journal article·2025-03Open access

How shearing affects air dissolution in fresh cement pastes under pressure

Daniel Galvez-Moreno, Dimitri Feys, Kyle Riding

Materials and Structures· Volume 58· Issue 2

Abstract

Abstract The air-void system of concrete is of paramount importance to ensure freeze–thaw durability. Pumping induces detrimental changes in the air-void system of concrete by dissolving the air bubbles in the surrounding water when pressure increases due to the pump action. This research work investigates the influence of shear rate and air-void size distribution on air dissolution with time of cement pastes under pressure. Steady-state shear rheology at different shear rates was applied on samples of different air-void size distributions but similar air contents. Due to the low capillary number of the mixtures, the application of pressure caused a decrease in viscosity. With increased applied shear rate and increased fineness of the air-void size distribution, the decrease in viscosity was more abrupt, indicating that the air dissolved almost immediately. Coarser air-void size distributions and lower shear rates caused a more gradual decrease in viscosity and thus a slower air dissolution. All experimental air dissolution times were lower than the calculated time needed for dissolution by pure diffusion. These results on the combined effect of pressure, duration, shear rate and air-void size distribution create the basis for a deeper understanding of the behavior of the air-void system of concrete during pumping.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete and Cement Materials Research · Innovations in Concrete and Construction Materials · Drilling and Well Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Pigeon M (1995) Durability of concrete in cold climates. CRC Press, London. https://doi.org/10.1201/978148227144710.1201/9781482271447 ↗
2. Neville AM (1995) Properties of concrete, 5th edn. Pearson, Harlow, UK
3. Powers TC (1968) Properties of fresh concrete. John Wiley and Sons. Inc., New York
4. Simon MJ, Jenkins RB, Hover KC (1992) Influence of immersion vibration on the void system of air-entrained concrete. Special Publication 131:99–126
5. Aïtcin, P. C., & Flatt, R. J. (Eds.). (2015). Science and technology of concrete admixtures. Woodhead Publishing.
6. Hover KC, Phares RJ (1996) Impact of concrete placing method on air content, air-void system parameters, and freeze-thaw durability. Transp Res Rec 1532(1):1–810.1177/0361198196153200101 ↗
7. M. Dyer. (1991) An investigation of concrete pumping and effects of pressure on the air void system of concrete.
8. Feys D, De Schutter G, Khayat KH, Verhoeven R (2016) Changes in rheology of self-consolidating concrete induced by pumping. Mater Struct 49(11):4657–467710.1617/s11527-016-0815-7 ↗
9. Macha, R. K., Zollinger, D. G., & Szecsy, R. (1994). Examination of Air Entrainment Stability Factors of Pumped Concrete. Texas Transportation Institute, Texas A & M University System.
10. Elkey, W., Janssen, D. J., & Hover, K. C. (1994). Concrete pumping effects on entrained air-voids. Final report (no. Wa-rd 313.1).
11. Pleau, R., Pigeon, M., Lamontagne, A., & Lessard, M. (1995). Influence of pumping on characteristics of air-void system of high-performance concrete. Transportation research record, 30–36.
12. Lessard M, Baalbaki M, Aitcin PC (1996) Effect of pumping on air characteristics of conventional concrete. Transp Res Rec 1532(1):9–1410.1177/0361198196153200102 ↗
13. Yazdani N, Bergin M, Mujtaba G (2000) Variations in the short-and long-term characteristics of bridge concrete due to transportation techniques. Transp Res Rec 1698(1):36–4410.3141/1698-06 ↗
14. Ksaibati K, Zeng M, Sellers FR, Dolan CW (2003) Air change in hydraulic concrete due to pumping. Transp Res Rec 1834(1):85–9210.3141/1834-11 ↗
15. Yingling J, Mullings GM, Gaynor RD (1992) Loss of air content in pumped concrete. Concr Int 14(10):57–61
16. Riding, K. A., Vosahlik, J., Feys, D., Malone, T. R., & Lindquist, W. (2016). Best practices for concrete pumping (No. K-TRAN: KSU-14–2). Kansas. Dept. of Transportation.
17. Vosahlik J, Riding KA, Feys D, Lindquist W, Keller L, Van Zetten S, Schulz B (2018) Concrete pumping and its effect on the air void system. Mater Struct 51(4):9410.1617/s11527-018-1204-1 ↗
18. Wang LK, Shammas NK, Selke WA, Aulenbach DB (2010) Gas dissolution, release, and bubble formation in flotation systems. In: Wang LK, Shammas NK, Selke WA, Aulenbach DB (eds) Flotation technology. Humana Press, Totowa, NJ, pp 49–83. https://doi.org/10.1007/978-1-60327-133-2_210.1007/978-1-60327-133-2_2 ↗
19. Du L, Folliard KJ (2005) Mechanisms of air entrainment in concrete. Cem Concr Res 35(8):1463–147110.1016/j.cemconres.2004.07.026 ↗
20. Guggenheim EA (1985) Thermodynamics-an advanced treatment for chemists and physicists. North-Holland, Amsterdam
