journal article·2025-12-26Open access

WoundMx: multiplexed detection of wound infection biomarkers with a multimodal sensor system based on laser-induced graphene

Heshmat Asgharian, Vinay Kammarchedu, Scott J. Gu, Aida Ebrahimi

npj 2D Materials and Applications· Volume 10· Issue 1

Abstract

Multiplexed monitoring of wound biomarkers is essential for early detection of infection, inflammation, and assessment of healing. However, existing biosensors lack the sensitivity, specificity, and integration required for clinical needs. We developed a portable multimodal sensing chip to simultaneously detect multiple wound-relevant biomarkers. Specifically, the device integrates laser-induced graphene (LIG) electrodes for differential pulse voltammetry-based detection of uric acid and phenazine-1-carboxylic acid (a biomarker of Pseudomonas aeruginosa ), open-circuit potential reading of pH using polyaniline-modified LIG, and a LIG-based extended-gate field effect transistor for detecting interleukin-6. We validated the devices in phosphate-buffered saline and wound simulating medium and demonstrated accurate, multiplexed detection in clinical ranges. Furthermore, in vitro experiments with an agar-based wound model highlighted the system’s promise for wound monitoring. The sensing chip was integrated with a wireless analyzer for real-time data acquisition. This minimally invasive platform could support continuous wound assessment by monitoring infection and inflammation for future smart wound dressings.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wound Healing and Treatments · Planarian Biology and Electrostimulation · Advanced Sensor and Energy Harvesting Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (91)

Show source-provided references
1. Sen, C. K. et al. Human skin wounds: a major and snowballing threat to public health and the economy. Wound Repair Regen. 17, 763–771 (2009).10.1111/j.1524-475X.2009.00543.x ↗
2. National Burn Awareness Week and Workers’ Compensation | Paradigm. https://www.paradigmcorp.com/insights/burn-awareness-week-2022-paradigm/.
3. Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L. & Fowler, V. G. Staphylococcus aureus infections: epidemiology, pathophysiology, clinical manifestations, and management. Clin. Microbiol. Rev. 28, 603–661 (2015).10.1128/CMR.00134-14 ↗
4. Reynolds, D. & Kollef, M. The epidemiology and pathogenesis and treatment of pseudomonas aeruginosa infections: an update. Drugs 81, 2117–2131 (2021).10.1007/s40265-021-01635-6 ↗
5. Bertesteanu, S. et al. Polymicrobial wound infections: pathophysiology and current therapeutic approaches. Int. J. Pharm. 463, 119–126 (2014).10.1016/j.ijpharm.2013.12.012 ↗
6. Ladhani, H. A., Yowler, C. J. & Claridge, J. A. Burn wound colonization, infection, and sepsis. Surg. Infect. 22, 44–48 (2021).10.1089/sur.2020.346 ↗
7. Manoharan Nair Sudha Kumari, S. & Thankappan Suryabai, X. Sensing the future─frontiers in biosensors: exploring classifications, principles, and recent advances. ACS Omega 9, 48918–48987 (2024).10.1021/acsomega.4c07991 ↗
8. Teixeira, W. et al. An all-in-one point-of-care testing device for multiplexed detection of respiratory infections. Biosens. Bioelectron. 213, 1–7 (2022).10.1016/j.bios.2022.114454 ↗
9. Wang, C. et al. Point-of-care diagnostics for infectious diseases: from methods to devices. Nano Today 37, 101092 (2021).10.1016/j.nantod.2021.101092 ↗
10. Moeinfard, T., Ghafar-Zadeh, E. & Magierowski, S. CMOS point-of-care diagnostics technologies: recent advances and future prospects. Micromachines 15, 1–28 (2024).10.3390/mi15111320 ↗
11. Arcangeli, D. et al. Smart bandaid integrated with fully textile OECT for uric acid real-time monitoring in wound exudate. ACS Sens. 8, 1593–1608 (2023).10.1021/acssensors.2c02728 ↗
12. Annemans, L. et al. Gout in the UK and Germany: prevalence, comorbidities and management in general practice 2000-2005. Ann. Rheum. Dis. 67, 960–966 (2008).10.1136/ard.2007.076232 ↗
13. VanDrisse, C. M., Lipsh-Sokolik, R., Khersonsky, O., Fleishman, S. J. & Newman, D. K. Computationally designed pyocyanin demethylase acts synergistically with tobramycin to kill recalcitrant Pseudomonas aeruginosa biofilms. Proc. Natl. Acad. Sci. USA 118, e2022012118 (2021).10.1073/pnas.2022012118 ↗
14. Costerton, J. W., Stewart, P. S. & Greenberg, E. P. Bacterial biofilms: a common cause of persistent infections. Science (1979) 284, 1318–1322 (1999).
