Screw connectors for thin topping, timber–concrete composites
Source abstract
Abstract
Timber floors with insufficient strength and stiffness can be upgraded by applying a concrete topping to form a composite structure. Conventional upgrades have a topping thickness of 40 mm or greater but recent research has proposed an alternative thin topping solution (20 mm). The shear connectors which transfer the forces between the timber joists and concrete topping are critical to the success of the upgrade. This paper presents the results of pushout testing of thin topping timber–concrete composite joints. A factorial experimental design was employed to assess how the inclination, topping thickness and timber density affect the stiffness and strength of screw joints. The results were statistically assessed to differentiate between the effects of each factor and establish the presence of interactions between factors. The screw inclination and topping thickness were found to be important factors when considering the stiffness of the joints. Topping thickness was the most critical factor for the strength of the joints.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Tree Root and Stability Studies · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Ceccotti A (2002) Composite concrete-timber structures. Prog Struct Eng Mater 4(3):264–27510.1002/pse.126 ↗
2. Fragiacomo M (2012) Experimental behaviour of a full-scale timber-concrete composite floor with mechanical connectors. Mater Struct 5(11):1717–173510.1617/s11527-012-9869-3 ↗
3. Clouston P, Civjan S, Bathon L (2004) Experimental behavior of a continuous metal connector for a wood-concrete composite system. For Prod J 54(6):76–84
4. Deam BL, Fragiacomo M, Buchanan AH (2007) Connections for composite concrete slab and LVL flooring systems. Mater Struct 41(3):495–50710.1617/s11527-007-9261-x ↗
5. Dias AMPG, Lopes SMR, van de Kuilen JW, Cruz HMP (2007) Load-carrying capacity of timber-concrete joints with dowel-type fasteners. J Struct Eng 133(5):720–72710.1061/(ASCE)0733-9445(2007)133:5(720) ↗
6. Fragiacomo M, Amadio C, Macorini L (2006) Short and long-term performance of the “Tecnaria” stud connector for timber-concrete composite beams. Mater Struct 40(10):1013–102610.1617/s11527-006-9200-2 ↗
7. Frangi A, Fontana M (2003) Elasto-plastic model for timber-concrete composite beams with ductile connection. Struct Eng Int 13(1):47–5710.2749/101686603777964856 ↗
8. Lukaszewska E, Johnsson H, Fragiacomo M (2008) Performance of connections for prefabricated timber-concrete composite floors. Mater Struct 41(9):1533–155010.1617/s11527-007-9346-6 ↗
9. van der Linden M (1999) Timber–concrete composite floor systems. Ph.D. thesis, Delft University
10. Yeoh D, Fragiacomo M, De Franceschi M, Buchanan AH (2011) Experimental tests of notched and plate connectors for LVL–concrete composite beams. J Struct Eng 137(2):261–26910.1061/(ASCE)ST.1943-541X.0000288 ↗
11. Skinner J, Harris R, Paine K, Walker P, Bregulla J (2012) The characterisation of connectors for the upgrade of timber floors with thin structural toppings. In: Proceedings of 12th world conference on timber engineering, Auckland, New Zealand
12. Ahmadi BH, Saka MP (1993) Behaviour of composite timber-concrete floors. J Struct Eng 119(11):3111–313010.1061/(ASCE)0733-9445(1993)119:11(3111) ↗
13. Dias AMPG, Cruz HMP, Lopes SMR, van de Kuilen JW (2010) Stiffness of dowel-type fasteners in timber–concrete joints. Proc ICE Struct Build 163(4):257–26610.1680/stbu.2010.163.4.257 ↗
14. Jorge LFC, Lopes SMR, Cruz HMP (2011) Interlayer influence on timber-LWAC composite structures with screw connections. J Struct Eng 137(5):618–62410.1061/(ASCE)ST.1943-541X.0000299 ↗
15. Steinberg E, Selle R, Faust T (2003) Connectors for timber-lightweight concrete composite structures. J Struct Eng 129(11):1538–154510.1061/(ASCE)0733-9445(2003)129:11(1538) ↗
16. Persaud R, Symons D, Stanislaus H (2010) Slip modulus of inclined screws in timber-concrete floors. Proc ICE Struct Build 163(4):245–25510.1680/stbu.2010.163.4.245 ↗
17. Neve O (2009) Shear connectors for thin topping timber-concrete composite floors. Struct Eng 87(17):21–23
18. Cohen J (1992) A power primer. Psychol Bull 112(1):155–15910.1037/0033-2909.112.1.155 ↗
19. Dias AMPG (2005) Mechanical behaviour of timber-concrete joints. Ph.D. thesis, University of Coimbra
20. Faul F, Erdfelder E, Buchner A, Lang AG (2009) Statistical power analyses using g* power 3.1: tests for correlation and regression analyses. Behav Res Methods 41(4):1149–116010.3758/BRM.41.4.1149 ↗
21. Comité Européen de Normalisation (1991) Timber structures—joints made with mechanical fasteners—general principles for the determination of strength and deformation characteristics. EN 26891. Brussels, Belgium
22. Comité Européen de Normalisation (2004) Eurocode 2-design of concrete structures-part1-1: general rules and rules for buildings. EN 1992-1-1, Brussels, Belgium
23. Montgomery DC (2004) Design and analysis of experiments, 6th edn. Wiley, New York
24. Wobbrock JO, Findlater L, Gergle D, Higgins J (2011) The aligned rank transform for nonparametric factorial analyses using only ANOVA procedures. In: Proceedings of 2011 annual conference on human factors in computing systems. ACM Press, New York10.1145/1978942.1978963 ↗
25. Comité Européen de Normalisation (2004) Eurocode 5-design of timber structures-part1-1: general rules and rules for buildings. EN 1995-1-1, Brussels, Belgium