
20. Liao, W. et al. pH sensing and low-frequency noise characteristics of low temperature (400 °C) p-channel SOI schottky ISFETs. IEEE Electron Device Lett. 38, 1146–1149 (2017).10.1109/LED.2017.2716959 ↗
21. Ishige, Y., Shimoda, M. & Kamahori, M. Immobilization of DNA probes onto gold surface and its application to fully electric detection of DNA hybridization using field-effect transistor sensor. Jpn. J. Appl. Phys. 45, 3776–3783 (2006).10.1143/JJAP.45.3776 ↗
22. Xu, S. et al. Real-time reliable determination of binding kinetics of DNA hybridization using a multi-channel graphene biosensor. Nat. Commun. 8, 14902 (2017).10.1038/ncomms14902 ↗
23. Huang, Y. et al. Scalable processing of low voltage organic field effect transistors with a facile soft-contact coating approach. IEEE Electron Device Lett. 40, 1945–1948 (2019).10.1109/LED.2019.2950345 ↗
24. Tang, W., Feng, L., Yu, P., Zhao, J. & Guo, X. Highly efficient all-solution-processed low-voltage organic transistor with a micrometer-thick low-k polymer gate dielectric layer. Adv. Electron. Mater. 2, 1500454 (2016).10.1002/aelm.201500454 ↗
25. Lee, W. H., Choi, H. H., Kim, D. H. & Cho, K. 25th anniversary article: microstructure dependent bias stability of organic transistors. Adv. Mater. 26, 1660–1680 (2014).10.1002/adma.201304665 ↗
26. Mittal, S., Kaur, H., Gautam, N. & Mantha, A. K. Biosensors for breast cancer diagnosis: a review of bioreceptors, biotransducers and signal amplification strategies. Biosens. Bioelectron. 88, 217–231 (2017).10.1016/j.bios.2016.08.028 ↗
27. Qian, S. et al. Boronic acid functionalized Au nanoparticles for selective microRNA signal amplification in fiber-optic surface plasmon resonance sensing system. ACS Sens 3, 929–935 (2018).10.1021/acssensors.7b00871 ↗
28. Yang, C.-T., Pourhassan-Moghaddam, M., Wu, L., Bai, P. & Thierry, B. Ultrasensitive detection of cancer prognostic miRNA biomarkers based on surface plasmon enhanced light scattering. ACS Sens. 2, 635–640 (2017).10.1021/acssensors.6b00776 ↗
29. Dorvel, B. R. et al. Silicon nanowires with high-k hafnium oxide dielectrics for sensitive detection of small nucleic acid oligomers. ACS Nano 6, 6150–6164 (2012).10.1021/nn301495k ↗
30. Lu, N. et al. CMOS-compatible silicon nanowire field-effect transistors for ultrasensitive and label-free microRNAs sensing. Small 10, 2022–2028 (2014).10.1002/smll.201302990 ↗
31. Ganguli, A., Watanabe, Y., Hwang, M. T., Huang, J.-C. & Bashir, R. Robust label-free microRNA detection using one million ISFET array. Biomed. Microdevices 20, 45 (2018).10.1007/s10544-018-0290-8 ↗
32. Li, J., Sun, Z. & Yan, F. Solution processable low-voltage organic thin film transistors with high-k relaxor ferroelectric polymer as gate insulator. Adv. Mater. 24, 88–93 (2012).10.1002/adma.201103542 ↗