Abstract

Structural sandwich panels using thin high performance concrete (HPC) plates offer a possibility to address the modern environmental challenges faced by the construction industry. Fire resistance is a major necessity in structures using HPC. This paper presents experimental studies at elevated temperatures for panels with 30 mm thick plates stiffened by structural ribs, thick insulation layers, and steel shear connecting systems. Parametric variation assessing the role of each component of the sandwich structure was performed on unloaded specimens of reduced size. Full size walls were tested with load. Tests were performed in standard furnaces, following the conditions of REI certification tests. Unloaded specimens successfully passed tests. Loaded specimens met the R and I requirements, failing E due to sustained flaming of the insulation. They exhibited multiple cracking of their exposed plate and one of them experienced heavy heat-induced spalling. Results highlighted insulation shear failure from differential thermal expansion at the interface with concrete. It suggests the existence of a high bond level between the two materials which might allow structural applications at early age. Cracks resulted from buckling and thermal bowing, present in the upper and lower parts of the panel. Shear connectors created stress concentrations leading to local failure. Only ribs were found to have a structural role, the plate being largely negligible and solely protecting the insulation from heat. Performance could be enhanced by using thicker plates (50 mm).
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Engineering and Material Science Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Gara F, Ragni L, Roia D, Dezi L (2012) Experimental tests and numerical modelling of wall sandwich panels. Eng Struct 37:193–20410.1016/j.engstruct.2011.12.027 ↗
2. Benayoune A, Samad AAA, Trikha DN, Ali AAA, Ashrabov AA (2006) Structural behaviour of eccentrically loaded precast sandwich panels. Constr Build Mater 20:713–72410.1016/j.conbuildmat.2005.02.002 ↗
3. Morcous G, Tadros MK, Lafferty M, Gremel D (2010) Optimised NU sandwich panel system for energy, composite action and production efficiency. Proceedings 3rd FIB international congress, Washington DC
4. Lameiras R, Barros J, Valente IB, Azenha M (2013) Development of sandwich panels combining fibre reinforced concrete layers and fibre reinforced polymer connectors. Part I: conception and pull-out tests. Compos Struct 105:446–45910.1016/j.compstruct.2013.06.022 ↗
5. Hodicky K, Hulin T, Schmidt JW, Stang H (2013) Structural performance of new thin-walled concrete sandwich panel system reinforced with BFRP shear connectors. In: Proceedings 4th Asia-pacific conference on FRP in structures (APFIS 2013), Melbourne, pp 11–13
6. Bisby L, Gales J, Maluk C (2013) A contemporary review of large-scale non-standard structural fire testing. Fire Sci Rev 2:1–2710.1186/2193-0414-2-1 ↗
7. Kodur VKR, Naser MZ (2013) Importance factor for design of bridges against fire hazard. Eng Struct 54:207–22010.1016/j.engstruct.2013.03.048 ↗
8. Lange D, Sjöström J, Jansson R, Boström L (2012) Deflection of concrete floor slab during a fire test: test and modelling. In: Proceedings 15th international conference on experimental mechanics: fire symposium, Porto, pp 22–27
9. Babrauskas V (1997) Sandwich panel performance in full-scale and bench-scale fire tests. Fire Mater 21:53–6510.1002/(SICI)1099-1018(199703)21:2<53::AID-FAM593>3.0.CO;2-8 ↗
10. EN 13501-2: Fire classification of construction products and building elements—Part 2: classification using data from fire resistance tests, excluding ventilation services
11. Kalifa P, Menneteau FD, Quenard D (2000) Spalling and pore pressure in HPC at high temperatures. Cem Concr Res 30:1915–192710.1016/S0008-8846(00)00384-7 ↗
12. Hertz KD (2003) Limits of spalling of fire-exposed concrete. Fire Saf J 38:103–11610.1016/S0379-7112(02)00051-6 ↗
13. Bažant ZP (1997) Analysis of pore pressure, thermal stress and fracture in rapidly heated concrete. In: Proceedings international workshop on fire performance of high-strength concrete, NIST, Gaithersburg, pp 13–14
14. Khoury GA (2000) Effect of fire on concrete and concrete structures. Prog Struct Eng Mater 2:429–44710.1002/pse.51 ↗
15. Phan LT (2008) Pore pressure and explosive spalling in concrete. Mater Struct 41:1623–163210.1617/s11527-008-9353-2 ↗
16. Zeiml M, Leithner D, Lackner R, Mang HA (2006) How do polypropylene fibres improve the spalling behaviour of in situ concrete? Cem Concr Res 36:929–94210.1016/j.cemconres.2005.12.018 ↗
17. Khoury GA (2008) Polypropylene fibres in heated concrete. Part 2: pressure relief mechanisms and modelling criteria. Mag Concr Res 60:189–20410.1680/macr.2007.00042 ↗
18. Knack I (2011) The use of PP fibres in tunnel construction to avoid explosive concrete spalling in case of fire. New test results for the clarification of the mode of action. In: Proceedings 2nd international RILEM workshop on concrete spalling due to fire exposure, Delft, pp 5–7
19. Schneider U (1988) Concrete at high temperatures—a general review. Fire Saf J 13:55–6810.1016/0379-7112(88)90033-1 ↗
20. Kodur VKR, Dwaikat M, Fike R (2010) High-temperature properties of steel for fire resistance modelling of structures. ASCE J Mater Civ Eng 22:423–43410.1061/(ASCE)MT.1943-5533.0000041 ↗
21. Hager I, Pimienta P (2004) The impact of the addition of polypropylene fibres on the mechanical properties of high performance concrete exposed to high temperatures. In: Proceedings 6th international RILEM symposium on fibre-reinforced concretes (BEFIB’2004), Varenna, pp 20–22
22. Behnood A, Ghandehari M (2009) Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibres heated to high temperatures. Fire Saf J 44:1015–102210.1016/j.firesaf.2009.07.001 ↗
23. Rizkalla SH, Hassan TK, Lucier G (2009) FRP shear transfer mechanism for precast, prestressed concrete sandwich load-bearing panels. ACI Spec Publ 265:603–625
24. Einea A, Salmon DC, Tadros MK, Culp T (1994) A new structurally and thermally efficient precast sandwich panel system. PCI J 39:90–10110.15554/pcij.07011994.90.101 ↗
25. EN 1363-1: Fire resistance tests—Part 1: general requirements
26. ISO 834-1: Fire resistance tests
27. Hulin T, Lauridsen D, Hodicky K, Schmidt JW, Stang H (2015) Influence of basalt FRP mesh reinforcement on high performance concrete thin plates at high temperatures. J Compos Constr. doi: 10.1061/(ASCE)CC.1943-5614.000054610.1061/(ASCE)CC.1943-5614.0000546 ↗