journal article·2022-10Open access

Fire induced concrete spalling in combination with size effects

André Klimek, Ludwig Stelzner, Sascha Hothan, Andreas Rogge

Materials and Structures· Volume 55· Issue 8

Abstract

Abstract The size effect has its origin in fracture mechanics and describes the formation as well as propagation of cracks in brittle and solid materials in dependence of the specimen size. However, the size effect in concrete spalling describes the damage behaviour on a macroscopic scale for different sized specimens in case of fire. Concrete spalling is a very complex and yet not fully understood phenomenon. To reduce the effort of fire tests to analyse the spalling behaviour of concrete mixtures, this study investigates the susceptibility to spalling for six different concrete mixtures and three specimen sizes. The sizes were divided in full scale slabs (1.8 m × 1.2 m × 0.3 m), intermediate scale cuboids (0.6 m × 0.6 m × 0.3 m) and small scale cylinders (Ø0.15 m × 0.3 m). For this purpose, a novel test set-up was built to test six intermediate scale or twelve small scale specimens simultaneously to ensure a similar heating regime for every specimen. All specimens were fire exposed on one side and remained unrestrained. A size effect occurred for four of the six concrete mixtures. Compared to the full scale specimens the spalling was reduced significantly for all smaller specimen sizes. Additionally, spalling did not occur for the small scale specimens. The results show that the specimen size is an essential parameter to investigate the susceptibility to spalling of a concrete mixture. For future investigations the testing conditions must be adjusted for the intermediate scale specimens to recreate the conditions of the slabs.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Engineering and Material Science Research · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Kirkland CJ (2002) The fire in the channel tunnel. Tunn Undergr Space Technol 17(129):132
2. Jansson R, Boström L (2013) Factors influencing fire spalling of self compacting concrete. Mater Struct 46:1683–169410.1617/s11527-012-0007-z ↗
3. Lo Monte F, Felicetti R, Rossino C (2019) Fire spalling sensitivity of high-performance concrete in heated slabs under biaxial compressive loading. Mater Struct 52:14. https://doi.org/10.1617/s11527-019-1318-010.1617/s11527-019-1318-0 ↗
4. Kalifa P, Menneteau FD, Quenard D (2000) Spalling and pore pressure in HSC at high temperatures. Cem Concr Res 30:1915–192710.1016/S0008-8846(00)00384-7 ↗
5. Kordina K (2003) Brände in unterirdischen Verkehrsanlagen. Bautechnik 80:327–33810.1002/bate.200302620 ↗
6. Stelzner L, Powierza B, Tyler O, Dlugosch R, Weise F (2019) Thermally-induced moisture transport in high performance concrete studied by X-ray-CT and 1H-NMR. Constr Build Mater 224:600–60910.1016/j.conbuildmat.2019.07.065 ↗
7. Harmathy TZ (1965) Effect of moisture on the fire endurance of building elements. Am Soc Test Mater Spec Tech Publ 385:74–95
8. Cruz CR, Gillen M (1980) Thermal Expansion of Portland cement paste, mortar and concrete at high temperatures. Fire Mater 4:66–7010.1002/fam.810040203 ↗
9. Schneider U (1982) Behaviour of concrete at high temperatures. Deutscher Ausschuss für Stahlbeton 337
10. Bažant ZP, Sener S, Prat PC (1988) Size effect tests of torsional failure of plain and reinforced concrete beams. Mater Struct 21:425–43010.1007/BF02472322 ↗
11. Ožbolt J (1995) Maßstabseffekt und Duktilität von Beton- und Stahlbetonkonstruktionen. Universität Stuttgart, Habilitation
12. Hoover CG, Bažant ZP (2014) Universal size-shape effect law based on comprehensive concrete fracture tests. J Eng Mech 140:473–479. https://doi.org/10.1061/(ASCE)EM.1943-7889.000062710.1061/(ASCE)EM.1943-7889.0000627 ↗
13. Bažant ZP (1984) Size effect in blunt fracture: concrete, rock, metal. J Eng Mech 110:518–53510.1061/(ASCE)0733-9399(1984)110:4(518) ↗