21. Myers D (1999) Surfaces, interfaces, and colloids, vol 415. Wiley, New York
22. Epstein PS, Plesset MS (1950) On the stability of gas bubbles in liquid-gas solutions. J Chem Phys 18(11):1505–150910.1063/1.1747520 ↗
23. Kaplan, D. (2001). Pompage des bétons, Laboratoire Central des Ponts et Chaussées, 2001.
24. Feys D, Khayat KH, Perez-Schell A, Khatib R (2014) Development of a tribometer to characterize lubrication layer properties of self-consolidating concrete. Cement Concr Compos 54:40–5210.1016/j.cemconcomp.2014.05.008 ↗
25. Feys D, De Schutter G, Verhoeven R (2013) Parameters influencing pressure during pumping of self-compacting concrete. Mater Struct 46(4):533–55510.1617/s11527-012-9912-4 ↗
26. Favelukis M, Tadmor Z, Talmon Y (1995) Bubble dissolution in viscous liquids in simple shear flow. AIChE J 41(12):2637–264110.1002/aic.690411213 ↗
27. Favelukis M, Tadmor Z, Semiat R (1999) Bubble growth in a viscous liquid in a simple shear flow. AIChE J 45(4):691–69510.1002/aic.690450404 ↗
28. Tattersall GH, Banfill PF (1983) The rheology of fresh concrete. Pitman, London
29. Wallevik OH, Gjørv OE (1990) Modification of the two-point workability apparatus. Mag Concr Res 42(152):135–14210.1680/macr.1990.42.152.135 ↗
30. Wallevik OH, Wallevik JE (2011) Rheology as a tool in concrete science: the use of rheographs and workability boxes. Cem Concr Res 41(12):1279–128810.1016/j.cemconres.2011.01.009 ↗
31. Papo A (1988) Rheological models for cement pastes. Mater Struct 21:41–4610.1007/BF02472527 ↗
32. Struble L, Sun GK (1995) Viscosity of Portland cement paste as a function of concentration. Adv Cem Based Mater 2(2):62–6910.1016/1065-7355(95)90026-8 ↗
33. Carlsward J, Emborg M, Utsi S, Oberg P (2003) Effects of constituents on the workability and rheology of self-compacting concrete. In: Wallevik OH, Nielsson I (eds) The 3rd International RILEM Symposium on Self-Compacting Concrete. RILEM Publications SARL, Bagneux, France (pp, pp 143–153
34. Chia KS, Chen-Chung K, Min-Hong Z (2005) Stability of fresh lightweight aggregate concrete under vibration. ACI Mater J 102(5):347
35. Rust AC, Manga M (2002) Effects of bubble deformation on the viscosity of dilute suspensions. J Nonnewton Fluid Mech 104(1):53–6310.1016/S0377-0257(02)00013-7 ↗
36. Struble LJ, Jiang Q (2004) Effects of air entrainment on rheology. Mater J 101(6):448–456
37. Krieger IM (1972) Rheology of monodisperse latices. Adv Coll Interface Sci 3(2):111–13610.1016/0001-8686(72)80001-0 ↗
38. Hover K (1995) Investigating effects of concrete handling on air content. Concrete Constr 40(3):745–749
39. Li X, Fu Z, Luo Z (2015) Effect of atmospheric pressure on air content and air void parameters of concrete. Mag Concr Res 67(8):391–40010.1680/macr.14.00256 ↗
40. Lyu K, Garboczi EJ, Gao Y, Miao C, Liu X (2022) Relationship between fine aggregate size and the air void system of six mortars: I. Air void content and diameter distribution. Cement Concrete Compos 131:10459910.1016/j.cemconcomp.2022.104599 ↗
41. Fantous T, Yahia A (2020) Air-void characteristics in highly flowable cement-based materials. Constr Build Mater 235:11745410.1016/j.conbuildmat.2019.117454 ↗
42. ASTM C150 / C150M-20, Standard Specification for Portland Cement, ASTM International, West Conshohocken, PA, 2020, www.astm.org
43. Ferraris CF, Gaidis JM (1992) Connection between the rheology of concrete and rheology of cement paste. Mater J 89(4):388–393
44. Geiker MR, Brandl M, Thrane LN, Nielsen LF (2002) On the effect of coarse aggregate fraction and shape on the rheological properties of self-compacting concrete. Cement, Concrete Aggreg 24(1):3–610.1520/CCA10484J ↗
45. Zeng X, Lan X, Zhu H, Liu H, Umar HA, Xie Y, Long G, Ma C (2020) A review on bubble stability in fresh concrete: mechanisms and main factors. Materials 13(8):182010.3390/ma13081820 ↗
46. Rosen MJ, Kunjappu JT (2012) Surfactants and interfacial phenomena. John Wiley & Sons10.1002/9781118228920 ↗
47. ASTM C305–20, Standard Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency, ASTM International, West Conshohocken, PA, 2020, www.astm.org
48. ASTM C1437–20, Standard Test Method for Flow of Hydraulic Cement Mortar, ASTM International, West Conshohocken, PA, 2020, www.astm.org
49. Gálvez-Moreno D, Feys D, Riding K (2019) Characterization of air dissolution and reappearance under pressure in cement pastes by means of rheology. Front Mater 6:7310.3389/fmats.2019.00073 ↗
50. Einstein A (1906) Eine neue Bestimmung der Moleküldimensionen. Ann Phys 19:289–30610.1002/andp.19063240204 ↗
51. Einstein A (1911) Berichtigung zu meiner Arbeit: „Eine neue Bestimmung der Moleküldimensionen“. Ann Phys 34:591–59210.1002/andp.19113390313 ↗
52. Tunstall LE, Ley MT, Scherer GW (2021) Air entraining admixtures: mechanisms, evaluations, and interactions. Cem Concr Res 150:10655710.1016/j.cemconres.2021.106557 ↗
53. Macosko CW (1994) Rheology principles. Wiley-VCH, Measurements and Applications