journal article·2019-07

Numerical neutron attenuation correction for partially-illuminated powder samples

Deon Marais, Zeldah N. Sentsho, Andrew M. Venter

Publisher page

Abstract

Abstract Chemical phase quantification from neutron diffraction measurements relies on accurate Bragg peak intensities at all diffraction angles. Amongst others these intensities are influenced by the total distance that the neutron beam has traversed through the sample in reaching the contributing volume segment and the distance from the contributing volume segment to the outer edge of the sample in the direction of the neutron detector. Since the total path length is dependent on the diffraction angle, gauge volume position inside the sample, as well as the sample dimensions and shape, the measured diffraction pattern should be corrected to account for this non-constant attenuation effect. Results show that in highly attenuation materials this can influence refined parameters during chemical phase quantification. A module was designed and integrated into the data reduction system ScanManipulator used at the neutron diffraction facility at the SAFARI-1 research reactor. The correction technique can further be used to accurately determine diffraction patterns obtained from position-resolved neutron diffraction experiments.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Nuclear Physics and Applications · Nuclear Materials and Properties · Nuclear reactor physics and engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Sears · Neutron News · 1992 · 3 · 2910.1080/10448639208218770 ↗
2. Pynn · 1990
3. Further refinement of the structure of WO310.1107/S0567740869004146 ↗
4. Richardson JW Jr 1993 Background modelling in Rietveld analysis. In RA Young (ed.) The Rietveld method IUCr, Oxford University Press 102–110.10.1093/oso/9780198555773.003.0006 ↗
5. The Beer-Lambert law10.1021/ed039p333 ↗
7. High-speed computation of the absorption correction for single crystal diffraction measurements10.1107/S0365110X57000584 ↗
8. Data processing at the south African Nuclear Energy Corporation SOC Ltd (Necsa) neutron diffraction facility
9. Marais
10. Gillies · 2018
11. MPISI: the neutron strain scanner materials probe for internal strain investigations at the SAFARI-1 research reactor10.1016/j.physb.2017.12.011 ↗
12. Alignment and calibration procedures of the Necsa neutron strain scanner10.21741/9781945291678-22 ↗
13. Marais · 2019
14. Thermal neutron cross section and transport properties of polyethylene10.1016/0168-9002(87)90370-6 ↗
15. Coelho · 2009
16. Crystal structure determination: a critical view10.1039/cs9841300157 ↗