Abstract

In order to consider the response of concrete columns confined by FRP and FRCM system, proper models have to be formulated. In this context the present paper shows a generalized criterion for the determination of the increase in strength, in ductility and in dissipated energy for varying corner radius ratio of the cross section and fiber volumetric ratio. The procedure is based on the best fitting of several experimental data and unlike the usual empirical approaches available in the literature, the proposed technique relates the confinement effectiveness to a single parameter representative of the relative stiffness between the original concrete core and the reinforcement system. Furthermore, the proposed analytical models overcomes the limit of many empirical or semi-empirical models given in the literature that are applicable only to specific cases. A comparison with same available models confirm the reliability of the proposed procedure.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Campione G, Colajanni P, La Mendola L, Spinella N (2007) Ductility of R.C. members externally wrapped with frp sheets. J Compos Constr 11(3):279–29010.1061/(ASCE)1090-0268(2007)11:3(279) ↗
2. Xiao Y, Wu H (2000) Compressive behavior of concrete confined by carbon fiber composite jackets. J Mater Civil Eng 12(2):139–14610.1061/(ASCE)0899-1561(2000)12:2(139) ↗
3. Pessiki S, Harries KA, Kestner JT, Sause R, Ricles JM (2001) Axial behavior of reinforced concrete columns confined with FRP jackets. ASCE J Compos Constr 5(4):237–24510.1061/(ASCE)1090-0268(2001)5:4(237) ↗
4. Lam L, Teng JG (2003) Design-oriented stress–strain model for FRP-confined concrete. Constr Build Mater 17(6–7):471–48910.1016/S0950-0618(03)00045-X ↗
5. Mirmiran A, ShahawyM Samaan M, El-Echary H (1998) Effect of column parameters on FRP confined concrete. ASCE J Compos Constr 2(4):175–18510.1061/(ASCE)1090-0268(1998)2:4(175) ↗
6. Lam L, Teng JG (2004) Ultimate condition of fiber reinforced polymer-confined concrete. J Compos Constr 8(6):539–54810.1061/(ASCE)1090-0268(2004)8:6(539) ↗
7. Wang L-M, Wu Y-F (2008) Effect of corner radius on the performance of CFRP-confined square concrete column: test. J Eng Struct 30(2):493–50510.1016/j.engstruct.2007.04.016 ↗
8. Lam L, Teng JG, Cheung CH, Xiao Y (2006) FRP-confined concrete under cyclic axial compression. Cement Concr Compos 28(10):948–958
9. Jiang T, Teng JG (2007) Analysis-oriented stress–strain models for FRP-confined concrete. Eng Struct 29(11):2968–298610.1016/j.engstruct.2007.01.010 ↗
10. CNR-DT200 (2004) Guide for the design and construction of externally bonded FRP systems for strengthening existing structures (Materials, RC and PC Structures, masonry structures). CNR, National Research Council, Rome, Italy
11. ACI Committee 440 (2008) Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. ACI 440.2R-08, American Concrete Institute, Farmington Hills
12. Fédérationinternationale du Béton (fib). Externally bonded FRP reinforcement for RC structures. Bulletin no. 14, technical tep. Lausanne, Switzerland
13. Kurtz S, Balagru P (2001) Comparison of inorganic and organic matrices for strengthening of RC beams with carbon sheets. J Struct Eng ASCE 127(1):35–4210.1061/(ASCE)0733-9445(2001)127:1(35) ↗
14. Wu HC, Teng J (2003) Concrete confined with fiber reinforced cement based thinsheet composites. In: Tan KH (ed) FRPRCS-6 fiber reinforced polymer reinforcement for concrete structures, vol 1. World Scientific Publishing Co., Singapore, pp 591–600
15. Triantafillou TC, Papanicolaou CG, PanagiotisZissimopoulos P, Laourdekis T (2006) Concrete confinement with textile-reinforced mortar jackets. ACI Struct J 103(1):28–37
16. Bournas DA, Lontou PV, Papanicolaou CG, Triantafillou TC (2007) Textile-reinforced mortar versus fiber-reinforced polymer confinement in reinforced concrete columns. ACI Struct J 104(6):740–748
17. Ombres L (2007) Confinement effectiveness in concrete strengthened with fiber reinforced cement based composite jackets. FRPCS-8. Patras, Greece
