journal article·2015-01

The effects of pulse electrodeposition parameters on morphology and formation of dual-layer Si-doped calcium phosphate coating on AZ31 alloy

Peng Wan, Xun Qiu, LiLi Tan, XinMin Fan, Ke Yang

Ceramics International· Volume 41· Issue 1
Publisher page

Abstract

Controlling the corrosion rate of magnesium alloys in vivo to match the bone repair is crucially important for application as biodegradable orthopedic implants. To solve this challenge, a Si-doped Ca-P coating with a novel dual-layer structure was deposited on AZ31 alloy substrate by pulse electrodeposition. The morphology, composition and formation of dual-layer coating were believed to be determined by pulse electrodeposition parameters, thus the deposition time, temperature, duty cycle, pH value of the electrolyte and the standing duration of mixed electrolyte were regulated to seek possible influences and mechanism on the coating formation. Weight gain and pH monitoring tests were also used to evaluate the performance of coating under the varied parameters. The results indicated that deposition temperature and time remarkably influenced the morphology, homogeneity and crystallinity of Ca-P coating. A uniform and compact coating with better degradation performance was obtained at 60 degrees C with deposition time of 40 min. The shorter standing duration of the electrolyte lead to an incomplete coating and uneven distribution of Si contents. The two coupled deposition models contributed to this dual-layer structure of Si-doped Ca-P coating and possible formation mechanism was proposed. (C) 2014 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Aluminum Alloys Composites Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. The history of biodegradable magnesium implants: a review10.1016/j.actbio.2010.02.028 ↗
2. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
3. Cartilage repair on magnesium scaffolds used as a subchondral bone replacement10.1002/mawe.200600027 ↗
4. Control of biodegradation of biocompatible magnesium alloys10.1016/j.corsci.2007.01.001 ↗
5. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
6. An in vitro evaluation of the Ca/P ratio for the cytocompatibility of nano-to-micron particulate calcium phosphates for bone regeneration10.1016/j.actbio.2008.02.025 ↗
7. Magnesium alloys as promising degradable implant materials in orthopedic research
8. Calcium phosphate coatings for bio-implant applications: materials, performance factors, and methodologies10.1016/j.mser.2009.05.001 ↗
9. Silicon: a requirement in bone formation independent of vitamin D110.1007/BF02409409 ↗
10. Silicon localization and calcification in developing bone
11. Silicon: a possible factor in bone calcification10.1126/science.167.3916.279 ↗
12. A relationship between silicon and calcium in bone formation
13. A comparative study on the in vivo behavior of hydroxyapatite and silicon substituted hydroxyapatite granules10.1023/A:1021114710076 ↗
14. Effect of sintered silicate –substituted hydroxyapatite on remodeling processes at the bone-implant interface10.1016/j.biomaterials.2003.10.006 ↗
15. Novel silicon-doped hydroxyapatite (Si-HA) for biomedical coatings: an in vitro study using acellular simulated body fluid10.1002/jbm.b.30368 ↗
16. Preparation and characterization of hydroxyapatite forsterite bioactive glass nanocomposite coatings for biomedical applications10.1016/j.ceramint.2011.09.008 ↗
17. Enhancing the performance of calcium phosphate coating on a magnesium alloy for bioimplant applications10.1016/j.matlet.2012.02.050 ↗
18. Effect of electrodeposition modes on surface characteristics and corrosion properties of fluorine-doped hydroxyapatite coatings on Mg–Zn–Ca alloy10.1016/j.apsusc.2010.12.073 ↗
19. Thin calcium phosphate coatings on titanium by electrochemical deposition in modified simulated body fluid10.1002/jbm.a.30514 ↗
20. In vitro degradation and mechanical integrity of Mg–Zn–Ca alloy coated with Ca-deficient hydroxyapatite by the pulse electrodeposition process10.1016/j.actbio.2009.12.009 ↗
21. Preliminary research of a novel bioactive silicon doped calcium phosphate coating on AZ31 magnesium alloy via electrodeposition10.1016/j.msec.2013.11.041 ↗
22. Preparation of calcium phosphate coatings on Mg–1.0Ca alloy10.1016/S1003-6326(09)60194-1 ↗
23. Electrodeposition of hydroxyapatite coating on CoNiCrMo substrate in dilute solution10.1016/j.surfcoat.2010.03.020 ↗
24. Electrodeposition of Ca–P coatings on biodegradable Mg alloy: in vitro biomineralization behavior10.1016/j.actbio.2009.12.020 ↗
25. An electrodeposition method of calcium phosphate coatings on titanium alloy10.1007/s10856-006-0703-8 ↗
26. Calcium phosphate coatings on magnesium alloys for biomedical applications: a review10.1016/j.actbio.2011.10.016 ↗
27. Preparation of calcium phosphate coating on pure titanium substrate by electrodeposition method10.1007/s11771-004-0030-5 ↗
28. In vivo requirement for silicon in articular cartilage and connective tissue formation in the chick10.1093/jn/106.4.478 ↗
29. W. Cui, E. Beniash, E. Gawalt, et al. Biomimetic coating of magnesium alloy for enhanced corrosion resistance and calcium phosphate deposition. Acta Biomater., doi: 10.1016/j.actbio.2013.06.031.10.1016/j.actbio.2013.06.031 ↗