Friction coefficient between FRP pultruded profiles and concrete
Source abstract
Abstract
This paper presents the experimental results of a direct shear test to determine the friction coefficient between fibre reinforced polymer (FRP) pultruded profiles and concrete. The FRP pultruded profile used in this study was glass fibre reinforced polymer (GFRP) I-section. The specimens were composed of a concrete block and a coupon of the GFRP pultruded profile. The experiment was conducted by using the direct shear test method. The parameters investigated included the type of concrete (self-compacting concrete and normal concrete) and the compressive strength of the concrete, as well as the different components (web and flange) of the I-section. The test results verify that the bond behaviour between the concrete and the GFRP pultruded profiles mainly depends on two factors, the friction stress and the adhesion stress. The friction coefficient between the FRP pultruded profiles and the concrete was between 0.5 and 0.6 when the normal stress fluctuated between 0.5 and 2 MPa, and the adhesion stress was about 0.2 MPa. The compressive strength of the concrete and the different components of the I-section have little effect on the friction coefficient, however, the type of the concrete significantly affects this coefficient.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Chen D, El-Hacha R (2011) Behaviour of hybrid FRP–UHPC beams in flexure under fatigue loading. Compos Struct 94(1):253–266. https://doi.org/10.1016/j.compstruct.2011.06.01610.1016/j.compstruct.2011.06.016 ↗
2. Guades E, Aravinthan T, Islam M, Manalo A (2012) A review on the driving performance of FRP composite piles. Compos Struct 94(6):1932–1942. https://doi.org/10.1016/j.compstruct.2012.02.00410.1016/j.compstruct.2012.02.004 ↗
3. Kwan WH, Ramli M (2013) Indicative performance of fiber reinforced polymer (FRP) encased beam in flexure. Constr Build Mater 48:780–788. https://doi.org/10.1016/j.conbuildmat.2013.07.01310.1016/j.conbuildmat.2013.07.013 ↗
4. Gonilha JA, Correia JR, Branco FA (2014) Structural behaviour of a GFRP-concrete hybrid footbridge prototype: experimental tests and numerical and analytical simulations. Eng Struct 60:11–22. https://doi.org/10.1016/j.engstruct.2013.12.01810.1016/j.engstruct.2013.12.018 ↗
5. Cosenza E, Manfredi G, Realfonzo R (1997) Behavior and modeling of bond of FRP rebars to concrete. J Compos Constr 1(2):40–5110.1061/(ASCE)1090-0268(1997)1:2(40) ↗
6. Achillides Z, Pilakoutas K (2004) Bond behavior of fiber reinforced polymer bars under direct pullout conditions. J Compos Constr 8(2):173–181. https://doi.org/10.1061/(ASCE)1090-0268(2004)8:2(173)10.1061/(ASCE)1090-0268(2004)8:2(173) ↗
7. Yuan JS, Hadi MNS (2017) Bond-slip behaviour between GFRP I-section and concrete. Compos B Eng 130:76–89. https://doi.org/10.1016/j.compositesb.2017.07.06010.1016/j.compositesb.2017.07.060 ↗
8. Berthet JF, Yurtdas I, Delmas Y, Li A (2011) Evaluation of the adhesion resistance between steel and concrete by push out test. Int J Adhes Adhes 31(2):75–83. https://doi.org/10.1016/j.ijadhadh.2010.11.00410.1016/j.ijadhadh.2010.11.004 ↗
9. Harajli M, Hamad B, Karam K (2002) Bond-slip response of reinforcing bars embedded in plain and fiber concrete. J Mater Civ Eng 14(6):503–511. https://doi.org/10.1061/(ASCE)0899-1561(2002)14:6(503)10.1061/(ASCE)0899-1561(2002)14:6(503) ↗
10. Tighiouart B, Benmokrane B, Gao D (1998) Investigation of bond in concrete member with fibre reinforced polymer (FRP) bars. Constr Build Mater 12(8):453–46210.1016/S0950-0618(98)00027-0 ↗
11. ABAQUS (2012) ABAQUS analysis user’s manual. Version 6.12
12. Rabbat BG, Russell HG (1985) Friction coefficient of steel on concrete or grout. J Struct Eng ASCE 111(3):505–51510.1061/(ASCE)0733-9445(1985)111:3(505) ↗