18. y Basalo FJDC, Matta F, Nanni A (2012) Fiber reinforced cement-based composite system for concrete confinement. Constr Build Mater 32:55–6510.1016/j.conbuildmat.2010.12.063 ↗
19. Colajanni P, De Domenico F, Recupero A, Spinella A (2014) Concrete columns confined with fiber reinforced cementitious mortars: experimentation and modelling. Constr Build Mater 52:375–38410.1016/j.conbuildmat.2013.11.048 ↗
20. Trapko T (2013) Fiber reinforced cementitious matrix confined concrete elements. Mater Des 44:382–39110.1016/j.matdes.2012.08.024 ↗
21. Rochette P, Labossiere P (2000) Axial testing of rectangular column models confined with composites. ASCE J Compos Constr 4(3):129–13610.1061/(ASCE)1090-0268(2000)4:3(129) ↗
22. Yang X, Wei J, Nanni A, Dharani LR (2004) Shape effect onthe performance of carbon fiber reinforced polymer wraps. ASCE J Compos Constr 8(5):444–45110.1061/(ASCE)1090-0268(2004)8:5(444) ↗
23. Mander JB, Priestley MJN, Park R (1988) Theoretical stress–strain model for confined concrete. ASCE J Struct Div 107(ST11):2227–2244
24. Pellegrino C, Modena C (2010) Analytical model for FRP confinement of concrete columns with and without internal steel reinforcement. J Compos Constr 14(6):693–70510.1061/(ASCE)CC.1943-5614.0000127 ↗
25. Campione G, Miraglia N (2003) Strength and strain capacities of concrete compression members reinforced with FRP. Cem Concr Compos 25(1):31–4110.1016/S0958-9465(01)00048-8 ↗
26. Mostofinejad D, Moshiri N, Mortazavi N (2015) Effect of corner radius and aspect ratio on compressive behavior of rectangular concrete columns confined with CFRP. Mater Struct 48(1–2):107–12210.1617/s11527-013-0171-9 ↗
27. Harries KA, Carey SA (2003) Shape and ‘‘gap’’ effects on the behavior of variably confined concrete. Cem Concr Res 33(6):881–89010.1016/S0008-8846(02)01085-2 ↗
28. Bullo S (2003) Experimental study of the effects of the ultimate strain of fiber reinforced plastic jackets on the behavior of confined concrete. In: Proceedings of the international conference “composites in construction”. Cosenza; Italy, pp 465–70
29. Cui C (2009) Behaviour of normal and high strength concrete confined with fibre reinforced polymers (FRP). MSc Thesis, University of Toronto, pp 1–376
30. Colajanni P, Fossetti M, Macaluso G (2014) Effects of confinement level, cross-section shape and corner radius on the cyclic behavior of CFRCM confined concrete columns. Constr Build Mater 55:379–38910.1016/j.conbuildmat.2014.01.035 ↗
31. De Lorenzis L, Tepfers R (2003) Comparative study of models on confinement of concrete cylinders with fiber reinforced polymer composites. J. Compos Constr 7(3):219–23710.1061/(ASCE)1090-0268(2003)7:3(219) ↗
32. Rousakis TC, Karabinis AI, Kiousis PD (2007) FRP-confined concrete members: axial compression experiments and plasticity modelling. Eng Struct 29(7):1343–135310.1016/j.engstruct.2006.08.006 ↗
33. Wu Y-F, Wei Y-Y (2010) Effect of cross-sectional aspect ratio on the strength of CFRP-confined rectangular concrete columns. Eng Struct 32(1):32–4510.1016/j.engstruct.2009.08.012 ↗
34. Ombres L (2014) Concrete confinement with a cement based high strength composite material. Compos Struct 109:294–30410.1016/j.compstruct.2013.10.037 ↗
35. Matthys S, Taerwe L, Audenaert K (1999) Tests on axially loaded concrete columns confined by fiber reinforced polymer sheet wrapping. In: Proceedings of the fourth international symposium on fiber reinforced polymer reinforcement for reinforced concrete structures, ACI SP-188, Michigan, USA
36. Karabinis A, Rousakis TC (2001) Carbon FRP confined concrete elements under axial load. In: FRP composites in civil engineering conference, pp 309–316
37. Spoelstra MR, Monti G (1999) FRP-confined concrete model. ASCE J Compos Constr 3(3):143–15210.1061/(ASCE)1090-0268(1999)3:3(143) ↗
38. Di Ludovico M, Prota A, Manfredi G (2010) Structural upgrade using basalt fibers for concrete confinement. ASCE J Compos Constr 14(5):541–55210.1061/(ASCE)CC.1943-5614.0000114 ↗