journal article·2023-02-11Open access

Origami-inspired perovskite X-ray detector by printing and folding

Henning Mescher, Fabian Schackmar, Robert Huber, Helge Eggers, Marcus Zuber, Elias Hamann, Georg Gramlich, Julian Dangelmaier, Qiaoshuang Zhang, Andres Georg Rösch, Thomas Zwick, Gerardo Hernandez-Sosa, Ulrich W. Paetzold, Uli Lemmer

npj Flexible Electronics· Volume 7· Issue 1

Abstract

Abstract X-ray detectors are of pivotal importance for the scientific and technological progress in a wide range of medical, industrial, and scientific applications. Here, we take advantage of the printability of perovskite-based semiconductors and achieve a high X-ray sensitivity combined with the potential of an exceptional high spatial resolution by our origami-inspired folded perovskite X-ray detector. The high performance of our device is reached solely by the folded detector architecture and does not require any photolithography. The design and fabrication of a foldable perovskite sensor array is presented and the detector is characterized as a planar and as a folded device. Exposed to 50 kVp−150 kVp X-ray radiation, the planar detector reaches X-ray sensitivities of 25−35 μC/(Gyaircm2), whereas the folded detector achieves remarkably increased X-ray sensitivities of several hundred μC/(Gyaircm2) and a record value of 1409 μC/(Gyaircm2) at 150 kVp without photoconductive gain. Finally, the potential of an exceptional high spatial resolution of the folded detector of more than 20 lp/mm under 150 kVp X-ray radiation is demonstrated.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Perovskite Materials and Applications · Ga2O3 and related materials · Gas Sensing Nanomaterials and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Kalender, W. A. X-ray computed tomography. Phys. Med. Biol. 51, R29–R43 (2006).10.1088/0031-9155/51/13/R03 ↗
2. Spahn, M. X-ray detectors in medical imaging. Nucl. Instrum. Methods Phys. Res. A: Accelerators Spectrometers Detectors Assoc. Equipment 731, 57–63 (2013).10.1016/j.nima.2013.05.174 ↗
3. Kotwaliwale, N. et al. X-ray imaging methods for internal quality evaluation of agricultural produce. J. Food Sci. Technol. 51, 1–15 (2014).10.1007/s13197-011-0485-y ↗
4. De Chiffre, L., Carmignato, S., Kruth, J.-P., Schmitt, R. & Weckenmann, A. Industrial applications of computed tomography. CIRP Annals 63, 655–677 (2014).10.1016/j.cirp.2014.05.011 ↗
5. Bunaciu, A. A., gabriela Udriştioiu, E. & Aboul-Enein, H. Y. X-ray diffraction: instrumentation and applications. Crit. Rev. Anal. Chem. 45, 289–299 (2015).10.1080/10408347.2014.949616 ↗
6. van de Kamp, T. et al. Evolution of flexible biting in hyperdiverse parasitoid wasps. Proc. R. Soc. B: Biol. Sci. 289, 1–9 (2022).10.1098/rspb.2021.2086 ↗
7. He, Y., Hadar, I. & Kanatzidis, M. G. Detecting ionizing radiation using halide perovskite semiconductors processed through solution and alternative methods. Nat. Photonics 16, 14–26 (2022).10.1038/s41566-021-00909-5 ↗
8. Basiricò, L., Ciavatti, A. & Fraboni, B. Solution-grown organic and perovskite x-ray detectors: a new paradigm for the direct detection of ionizing radiation. Adv. Mater. Technol. 6, 2000475 (2020).10.1002/admt.202000475 ↗
9. Zhou, Y., Chen, J., Bakr, O. M. & Mohammed, O. F. Metal halide perovskites for X-ray imaging scintillators and detectors. ACS Energy Lett. 6, 739–768 (2021).10.1021/acsenergylett.0c02430 ↗
10. Kakavelakis, G. et al. Metal halide perovskites for high-energy radiation detection. Adv. Sci. 7, 2002098 (2020).10.1002/advs.202002098 ↗
11. Wei, H. & Huang, J. Halide lead perovskites for ionizing radiation detection. Nat. Commun. 10, 1066 (2019).10.1038/s41467-019-08981-w ↗
12. Li, C. et al. Ultrafast and broadband photodetectors based on a perovskite/organic bulk heterojunction for large-dynamic-range imaging. Light: Sci. Appl. 9, 31 (2020).10.1038/s41377-020-0264-5 ↗
13. Morteza Najarian, A. et al. Sub-millimetre light detection and ranging using perovskites. Nat. Electron. 5, 511–518 (2022).10.1038/s41928-022-00799-7 ↗
14. Yao, M. et al. High-temperature stable FAPbBr3 single crystals for sensitive X-ray and visible light detection toward space. Nano Lett. 21, 3947–3955 (2021).10.1021/acs.nanolett.1c00700 ↗
15. Gu, Y. et al. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET. Phys. Med. Biol. 56, 1563–1584 (2011).10.1088/0031-9155/56/6/004 ↗