15. Zhou, K., Kammarchedu, V., Butler, D., Soltan Khamsi, P. & Ebrahimi, A. Electrochemical sensors based on MoSx-functionalized laser-induced graphene for real-time monitoring of phenazines produced by pseudomonas aeruginosa. Adv. Health Mater. 11, 2200773 (2022).10.1002/adhm.202200773 ↗
16. Parsons, J. F. et al. Structural and functional analysis of the pyocyanin biosynthetic protein PhzM from Pseudomonas aeruginosa. Biochemistry 46, 1821–1828 (2007).10.1021/bi6024403 ↗
17. Muller, M., Li, Z. & Maitz, P. K. M. Pseudomonas pyocyanin inhibits wound repair by inducing premature cellular senescence: role for p38 mitogen-activated protein kinase. Burns 35, 500–508 (2009).10.1016/j.burns.2008.11.010 ↗
18. Truong-Bolduc, Q. C. et al. Phenazine-1 carboxylic acid of Pseudomonas aeruginosa induces the expression of Staphylococcus aureus Tet38 MDR efflux pump and mediates resistance to phenazines and antibiotics. Antimicrob. Agents Chemother. 68, e0063624 (2024).10.1128/aac.00636-24 ↗
19. Chukwubuikem, A., Berger, C., Mady, A. & Rosenbaum, M. A. Role of phenazine-enzyme physiology for current generation in a bioelectrochemical system. Microb. Biotechnol. 14, 1613–1626 (2021).10.1111/1751-7915.13827 ↗
20. Mahmoud, N. N. et al. Investigating Inflammatory Markers in Wound Healing: Understanding Implications and Identifying Artifacts. ACS Pharm. Transl. Sci. 7, 18–27 (2024).10.1021/acsptsci.3c00336 ↗
21. Huang, L. et al. Sepsis-associated severe interleukin-6 storm in critical coronavirus disease 2019. Cell Mol. Immunol. 17, 1092–1094 (2020).10.1038/s41423-020-00522-6 ↗
22. Rudd, K. E. et al. Global, regional, and national sepsis incidence and mortality, 1990–2017: analysis for the Global Burden of Disease Study. Lancet 395, 200–211 (2020).10.1016/S0140-6736(19)32989-7 ↗
23. Kobayashi, T., Iwatani, S., Hirata, A., Yamamoto, M. & Yoshimoto, S. Rapid changes in serum IL-6 levels in preterm newborns with Gram-negative early-onset sepsis. Cytokine 138, 155371 (2021).10.1016/j.cyto.2020.155371 ↗
24. Battaglia, T. M. et al. Quantification of cytokines involved in wound healing using surface plasmon resonance. Anal. Chem. https://doi.org/10.1021/ac050568w (2005).10.1021/ac050568w ↗
25. Reinhart, K., Meisner, M. & Brunkhorst, F. M. Markers for sepsis diagnosis: What is useful?. Crit. Care Clin. 22, 503–519 (2006).10.1016/j.ccc.2006.03.003 ↗
26. Bloos, F. & Reinhart, K. Rapid diagnosis of sepsis. Virulence 5, 154–160 (2014).10.4161/viru.27393 ↗
27. Bennison, L. et al. The pH of wounds during healing and infection: a descriptive literature review. Wound Pract. Res. J. Aust. Wound Manag. Assoc. 25, 63–69 (2017).