13. Correia JR, Branco FA, Ferreira JG (2007) Flexural behaviour of GFRP–concrete hybrid beams with interconnection slip. Compos Struct 77(1):66–78. https://doi.org/10.1016/j.compstruct.2005.06.00310.1016/j.compstruct.2005.06.003 ↗
14. Hadi MNS, Wang W, Sheikh MN (2015) Axial compressive behaviour of GFRP tube reinforced concrete columns. Constr Build Mater 81:198–207. https://doi.org/10.1016/j.conbuildmat.2015.02.02510.1016/j.conbuildmat.2015.02.025 ↗
15. Belzer B, Robinson M, Fick D (2013) Composite action of concrete-filled rectangular GFRP tubes. J Compos Constr 17(5):722–73110.1061/(ASCE)CC.1943-5614.0000370 ↗
16. Jiang T, Teng JG (2007) Analysis-oriented stress–strain models for FRP–confined concrete. Eng Struct 29(11):2968–2986. https://doi.org/10.1016/j.engstruct.2007.01.01010.1016/j.engstruct.2007.01.010 ↗
17. Kwan AKH, Dong CX, Ho JCM (2015) Axial and lateral stress–strain model for FRP confined concrete. Eng Struct 99:285–295. https://doi.org/10.1016/j.engstruct.2015.04.04610.1016/j.engstruct.2015.04.046 ↗
18. Lam L, Teng JG (2002) Strength models for fiber-reinforced plastic-confined concrete. J Struct Eng 128(5):612–623. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:5(612)10.1061/(ASCE)0733-9445(2002)128:5(612) ↗
19. Ozbakkaloglu T, Lim JC (2013) Axial compressive behavior of FRP-confined concrete: experimental test database and a new design-oriented model. Compos B Eng 55:607–634. https://doi.org/10.1016/j.compositesb.2013.07.02510.1016/j.compositesb.2013.07.025 ↗
20. Bakhshi M, Abdollahi B, Motavalli M, Shekarchizade M, Ghalibafian M (2007) The experimental modeling of GFRP confined concrete cylinders subjected to axial loads. In: Proceedings of the 8th international symposium on fiber reinforced polymer reinforcement for concrete Structures, Patras, Greece
21. Almusallam TH (2007) Behavior of normal and high-strength concrete cylinders confined with E-glass/epoxy composite laminates. Compos B Eng 38(5–6):629–639. https://doi.org/10.1016/j.compositesb.2006.06.02110.1016/j.compositesb.2006.06.021 ↗
22. Au C, Buyukozturk O (2005) Effect of fiber orientation and ply mix on fiber reinforced polymer-confined concrete. J Compos Constr 9(5):397–40710.1061/(ASCE)1090-0268(2005)9:5(397) ↗
23. ISO 527 (1997) Determination of tensile properties of plastics. Part 4: test conditions for isotropic and orthotropic fibre-reinforced plastic composites. European Committee for Standardization
24. ASTM D695 (2002) A standard test method for compressive properties of rigid plastics. ASTM international
25. Guades E, Aravinthan T, Islam MM (2014) Characterisation of the mechanical properties of pultruded fibre-reinforced polymer tube. Mater Des 63:305–315. https://doi.org/10.1016/j.matdes.2014.06.01810.1016/j.matdes.2014.06.018 ↗
26. Nunes F, Silvestre N, Correia JR (2016) Structural behaviour of hybrid FRP pultruded columns. Part 2: numerical study. Compos Struct 139:304–319. https://doi.org/10.1016/j.compstruct.2015.12.05910.1016/j.compstruct.2015.12.059 ↗
27. AS1012.09 (1999) Methods of testing concrete—determination of the compressive strength of concrete specimens. SAI Global database
28. Yao B, Li F, Wang X, Cheng G (2016) Evaluation of the shear characteristics of steel–asphalt interface by a direct shear test method. Int J Adhes Adhes 68:70–79. https://doi.org/10.1016/j.ijadhadh.2016.02.00510.1016/j.ijadhadh.2016.02.005 ↗
29. Kishida H, Uesugi M (1987) Tests of the interface between sand and steel in the simple shear apparatus. Géotechnique 37(1):45–52. https://doi.org/10.1680/geot.1987.37.1.4510.1680/geot.1987.37.1.45 ↗
30. Treadwell Australia Pty Ltd (2016) 58 Deeds Rd, North Plympton, SA Australia. http://www.treadwellgroup.com.au/ . Accessed 2 April 2016