16. Liu, X., Grönberg, F., Sjölin, M., Karlsson, S. & Danielsson, M. Count rate performance of a silicon-strip detector for photon-counting spectral CT. Nucl. Instrum. Methods Phys. Res. A: Accelerators Spectrometers Detectors Associated Equipment 827, 102–106 (2016).10.1016/j.nima.2016.04.087 ↗
17. Mescher, H., Hamann, E. & Lemmer, U. Simulation and design of folded perovskite x-ray detectors. Sci. Rep. 9, 5231 (2019).10.1038/s41598-019-41440-6 ↗
18. Mescher, H. et al. Flexible inkjet-printed triple cation perovskite X-ray detectors. ACS Appl. Mater. Interfaces 12, 15774–15784 (2020).10.1021/acsami.9b14649 ↗
19. Kasap, S. O. X-ray sensitivity of photoconductors: application to stabilized a-Se. J. Phys. D: Appl. Phys. 33, 2853–2865 (2000).10.1088/0022-3727/33/21/326 ↗
20. Pan, Z., Wu, L., Jiang, J., Shen, L. & Yao, K. Searching for high-quality halide perovskite single crystals toward X-ray detection. J. Phys. Chem. Lett. 13, 2851–2861 (2022).10.1021/acs.jpclett.2c00450 ↗
21. Boreman, G. D. MTF Measurement methods. In: Modulation Transfer Function in Optical and Electro-Optical Systems, Chapter 4, 69–84 (SPIE, 2001). http://ebooks.spiedigitallibrary.org/content.aspx?doi=10.1117/3.419857.ch4.
22. Cunningham, I. Applied linear-systems theory. In: Handbook of Medical Imaging, Volume 1. Physics and Psychophysics, 79–159 (SPIE, 2000). http://ebooks.spiedigitallibrary.org/content.aspx?doi=10.1117/3.832716.ch2.10.1117/3.832716.ch2 ↗
23. Heilmaier, C., Zuber, N. & Weishaupt, D. Implementation of a patient dose monitoring system in conventional digital X-ray imaging: initial experiences. Eur. Radiol. 27, 1021–1031 (2017).10.1007/s00330-016-4390-7 ↗
24. Schackmar, F. et al. Perovskite solar cells with all-inkjet-printed absorber and charge transport layers. Adv. Mater. Technol. 6, 2000271 (2021).10.1002/admt.202000271 ↗
25. Eggers, H. et al. Inkjet-printed micrometer-thick perovskite solar cells with large columnar grains. Adv. Energy Mater. 10, 1903184 (2020).10.1002/aenm.201903184 ↗
26. Punnoose, J., Xu, J., Sisniega, A., Zbijewski, W. & Siewerdsen, J. H. Technical Note: spektr 3.0-A computational tool for x-ray spectrum modeling and analysis. Med. Phys. 43, 4711–4717 (2016).10.1118/1.4955438 ↗
27. Devanathan, R., Corrales, L. R., Gao, F. & Weber, W. J. Signal variance in gamma-ray detectors—a review. Nucl. Instrum. Methods Phys. Res. A: Accelerators Spectrometers Detectors Associated Equipment 565, 637–649 (2006).10.1016/j.nima.2006.05.085 ↗
28. Klein, C. A. Bandgap dependence and related features of radiation ionization energies in semiconductors. J. Appl. Phys. 39, 2029–2038 (1968).10.1063/1.1656484 ↗
29. Que, W. & Rowlands, J. A. X-ray photogeneration in amorphous selenium: geminate versus columnar recombination. Phys. Rev. B 51, 10500–10507 (1995).10.1103/PhysRevB.51.10500 ↗
30. Tosado, G. A., Lin, Y. Y., Zheng, E. & Yu, Q. Impact of cesium on the phase and device stability of triple cation Pb-Sn double halide perovskite films and solar cells. J. Mater. Chem. A 6, 17426–17436 (2018).10.1039/C8TA06391E ↗
31. Boone, J. M. & Seibert, J. A. An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF. Med. Phys. 21, 1541–1545 (1994).10.1118/1.597264 ↗
32. Wei, W. et al. Monolithic integration of hybrid perovskite single crystals with heterogenous substrate for highly sensitive X-ray imaging. Nat. Photonics 11, 315–321 (2017).10.1038/nphoton.2017.43 ↗
33. Jiang, J. et al. Synergistic strain engineering of perovskite single crystals for highly stable and sensitive X-ray detectors with low-bias imaging and monitoring. Nat. Photonics 16, 575–581 (2022).10.1038/s41566-022-01024-9 ↗
34. Kim, Y. C. et al. Printable organometallic perovskite enables large-area, low-dose X-ray imaging. Nature 550, 87–91 (2017).10.1038/nature24032 ↗
35. Yang, B. et al. Heteroepitaxial passivation of Cs2AgBiBr6 wafers with suppressed ionic migration for X-ray imaging. Nat. Commun. 10, 1989 (2019).10.1038/s41467-019-09968-3 ↗
36. Liu, Y. et al. Large lead-free perovskite single crystal for high-performance coplanar X-ray imaging applications. Adv. Opt. Mater. 8, 2000814 (2020).10.1002/adom.202000814 ↗
37. Deumel, S. et al. High-sensitivity high-resolution X-ray imaging with soft-sintered metal halide perovskites. Nat. Electron. 4, 681–688 (2021).10.1038/s41928-021-00644-3 ↗
38. Song, Y. et al. Elimination of interfacial-electrochemical-reaction-induced polarization in perovskite single crystals for ultrasensitive and stable X-ray detector arrays. Adv. Mater. 33, 2103078 (2021).10.1002/adma.202103078 ↗