28. Blicharz, T. M. et al. Use of colorimetric test strips for monitoring the effect of hemodialysis on salivary nitrite and uric acid in patients with end-stage renal disease: a proof of principle. Clin. Chem. 54, 1473–1480 (2008).10.1373/clinchem.2008.105320 ↗
29. Pal, J. & Pal, T. Enzyme mimicking inorganic hybrid Ni@MnO2 for colorimetric detection of uric acid in serum samples. RSC Adv. 6, 83738–83747 (2016).10.1039/C6RA11483K ↗
30. Zhou, S. et al. An eco-friendly hydrophilic interaction HPLC method for the determination of renal function biomarkers, creatinine and uric acid, in human fluids. Anal. Methods 5, 1307–1311 (2013).10.1039/c2ay26362a ↗
31. Jen, J.-F., Hsiao, S.-L. & Liu, K.-H. Simultaneous determination of uric acid and creatinine in urine by an eco-friendly solvent-free high performance liquid chromatographic method. Talanta 58, 711–717 (2002).10.1016/S0039-9140(02)00377-6 ↗
32. Zhao, J. A simple, rapid and reliable high performance liquid chromatography method for the simultaneous determination of creatinine and uric acid in plasma and urine. Anal. Methods 5, 6781–6787 (2013).10.1039/c3ay41061g ↗
33. Villageliú, D. & Lyte, M. Dopamine production in Enterococcus faecium: a microbial endocrinology-based mechanism for the selection of probiotics based on neurochemical-producing potential. PLoS ONE 13, 1–10 (2018).10.1371/journal.pone.0207038 ↗
34. Costa, K. C., Moskatel, L. S., Meirelles, L. A. & Newman, D. K. PhdA catalyzes the first step of phenazine-1-carboxylic acid degradation in Mycobacterium fortuitum. J. Bacteriol. 200, 1–10 (2018).10.1128/JB.00763-17 ↗
35. DeBritto, S. et al. Isolation and characterization of nutrient dependent pyocyanin from Pseudomonas aeruginosa and its dye and agrochemical properties. Sci. Rep. 10, 1–12 (2020).10.1038/s41598-020-58335-6 ↗
36. Dwivedi, S., AlKhedhairy, A. A., Ahamed, M. & Musarrat, J. Biomimetic synthesis of selenium nanospheres by bacterial strain JS-11 and its role as a biosensor for nanotoxicity assessment: a novel se-bioassay. PLoS ONE 8, 1–10 (2013).10.1371/journal.pone.0057404 ↗
37. Iloabuchi, K. & Spiteller, D. Bacillus sp. G2112 detoxifies phenazine-1-carboxylic acid by N5 glucosylation. Molecules 29, 1–18 (2024).10.3390/molecules29030589 ↗
38. El-Fouly, M. Z., Sharaf, A. M., Shahin, A. A. M., El-Bialy, H. A. & Omara, A. M. A. Biosynthesis of pyocyanin pigment by Pseudomonas aeruginosa. J. Radiat. Res. Appl. Sci. 8, 36–48 (2015).
