Wearable Perovskite Films for On‐Line Monitoring of Radiotracers in Nuclear Medicine
Source abstract
Abstract
Abstract On‐line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA 2 PbBr 4 are tested for the monitoring of gamma‐rays emitted by 18 F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real‐time the gamma‐rays emitted by annihilation of 18 F radiotracer. Its reliability is assessed by 18 F half‐life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real‐time the whole injection process and extravasation event.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Perovskite Materials and Applications · 2D Materials and Applications · Machine Learning in Materials Science
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics and Astronomy University of Bologna Viale Berti Pichat 6/2 Bologna 40127 Italy
National Institute for Nuclear Physics—INFN section of Bologna Viale Berti‐Pichat 6/2 Bologna 40127 Italy
Medical Physics Unit Azienda USL‐IRCCS di Reggio Emilia Reggio Emilia 42123 Italy
Funding
Regione Emilia-Romagna · Ministero della Salute
References (29)
Show source-provided references
1. SAMIRA Action Plan ‐ European Commission.https://energy.ec.europa.eu/topics/nuclear‐energy/radiological‐and‐nuclear‐technology‐health/samira‐action‐plan.
2. 10.1016/j.radi.2020.07.01310.1016/j.radi.2020.07.013 ↗
3. 10.1111/j.1749-6632.2011.06077.x10.1111/j.1749-6632.2011.06077.x ↗
4. 10.1093/oxfordjournals.rpd.a00670510.1093/oxfordjournals.rpd.a006705 ↗
5. Cherry S. R. · 2006 · 1
6. 10.1186/s40658-023-00556-510.1186/s40658-023-00556-5 ↗
7. 10.3390/cancers1605103210.3390/cancers16051032 ↗
8. 10.1097/HP.000000000000160010.1097/HP.0000000000001600 ↗
9. 10.1186/s40658-021-00378-310.1186/s40658-021-00378-3 ↗
10. 10.1021/acssensors.2c0260210.1021/acssensors.2c02602 ↗
11. 10.3390/s2305259910.3390/s23052599 ↗
12. 10.1038/s41566-023-01207-y10.1038/s41566-023-01207-y ↗
13. 10.1038/nphoton.2017.9410.1038/nphoton.2017.94 ↗
14. 10.1002/adfm.20230884410.1002/adfm.202308844 ↗
15. 10.1002/adfm.20190234610.1002/adfm.201902346 ↗
16. 10.1002/advs.20200209810.1002/advs.202002098 ↗
17. 10.1002/admt.20200047510.1002/admt.202000475 ↗
18. 10.1002/advs.20200258610.1002/advs.202002586 ↗
19. 10.1007/s40820-024-01393-610.1007/s40820-024-01393-6 ↗
20. 10.1002/admi.20230004410.1002/admi.202300044 ↗
21. 10.1126/sciadv.aay081510.1126/sciadv.aay0815 ↗
22. 10.1021/acsenergylett.2c0003110.1021/acsenergylett.2c00031 ↗
23. 10.1038/nphoton.2016.13910.1038/nphoton.2016.139 ↗
24. 10.1002/adom.20230084710.1002/adom.202300847 ↗
25. 10.1002/adom.20210114510.1002/adom.202101145 ↗
26. 10.1021/acs.nanolett.7b0147510.1021/acs.nanolett.7b01475 ↗
27. Knoll G. F. · 2011
28. N. US Department of Commerce NIST XCOM: Photon Cross Sections Database.http://www.nist.gov/pml/data/xcom/index.cfm2015.
29. 10.1063/5.015190210.1063/5.0151902 ↗