journal article·2008Open access

Short-term effects of oral appliances with equal bite-raising distance but with varying protrusions on occlusal force, contact area and load center

Kuniko Saito, Takayuki Ikeda, Nobuhito Gionhaku, Toshimitsu Iinuma, Jin Sato, Jun Lee

Journal of Oral Science· Volume 50· Issue 3

Abstract

The purpose of this study was to demonstrate how short-term wearing of an oral appliance (OA) with equal bite-raising distance but with varying protrusions affects occlusal force, contact area and load center. Twelve young healthy volunteers participated. With the appliance, the mandible was protruded 0%, 45%, 60% and 75% of maximum protrusion capacity, with 10 mm bite-raising between the first molars. The occlusal force, contact area and load center at maximum voluntary clenching were measured before wearing the OA, at 1 h, 3 h and 6 h during wearing, and 1 h after removal. When compared to the values before wearing the OA, occlusal force was significantly lower at 1 h, 3 h and 6 h during wearing in the case of no mandibular protrusion, and at 3 h and 6 h after for 45%, 60% and 75% of maximum mandibular protrusion (P < 0.05). Occlusal contact area was significantly smaller at 1 h and 6 h during wearing in the case of no protrusion, and at 6 h during wearing in the case of 45% of maximum protrusion (P < 0.05). There was a tendency for anterior shift in the location of the occlusal load center at 3 h and 6 h during wearing of the OA with any level of maximum protrusion. No significant change in these three measurements was found at 1 h after removal of the OA. The present study demonstrated that wearing an OA had only a marginal and transient influence on oral functions when their changes were compared before and after wearing the OA.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Temporomandibular Joint Disorders · Obstructive Sleep Apnea Research · Orthodontics and Dentofacial Orthopedics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. 1. Lindman R, Bondemark L (2001) A review of oral devices in the treatment of habitual snoring and obstructive sleep apnea. Swed Dent J 25, 39-51
2. 2. Liu Y, Zeng X, Fu M, Huang X, Lowe AA (2000) Effects of a mandibular repositioner on obstructive sleep apnea. Am J Orthod Dentofacial Orthop 118, 248-25610.1067/mod.2000.104831 ↗
3. 3. Tegelberg A, Wilhelmsson B, Walker-Engström ML, Ringqvist M, Andersson L, Krekmanov L, Ringqvist I (1999) Effects and adverse events of a dental appliance for treatment of obstructive sleep apnoea. Swed Dent J 23, 117-126
4. 4. Bondemark L (1999) Does 2 years' nocturnal treatment with a mandibular advancement splint in adult patients with snoring and OSAS cause a change in the posture of the mandible? Am J Orthod Dentofacial Orthop 116, 621-62810.1016/S0889-5406(99)70196-4 ↗
5. 5. O'Sullivan RA, Hillman DR, Mateljan R, Pantin C, Finucane KE (1995) Mandibular advancement splint: an appliance to treat snoring and obstructive sleep apnea. Am J Respir Crit Care Med 151, 194-19810.1164/ajrccm.151.1.7812552 ↗
6. 6. Rose EC, Schnegelsberg C, Staats R, Jonas IE (2001) Occlusal side effects caused by a mandibular advancement appliance in patients with obstructive sleep apnea. Angle Orthod 71, 452-460
7. 7. Pantin CC, Hillman DR, Tennant M (1999) Dental side effects of an oral device to treat snoring and obstructive sleep apnea. Sleep 22, 237-24010.1093/sleep/22.2.237 ↗
8. 8. Rose E, Staats R, Virchow C, Jonas IE (2002) A comparative study of two mandibular advancement appliances for the treatment of obstructive sleep apnoea. Eur J Orthod 24, 191-19810.1093/ejo/24.2.191 ↗
9. 9. Ringqvist M, Walker-Engström M-L, Tegelberg Å, Ringqvist I (2003) Dental and skeletal changes after 4 years of obstructive sleep apnea treatment with a mandibular advancement device: a prospective, randomized study. Am J Orthod Dentofacial Orthop 124, 53-6010.1016/S0889-5406(03)00240-3 ↗
10. 10. Marklund M, Franklin KA, Persson M (2001) Orthodontic side-effects of mandibular advancement devices during treatment of snoring and sleep apnoea. Eur J Orthod 23, 135-14410.1093/ejo/23.2.135 ↗
11. 11. Pitsis AJ, Darendeliler MA, Gotsopoulos H, Petocz P, Cistulli PA (2002) Effect of vertical dimension on efficacy of oral appliance therapy in obstructive sleep apnea. Am J Respir Crit Care Med 166, 860-86410.1164/rccm.200204-342OC ↗
12. 12. Walker-Engström ML, Ringqvist I, Vestling O, Wilhelmsson B, Tegelberg A (2003) A prospective randomized study comparing two different degrees of mandibular advancement with a dental appliance in treatment of severe obstructive sleep apnea. Sleep Breath 7, 119-13010.1007/s11325-003-0119-3 ↗
13. 13. Sinogaya T, Matsumoto M (1998) Evaluation of prosthodontic treatment by occlusal force distribution: a methodological study. Eur J Prosthodont Restor Dent 6, 121-125
14. 14. Taga H, Tomaru T, Naitoh S, Maehara S, Taga M, Maehara K, Serada K (2004) Effect of template therapy on sleep apnea syndrome. Showa Igakkai Zasshi 64, 114-119 (in Japanese)
15. 15. Hattori Y, Okugawa H, Watanabe M (1994) Occlusal force measurement using dental prescale. Nihon Hotetsu Shikagakkai Zasshi 38, 835-841 (in Japanese)10.2186/jjps.38.835 ↗
16. 16. Shiono H, Chiba SH, Watanabe S, Igarashi T, Nakajima K, Takeda T, Ishigami K, Ohki K (1995) Basic study on “Dental Prescale System” Part I. The range of fluctuation in occlusal contact area and the influence of applying bite-silicone material on “Dental Prescale”. Nihon Hotetsu Shikagakkai Zasshi 39, 710-716 (in Japanese)10.2186/jjps.39.710 ↗
17. 17. Ulrich J (1959) The human temporomandibular joint: kinematics and actions of the masticatory muscles. J Prosthet Dent 9, 399-40810.1016/0022-3913(59)90070-8 ↗
18. 18. Kawamura Y, Abe K (1974) Role of sensory information from temporomandibular joint. Bull Tokyo Med Dent Univ 21 Suppl, 78-82
19. 19. Bondemark L, Lindman R (2000) Craniomandibular status and function in patients with habitual snoring and obstructive sleep apnoea after nocturnal treatment with a mandibular advancement splint: a 2-year follow-up. Eur J Orthod 22, 53-6010.1093/ejo/22.1.53 ↗