journal article·2014-11

Synthesis and biodegradation evaluation of nano-Si and nano-Si/TiO2 coatings on biodegradable Mg–Ca alloy in simulated body fluid

H.R. Bakhsheshi-Rad, E. Hamzah, M. Daroonparvar, M. Kasiri-Asgarani, M. Medraj

Ceramics International· Volume 40· Issue 9
Publisher page

Abstract

Abstract In the present study, nano-Si and nano-Si/TiO 2 composite coatings have been successfully synthesized on the surface of Mg–1 wt%Ca alloy by the physical vapor deposition (PVD) method. The surface morphology and compositions of the coated specimens were characterized by X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The results show the formation of thin and compact coating layers which homogeneously cover the surface of Mg alloy. Some micro-pores and micro-cracks were observed in the Si and Si/TiO 2 films. It was also found that the Si and TiO 2 nanoparticle had a spherical morphology with an average particle size of 30–40 nm and 70–80 nm, respectively. Electrochemical studies revealed that nano-Si/TiO 2 coating offers a significant reduction in the corrosion rate (0.57 mm/year) compared to the Si coated (0.91 mm/year) and the uncoated alloys (6.21 mm/year) in simulated body fluid (SBF). Hydrogen evolution studies showed a lower degradation rate of nano-Si/TiO 2 (1.57 ml/cm 2 /day) than that of nano-Si coated alloy (2.22 ml/cm 2 /day). Immersion test showed that the nano-Si/TiO 2 coating presented a greater nucleation site of hydroxyapatite (HA) than the uncoated sample. Thus nano-Si/TiO 2 composite coating prepared by PVD on the Mg–Ca alloy is more appropriate for biomedical applications.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Effects of silicon plasma ion implantation on electrochemical corrosion behavior of biodegradable Mg–Y–RE Alloy10.1016/j.corsci.2012.11.037 ↗
2. Bioactive HA/TiO2 coating on magnesium alloy for biomedical applications10.1016/j.ceramint.2013.11.119 ↗
3. Plasma enhanced chemical vapor deposited silicon coatings on Mg alloy for biomedical application10.1016/j.surfcoat.2012.05.128 ↗
4. Controlling the degradation rate of bioactive magnesium implants by electrophoretic deposition of akermanite coating10.1016/j.ceramint.2013.08.027 ↗
5. Enhanced biocorrosion resistance of surface modified magnesium alloys using inorganic/organic composite layer for biomedical applications10.1016/j.ceramint.2013.07.142 ↗
6. Electrophoretic deposition of bioactive glass nanopowders on magnesium based alloy for biomedical applications10.1016/j.ceramint.2013.12.135 ↗
7. In-vitro corrosion inhibition mechanism of fluorine-doped hydroxyapatite and brushite coated Mg–Ca alloys for biomedical applications10.1016/j.ceramint.2013.12.147 ↗
8. Preparation and characterization of ceramic/metal duplex coatings deposited on AZ31 magnesium alloy by multi-magnetron sputtering10.1016/j.matlet.2005.09.066 ↗
9. Corrosion behaviour of magnesium alloys coated with TiN by cathodic arc deposition in NaCl and Na2SO4 solutions10.1016/j.matchar.2007.01.004 ↗
10. Corrosion behavior of Ti–Al–N/Ti–Al duplex coating on AZ31 magnesium alloy in NaCl aqueous solution10.1016/j.matchar.2009.01.009 ↗
11. Surface characteristics and corrosion behaviour of WE43 magnesium alloy coated by SiC film10.1016/j.apsusc.2011.11.040 ↗
12. Corrosion behavior in SBF for titania coatings on Mg–Ca alloy10.1007/s10853-010-5083-2 ↗
13. Microstructure and corrosion behavior of micro-arc oxidation coating on 6061 aluminum alloy pre-treated by high-temperature oxidation10.1016/j.apsusc.2013.09.178 ↗
14. Microstructure analysis and corrosion behavior of biodegradable Mg–Ca implant alloys10.1016/j.matdes.2011.06.057 ↗
15. The preparation and characteristics of a rare earth/nano-TiO2 composite coating on aluminum alloy by brush plating10.1016/j.surfcoat.2012.01.027 ↗
16. Influence of albumin and inorganic ions on electrochemical corrosion behavior of plasma electrolytic oxidation coated magnesium for surgical implants10.1016/j.apsusc.2013.05.100 ↗
17. Mechanical and in vitro degradation behavior of ultrafine calcium polyphosphate reinforced magnesium-alloy composites10.1016/j.matdes.2010.12.054 ↗
18. Effect of electrodeposition modes on surface characteristics and corrosion properties of fluorine-doped hydroxyapatite coatings on Mg–Zn–Ca alloy10.1016/j.apsusc.2010.12.073 ↗
19. Microwave-processed nanocrystalline hydroxyapatite: simultaneous enhancement of mechanical and biological properties10.1016/j.actbio.2010.03.016 ↗
20. Comparison of calcium phosphate coatings on Mg–Al and Mg–Ca alloys and their corrosion behavior in Hank׳s solution10.1016/j.surfcoat.2010.04.038 ↗
21. Synthesis and in vitro degradation evaluation of the nano-HA/MgF2 and DCPD/MgF2 composite coating on biodegradable Mg–Ca–Zn alloy10.1016/j.surfcoat.2013.02.007 ↗
22. Measurement of the corrosion rate of magnesium alloys using Tafel extrapolation10.1016/j.corsci.2009.10.016 ↗
23. Novel bioactive materials with different mechanical properties10.1016/S0142-9612(03)00044-9 ↗