Measurement of moisture content in solid brick walls using timber dowel
Source abstract
Abstract
Moisture within walls can have a serious detrimental impact on buildings and undermine their long-term durability and integrity. This paper investigates the accuracy of the timber dowel method for measuring wall moisture content in a solid brick wall. The timber dowel is inserted in the wall and removed at intervals and moisture readings obtained using a resistance-based, moisture-meter. The moisture content of timber dowels and the surrounding brick and mortar in a laboratory wall is measured and compared to the moisture content in the timber dowel, brick and mortar in different relative humidity environments (saturated salt solutions). The paper finds that a linear relationship of increasing moisture content in the dowel and laboratory wall is observed. At medium dowel moisture content (dowel moisture content >15 %), the moisture content in the dowel, brick and mortar is similar in both the laboratory wall and the RH environments. At higher moisture content there is a divergence whereby at the same dowel moisture content, the laboratory brick and mortar show higher moisture contents than those achieved in the RH environments. It appears that liquid water present in the wall has difficulty transferring to the dowel and consequently the dowel underestimates at high moisture contents. It is concluded that the dowel gives a good indication of the moisture content in the wall when the dowel readings are not higher than 15 % and indicates changes in relative wetness above this. In-situ monitoring of the moisture content of a nineteenth century brick wall following the application of lime plaster showed expected changes in moisture content. An increase in wall moisture content following the application of the plaster and the wall returned to its original moisture state by 9 months.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Building materials and conservation · Hygrothermal properties of building materials · Masonry and Concrete Structural Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Sass O, Viles HA (2006) How wet are these walls? Testing a novel technique for measuring moisture in ruined walls. J Cult Herit 7:257–26310.1016/j.culher.2006.08.001 ↗
2. Uddin M, Mufti A, Polyzois D, Shrive N, Jaeger L, Stephenson D, Duchesne D, Paquette J (2009) Monitoring moisture levels in stone masonry using Duff gauge sensors. In: Proceedings of the 4th international conference on structural health monitoring on intelligent infrastructure (SHMII-4), Zurich, Switzerland
3. Ueno K, Straube J (2008) Laboratory calibration and field results of wood resistance humidity sensors. In: Proceedings of BEST 1 conference, Minneapolis
4. Said MN (2004) Moisture measurement guide for building envelope applications. Research Report 190. Building Envelope and Structure Program, Institute for Research in Construction, National Research Council Canada
5. Larsen PK (2004) Moisture measurement in Tirsted Church. J Arch Conserv 1(10):22–35
6. Hansen MH (2005) Measurement of moisture content in basement brick walls—a comparison of different methods. In: Proceedings of the 7th Nordic building physics symposium, Icelandic Building Research Institute, & Royal Institute of Technology, Reykjavik, Iceland
7. Pel L, Huinink H, Kopinga K (2002) Ion transport and crystallization in inorganic building materials as studied by nuclear magnetic resonance. Appl Phys Lett 81(15):2893–289510.1063/1.1512329 ↗
8. Healy W, Luo S, Evans M, Sucheta A, Liu Y (2003) Development of an optical fiber-based moisture sensor for building envelopes. In: Proceedings of the 24th AIVC conference & BETEC conference—ventilation, humidity control and energy, Washington DC
9. Ridout B (2000) Timber decay in buildings: the conservation approach to treatment. E & F Spon, London
10. Duff JE (1966) A probe for accurate determination of moisture content of wood products in use. Research Note FPL-0142. Forest Products Laboratory, Forest Service, US Department of Agriculture, Madison
11. Nordtest (1993) Building materials, wood: moisture content. Nordtest method, NT Build 420. Nordtest, Espoo
12. Brandt E, Hansen MH (1999) Measuring moisture content in wood with built in probes 20+ years of experience. In: Proceedings of the durability of building materials and components 8, Vancouver, Canada
13. Rasmussen TV (2005) Moisture conditions for organic and mineral-based insulation products used in exterior walls and attics in traditional Danish dwellings. In: Proceedings of the 7th symposium on building physics in the Nordic countries, The Icelandic Building Research Institute, Reykjavik, Iceland
14. Fugler D (1996) Straw bale moisture sensor study. Research & Development Highlights. Canada Mortgage and Housing Corporation (CMHC), Ottawa
15. Goodhew S, Griffiths R, Woolley T (2004) An investigation of moisture content in the walls of a straw-bale building. Build Environ J 39:1443–145110.1016/j.buildenv.2004.04.003 ↗
16. Carfrae J, De Wilde P, Littlewood J, Goodhew S, Walker P (2011) Development of a cost effective probe for the long term monitoring of straw bale buildings. Build Environ 46(1):156–16410.1016/j.buildenv.2010.07.010 ↗
17. Ülker U (2003) Comparative study of wood density by specific amount of void volume (porosity). Turk J Agric For 27(1):1–6
18. Plötze M, Niemz P (2011) Porosity and pore size distribution of different wood types as determined by mercury intrusion porosimetry. Eur J Wood Wood Prod 69(4):649–65710.1007/s00107-010-0504-0 ↗
19. James WL (1988) Electric moisture meters for wood. General Technical Report FPL-GTR-6. United States Department of Agriculture Forest Service Forest Products Laboratory, Madison10.2737/FPL-GTR-6 ↗
20. Greenspan L (1977) Humidity fixed points of binary saturated aqueous solutions. J Res Natl Bur Stand 81A(1):89–9610.6028/jres.081A.011 ↗
21. ISO 12571:2013 (2013) Hygrothermal performance of building materials and products—determination of hygroscopic sorption properties. ISO, Geneva
22. Brunauer S, Emmet PH, Teller E (1938) Adsorption of gases in multimolecular layers. J Am Chem Soc 60:309–31910.1021/ja01269a023 ↗
23. Hansen KK (1986) Sorption isotherms—a catalogue. Technical Report 162/86. Building Materials Laboratory, The Technical University of Denmark, Kgs. Lyngby