journal article·2019-03

Effect of transition layer on the performance of hydroxyapatite/titanium nitride coating developed on Ti-6Al-4V alloy by magnetron sputtering

Jianwei Qi, Yiming Yang, Mingming Zhou, Zhangbo Chen, Kai Chen

Ceramics International· Volume 45· Issue 4
Publisher page

Abstract

Abstract A gradient transition multilayer hydroxyapatite/titanium nitride (HA/TiN) coating was prepared on the Ti-6Al-4V alloy by magnetron sputtering. The composition, surface topography, microstructure, adhesion strength and electrochemical properties of the as-deposited coatings were characterized by SEM/EDS, AFM, XRD, FT-IR and electrochemical workstation. The experimental results showed that the single TiN coating deposited at a partial pressure of nitrogen (N2) of 0.08 Pa had the best internal stress and tribological performance, and its volume loss was only 0.89% of that of Ti-6Al-4V alloy. The introduction of the TiN transition layer greatly improved the wear resistance of the Ti-6Al-4V alloy, and the adhesion strength of the HA layer to the substrate increased from 6.50 ± 0.5 N to 11.70 ± 1.2 N, an increase of 56%. The HA/TiN coating surface consisted of uniform hemispherical particles with dense structure and invisible defects (micro-cracks and pores). For the HA surface layer, the crystal structure and active hydroxyl (-OH) group was restored after heat treatment. Potentiodynamic polarization experiments indicated that the HA/TiN coating achieved the lowest corrosion current density and the most positive corrosion potential compared to the single TiN layer and Ti-6Al-4V alloy. In summary, it can be conclude that the gradient transition layer can well improve the mechanical properties and electrochemical behavior of the titanium alloy, and largely ensuring the stability of the surface bioactive coating.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Fretting fatigue behavior of surface modified biomedical titanium alloys10.1007/s12666-010-0030-0 ↗
2. Titanium alloys in total joint replacement-a materials science perspective
3. Hip implants-Paper VI-Ion concentrations10.1016/j.matdes.2005.05.018 ↗
4. Microstructure, and mechanical properties of tip/Al composite10.1002/adem.200300378 ↗
5. Pulsed laser deposition of hydroxyapatite thin films10.1016/j.msec.2006.05.025 ↗
6. Microstructure and mechanical properties of hydroxyapatite thin films grown by RF magnetron sputtering10.1016/S0257-8972(03)00729-1 ↗
7. Cast titanium as implant material10.1007/BF00123367 ↗
8. Porous coated versus grit blasted surface texture of hydroxyapatite coated implants during controlled micromotion10.1016/S0883-5403(98)90011-0 ↗
9. Deposition of titanium nitride and hydroxyapatite-based biocompatible composite by reactive plasma spraying10.1016/j.apsusc.2011.12.049 ↗
10. Correlative experimental animal and human clinical retrieval evaluations of hydroxyapatite (HA)-coated and non-coated implants in orthopaedics and dentistry10.1615/CritRevBiomedEng.v28.i34.80 ↗
11. Assessment of bioactivity for orthopedic coatings in a gap-healing model10.1002/(SICI)1097-4636(199708)36:2<265::AID-JBM16>3.0.CO;2-F ↗
12. Comparative investigation on the adhesion of hydroxyapatite coating on Ti–6Al–4V implant: a review paper10.1016/j.ijadhadh.2013.09.030 ↗
13. Comparative investigation on the adhesion of hydroxyapatite coating on Ti-6Al-4V implant: a review paper10.1016/j.ijadhadh.2013.09.030 ↗
14. Wear behavior of PVD TiN coated carbide inserts during machining of Nimonic 90 and Ti6Al4V superalloys under dry and MQL conditions10.1016/j.ceramint.2016.06.124 ↗
15. In vitro assessments on bacterial adhesion and corrosion performance of TiN coating on Ti6Al4V titanium alloy synthesized by multi-arc ion plating10.1016/j.apsusc.2012.03.163 ↗
16. Biaxial residual states of plasma-sprayed hydroxyapatite coatings on titanium alloy substrate10.1016/S0142-9612(99)00272-0 ↗
17. The thermal lattice expansion of calcium hydroxyapatite10.1016/0022-0248(87)90534-3 ↗
18. Pierson · 1997
19. Sliding wear studies of selected nitride coatings and their potential for long-term use in orthopaedic applications, Proceedings of the Institution of mechanical Engineers
20. Bonding strength investigation of plasma-sprayed HA coatings on alumina substrate with porcelain intermediate layer10.1016/j.matchemphys.2007.03.021 ↗
21. Biomedical surface science: foundations to frontiers10.1016/S0039-6028(01)01587-4 ↗
22. Phase composition of sputtered films from a hydroxyapatite target10.1016/S0257-8972(02)00363-8 ↗
23. Influence of annealing temperature on RF-magnetron sputtered calcium phosphate coatings10.1016/0142-9612(96)89656-6 ↗
24. Crystal chemistry of hydroxyapatite deposited on titanium by sputtering technique
25. Effect of atmosphere on phase transformation in plasma-sprayed hydroxyapatite coatings during heat treatment10.1002/(SICI)1097-4636(199701)34:1<15::AID-JBM3>3.0.CO;2-Q ↗
26. Pulsed laser deposition of hydroxyapatite thin films on Ti-5Al-2.5Fe substrates with and without buffer layers10.1016/S0169-4332(00)00616-4 ↗
27. The preparation of calcium phosphate coatings on titanium and nickel–titanium by rf-magnetron-sputtered deposition: composition, structure andmicromechanical properties10.1016/j.surfcoat.2008.01.038 ↗
28. The role of macrophages in osteolysis of total joint replacement10.1016/j.biomaterials.2004.04.035 ↗
29. The osteoclastogenic molecules RANKL and RANK are associated with periprosthetic osteolysis10.1302/0301-620X.83B6.10905 ↗
30. The potential role of human osteoblasts for periprosthetic osteolysis following exposure to wear particles
31. Toll like receptors in the interface membrane around loosening total hip replacement implants10.1002/jbm.a.31235 ↗
32. Human rheumatoid synovial fibroblasts promote osteoclastogenic activity by activating RANKL via TLR-2 and TLR-4 activation10.1016/j.imlet.2007.03.004 ↗
33. Surface characterization and mechanical property of TiN Ti-coated NiTi alloy by PIIID10.1016/j.surfcoat.2006.09.055 ↗
34. TiN coating improves the corrosion behavior of superelastic NiTi surgical alloy10.1016/S0257-8972(01)01356-1 ↗
35. A study on the hot corrosion behavior of Ti–6Al–4V alloy10.1016/j.matlet.2006.07.058 ↗