39. Heydorn, A. et al. Experimental reproducibility in flow-chamber biofilms. Microbiology 146, 2409–2415 (2000).10.1099/00221287-146-10-2409 ↗
40. Helle, M., Boeije, L., de Groot, E., de Vos, A. & Aarden, L. Sensitive ELISA for interleukin-6. Detection of IL-6 in biological fluids: synovial fluids and sera. J. Immunol. Methods 138, 47–56 (1991).10.1016/0022-1759(91)90063-L ↗
41. Luo, L., Zhang, Z., Hou, L., Wang, J. & Tian, W. The study of a chemiluminescence immunoassay using the peroxyoxalate chemiluminescent reaction and its application. Talanta 72, 1293–1297 (2007).10.1016/j.talanta.2007.01.030 ↗
42. Ghoneim, M. T. et al. Recent progress in electrochemical pH-sensing materials and configurations for biomedical applications. Chem. Rev. 119, 5248–5297 (2019).10.1021/acs.chemrev.8b00655 ↗
43. Wang, C. et al. Wound management materials and technologies from bench to bedside and beyond. Nat. Rev. Mater. 9, 550–566 (2024).10.1038/s41578-024-00693-y ↗
44. Huang, S. W., Wu, Y. F., Ahmed, T., Pan, S. C. & Cheng, C. M. Point-of-care detection devices for wound care and monitoring. Trends Biotechnol. 42, 74–90 (2024).10.1016/j.tibtech.2023.07.001 ↗
45. Youssef, K., Ullah, A., Rezai, P., Hasan, A. & Amirfazli, A. Recent advances in biosensors for real time monitoring of pH, temperature, and oxygen in chronic wounds. Mater. Today Bio 22, 100764 (2023).10.1016/j.mtbio.2023.100764 ↗
46. Pang, Q. et al. Smart wound dressing for advanced wound management: Real-time monitoring and on-demand treatment. Mater. Des. 229, 111917 (2023).10.1016/j.matdes.2023.111917 ↗
47. Vo, D.-K. & Trinh, K. T. L. Advances in wearable biosensors for wound healing and infection monitoring. Biosensors 15, 139 (2025).10.3390/bios15030139 ↗
48. Gupta, E. et al. Fast track diagnostic tools for clinical management of sepsis: paradigm shift from conventional to advanced methods. Diagnostics 13, 1–23 (2023).10.3390/diagnostics13020277 ↗
49. Li, S., Renick, P., Senkowsky, J., Nair, A. & Tang, L. Diagnostics for wound infections. Adv. Wound Care 10, 317–327 (2021).10.1089/wound.2019.1103 ↗
50. Galliani, M. et al. Flexible printed organic electrochemical transistors for the detection of uric acid in artificial wound exudate. Adv. Mater. Interfaces 7, 1–7 (2020).10.1002/admi.202001218 ↗
51. Kaewpradub, K., Veenuttranon, K., Jantapaso, H., Mittraparp-arthorn, P. & Jeerapan, I. A Fully-printed wearable bandage-based electrochemical sensor with ph correction for wound infection monitoring. Nanomicro. Lett. 17, 1–21 (2025).
52. Dou, C. et al. Au-functionalized wrinkle graphene biosensor for ultrasensitive detection of Interleukin-6. Carbon 216, 118556 (2024).10.1016/j.carbon.2023.118556 ↗
53. Kumar, M. A., Jayavel, R., Mahalingam, S., Kim, J. & Atchudan, R. Detection of interleukin-6 protein using graphene field-effect transistor. Biosensors 13, 834 (2023).10.3390/bios13090834 ↗
54. Hwang, M. T. et al. Ultrasensitive detection of dopamine, IL-6 and SARS-CoV-2 proteins on crumpled graphene FET biosensor. Adv. Mater. Technol. 6, 2100712 (2021).10.1002/admt.202100712 ↗
55. Meng, L., Liu, S., Borsa, B., Eriksson, M. & Mak, W. C. A conducting polymer-based array with multiplex sensing and drug delivery capabilities for smart bandages. Commun. Mater. https://doi.org/10.1038/s43246-024-00469-5 (2024).10.1038/s43246-024-00469-5 ↗
56. Sani, E. S. et al. A stretchable wireless wearable bioelectronic system for multiplexed monitoring and combination treatment of infected chronic wounds. Sci. Adv. 9, 1–16 (2023).