14. Boström L, Wickström U, Adl-Zarrabi B (2007) Effect of specimen size and loading conditions on spalling of concrete. Fire Mater 31:173–18610.1002/fam.931 ↗
15. Mohaine S, Boström L, Lion M, McNamee R, Robert F (2019) Cross-comparison of screening tests for spalling of concrete. Fire Mater 2021:1–14. https://doi.org/10.1002/fam.294610.1002/fam.2946 ↗
16. Mohd Ali AZ, Sanjayan J, Guerrieri M (2018) Specimen size, aggregate size, and aggregate type effect on spalling of concrete in fire. Fire Mater 42:59–6810.1002/fam.2457 ↗
17. Guerrieri M, Fragomeni S (2016) Mechanisms of spalling in concrete panels of different geometry in hydrocarbon fire. J Mater Civ Eng 12:1–12. https://doi.org/10.1061/(ASCE)MT.1943-5533.000168010.1061/(ASCE)MT.1943-5533.0001680 ↗
18. Pimienta P, Moreau B, Avenel R, Peyrac P, Taillefer N, Larive C, D’Aloia L, Clec’h P (2013) Spalling tests on embedded cores and slabs: a comparative study. MATEC Web conferences 6. https://doi.org/10.1051/matecconf/2013060100310.1051/matecconf/20130601003 ↗
19. Lo Monte F, Felicetti R, Meda A, Bortolussi A (2019) Assessment of concrete sensitivity to fire spalling: a multi-scale experimental approach. Constr Build Mater 212:476–48510.1016/j.conbuildmat.2019.03.332 ↗
20. Werner S, Rogge A (2015) The effect of various fire-exposed surface dimensions on the spalling of concrete specimens. Fire Mater 39:545–55610.1002/fam.2256 ↗
21. Zhao R, Sanjayan JG (2009) Test method for concrete spalling using small electric furnace. Fire Mater 34:189–201. https://doi.org/10.1002/fam.102010.1002/fam.1020 ↗
22. Hertz KD, Sørensen LS (2005) Test method for spalling of fire exposed concrete. Fire Saf J 40:466–47610.1016/j.firesaf.2005.04.001 ↗
23. Ozawa M, Tanibe T, Kamata R, Uchida Y, Rokugo K, Parajuli SS (2018) Behavior of ring-restrained high-performance concrete under extreme heating and developement of screening tests. Constr Build Mater 162:215–22810.1016/j.conbuildmat.2017.11.144 ↗
24. Stelzner L (2021) Analyse des thermisch induzierten Feuchtetransports in gefügedichten Betonen. Dissertation, Universität Stuttgart
25. Dehn F, Werther N, Knitl J (2006) Großbrandversuche für den City-Tunnel Leipzig. Beton- und Stahlbetonbau 101(8):631–636. https://doi.org/10.1002/best.20060818610.1002/best.200608186 ↗
26. Hager I, Mróz K, Tracz T (2018) Concrete propensity to fire spalling: testing and observations. MATEC Web of Conferences 163. https://doi.org/10.1051/matecconf/20181630200410.1051/matecconf/201816302004 ↗
27. Brecht K, Pistol K, Klemmstein F, Rogge A (2017) Novel test setup for the quantification of the size effect in spalling tests. In: 5th international RILEM workshop on concrete spalling due to fire exposure, Borås, Sweden
28. Zusätzliche Technische Vertragsbedingungen und Richtlinien für Ingenieurbauten ZTV-Ing. Teil 5 Tunnelbau. Bundesamt für Straßenwesen 2014
29. Eurocode 1: Actions on structures - Part1-2: General actions - Actions on structures exposed to fire; German version EN 1991-1-2:2002, September 2003
30. Pistol K, Weise F, Meng B (2012) Polypropylen-Fasern in Hochleistungsbeton. Beton- und Stahlbetonbau 107:476–48310.1002/best.201200024 ↗
31. Eurocode 2, 1992-1-2: Design of concrete structures-Part 1-2: General rules-Structural fire design, Brussels, Belgium (2004)
32. Huismann S (2010) Materialverhalten von hochfestem Beton unter thermomechanischer Beanspruchung. Dissertation, Technische Universität Wien, Vienna Austria
33. McNamee R, Sjöström J, Biström L (2021) Reduction of fire spalling of concrete with small doses of polypropylene fibres. Fire Mater 2021:1–9. https://doi.org/10.1002/fam.300510.1002/fam.3005 ↗
34. Mindeguia J-C, Pimienta P, Carré H, La Borderie C (2013) Experimental analysis of concrete spalling due to fire exposure. Eur J Environ Civ Eng 6:453–46610.1080/19648189.2013.786245 ↗