57. Movaghgharnezhad, S. & Kang, P. Laser-induced graphene: synthesis advances, structural tailoring, enhanced properties, and sensing applications. J. Mater. Chem. C Mater. 12, 6718–6742 (2024).10.1039/D3TC04677J ↗
58. Aftab, S. et al. Laser-induced graphene for advanced sensing: comprehensive review of applications. ACS Sens. https://doi.org/10.1021/acssensors.4c01717 (2024).10.1021/acssensors.4c01717 ↗
59. Dixit, N. & Singh, S. P. Laser-induced graphene (LIG) as a smart and sustainable material to restrain pandemics and endemics: a perspective. ACS Omega 7, 5112–5130 (2022).10.1021/acsomega.1c06093 ↗
60. Cheng, L. et al. Flash healing of laser-induced graphene. Nat. Commun. 15, 1–11 (2024).
61. Shokurov, A. V. & Menon, C. Laser-induced graphene electrodes for electrochemistry education and research. J. Chem. Educ. 100, 2411–2417 (2023).10.1021/acs.jchemed.2c01237 ↗
62. Le, T. S. D. et al. Recent advances in laser-induced graphene: mechanism, fabrication, properties, and applications in flexible electronics. Adv. Funct. Mater. 32, 1–39 (2022).
63. Zhang, Z. et al. A review of laser-induced graphene: from experimental and theoretical fabrication processes to emerging applications. Carbon 214, 118356 (2023).10.1016/j.carbon.2023.118356 ↗
64. Lin, J. et al. Laser-induced porous graphene films from commercial polymers. Nat. Commun. 5, 5–12 (2014).10.1038/ncomms6714 ↗
65. Kammarchedu, V., Asgharian, H., Zhou, K., Soltan Khamsi, P. & Ebrahimi, A. Recent advances in graphene-based electroanalytical devices for healthcare applications. Nanoscale 16, 12857–12882 (2024).10.1039/D3NR06137J ↗
66. Brustoloni, C. J. M., Soltan Khamsi, P., Kammarchedu, V. & Ebrahimi, A. Systematic study of various functionalization steps for ultrasensitive detection of SARS-CoV-2 with direct laser-functionalized Au-LIG electrochemical sensors. ACS Appl. Mater. Interfaces https://doi.org/10.1021/acsami.4c09571 (2024).10.1021/acsami.4c09571 ↗
67. Albarghouthi, F. M. et al. Addressing signal drift and screening for detection of biomarkers with carbon nanotube transistors. ACS Nano https://doi.org/10.1021/acsnano.3c11679 (2023).10.1021/acsnano.3c11679 ↗
68. Garland, N. T. et al. Wearable flexible perspiration biosensors using laser-induced graphene and polymeric tape microfluidics. ACS Appl. Mater. Interfaces 15, 38201–38213 (2023).10.1021/acsami.3c04665 ↗
69. Camargo, J. R. et al. Development of new simple compositions of silver inks for the preparation of pseudo-reference electrodes. Biosensors 12, 761 (2022).10.3390/bios12090761 ↗
70. Zdrachek, E. & Bakker, E. Potentiometric sensor array with multi-nernstian slope. Anal. Chem. 92, 2926–2930 (2020).10.1021/acs.analchem.9b05187 ↗
71. U.S. Food and Drug Administration. M10 Bioanalytical Method Validation and Study Sample Analysis. FDA. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/m10-bioanalytical-method-validation-and-study-sample-analysis (2022).
72. Huang, J., Fan, C., Ma, Y. & Huang, G. Exploring thermal dynamics in wound healing: the impact of temperature and microenvironment. Clin. Cosmet. Investig. Dermatol. 17, 1251–1258 (2024).10.2147/CCID.S468396 ↗
73. Asgharian, H., Kammarchedu, V., Soltan Khamsi, P., Brustoloni, C. & Ebrahimi, A. Multi-electrode extended gate field effect transistors based on laser-induced graphene for the detection of vitamin C and SARS-CoV-2. ACS Appl. Mater. Interfaces 16, 63142–63154 (2024).10.1021/acsami.4c11393 ↗
74. Sheibani, S. et al. Extended gate field-effect-transistor for sensing cortisol stress hormone. Commun. Mater. 2, 1–10 (2021).10.1038/s43246-020-00114-x ↗
75. Asgharian, H., Khodayari, M., Rajabali, M. & Mohajerzadeh, S. Molecule-induced n-type behavior of phosphorene-based field-effect transistor for highly sensitive detection of sialic acid. Electrochim. Acta 469, 143228 (2023).10.1016/j.electacta.2023.143228 ↗
76. Rajabali, M. et al. Experimental and molecular dynamics studies of an ultra-fast sequential hydrogen plasma process for fabricating phosphorene-based sensors. Sci. Rep. 11, 1–13 (2021).10.1038/s41598-021-95463-z ↗
77. Könemund, L. et al. Functionalization of an extended-gate field-effect transistor (EGFET) for bacteria detection. Sci. Rep. 12, 1–10 (2022).10.1038/s41598-022-08272-3 ↗
78. Kuo, P. Y., Chang, C. H., Lai, W. H. & Wang, T. H. The characteristics analysis of a microfluid-based EGFET biosensor with on-chip sensing film for lactic acid detection. Sensors 22, 5905 (2022).10.3390/s22155905 ↗
79. Sharma, P. et al. Palladium-oxide extended gate field effect transistor as pH sensor. Mater. Lett. X 12, 100102 (2021).
80. Talley, K. & Alexov, E. On the pH-optimum of activity and stability of proteins. Proteins: Struct. Funct. Bioinform. 78, 2699–2706 (2010).10.1002/prot.22786 ↗
81. Ma, H., Ó’Fágáin, C. & O’Kennedy, R. Antibody stability: a key to performance—analysis, influences and improvement. Biochimie 177, 213–225 (2020).10.1016/j.biochi.2020.08.019 ↗
82. Crone, S., Garde, C., Bjarnsholt, T. & Alhede, M. A novel in vitro wound biofilm model used to evaluate low-frequency ultrasonic-assisted wound debridement. J. Wound Care 24, 64–72 (2015).10.12968/jowc.2015.24.2.64 ↗
83. Dang, W. et al. Stretchable wireless system for sweat pH monitoring. Biosens. Bioelectron. 107, 192–202 (2018).10.1016/j.bios.2018.02.025 ↗
84. Dallinger, A., Steinwender, F., Gritzner, M. & Greco, F. Different roles of surface chemistry and roughness of laser-induced graphene: implications for tunable wettability. ACS Appl. Nano Mater. 6, 16201–16211 (2023).10.1021/acsanm.3c02066 ↗
85. Wirojsaengthong, S., Chailapakul, O., Tangkijvanich, P., Henry, C. S. & Puthongkham, P. Size-dependent electrochemistry of laser-induced graphene electrodes. Electrochim. Acta 494, 144452 (2024).10.1016/j.electacta.2024.144452 ↗
86. Nazeri, M., Ghalamboran, M. & Grau, G. Laser-induced graphene electrodes for organic electrochemical transistors (OECTs). Adv. Mater. Technol. 8, 1–13 (2023).10.1002/admt.202300188 ↗
87. Liu, Z. et al. Dynamic laser speckle imaging meets machine learning to enable rapid antibacterial susceptibility testing (DYRAST). ACS Sens. 5, 3140–3149 (2020).10.1021/acssensors.0c01238 ↗
88. Behrent, A., Griesche, C., Sippel, P. & Baeumner, A. J. Process-property correlations in laser-induced graphene electrodes for electrochemical sensing. Microchim. Acta 188, 159 (2021).10.1007/s00604-021-04792-3 ↗
89. Kammarchedu, V., AlSiyabi, M. & Ebrahimi, A. Skin-conformal myography for real-time hand tracking using a laser-induced graphene strain sensor array. Adv. Intelli. Syst 7, 2400812 (2025).10.1002/aisy.202400812 ↗
90. Alnoush, W., Black, R. & Higgins, D. Judicious selection, validation, and use of reference electrodes for in situ and operando electrocatalysis studies. Chem. Catal. 1, 997–1013 (2021).
91. Maheshwari, P. H. Developing the processing stages of carbon fiber composite paper as efficient materials for energy conversion, storage, and conservation. Mater. Sci. Energy Technol. 2, 490–502 (2019).