Corrosion behavior of electrochemically assembled nanoporous titania for biomedical applications

K. Indira, U. Kamachi Mudali, N. Rajendran

Ceramics International· Volume 39· Issue 2
Publisher page

Abstract

Abstract Corrosion resistance of nanoporous titania was investigated in Hank’s solution using potentiodynamic polarization and electrochemical impedance spectroscopic techniques. The phase structure, surface morphology and elemental composition of the untreated, anodized heat treated and anodized heat treated titanium specimens immersed in Hank’s solution for seven days were characterized using X-ray diffraction, atomic force microscopy and scanning electron microscopy with energy dispersive X-ray spectroscopy techniques, respectively. The X-ray diffraction technique revealed that the anodized heat treated titanium exhibited anatase structure. The atomic force microscopic and scanning electron microscopic results showed that the titanium surface has transformed from a smooth to nanoporous surface depending on the anodization conditions. The energy dispersive X-ray spectroscopy results confirmed the formation of hydroxyapatite over the anodized titanium after immersion for seven days in Hank’s solution. The electrochemical results revealed that the anodized heat treated titanium after seven day immersion in Hank’s solution showed nobler shift in corrosion potential compared to untreated and anodized titanium. Hence, the results suggested that the nanoporous titania layer developed on titanium is a promising material for application as orthopaedic implants.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Corrosion of bioimplants10.1007/BF02706450 ↗
2. Surface characterization of passive film formed on nitrogen ion implanted Ti–6Al–4V and Ti–6Al–7Nb alloys using10.1016/S0010-938X(03)00027-1 ↗
3. Nitrogen ion implantation and in vitro corrosion behavior of as-cast Ti–6Al–7Nb alloy10.1016/S0010-938X(02)00034-3 ↗
4. Influence of microstructure and alloying elements on corrosion behavior of Ti–13Nb–13Zr alloy10.1016/S0010-938X(03)00186-0 ↗
5. Review of titania nanotubes: fabrication and cellular response10.1016/j.ceramint.2012.03.002 ↗
6. Fabrication of corrosion resistance, bioactive and antibacterial silver substituted hydroxyapatite/titania composite coating on Cp Ti10.1016/j.ceramint.2011.07.065 ↗
7. Surface characterization of titanium anodized in the four different types of electrolyte10.1016/j.electacta.2007.07.067 ↗
8. Hydroxyapatite formation on oxide films containg Ca and P by hydrothermal treatment10.1016/j.ceramint.2005.04.006 ↗
9. Self-ordering electrochemistry: a review on growth and functionality of TiO2 nanotubes and other self aligned MOx structures10.1039/b822726h ↗
10. G. Wu, J. Zhang, X. Wang, J. Liao, H. Xia, S.A. Akbar, J. Li, S. Lin, X. Li, J. Wang, Hierarchical nanostructured TiO2 nano-tubes for formaldehyde sensing, Ceramics International, (2012) 〈http://dx.doi.org/10.1016/j.ceramint.2012.05.004〉.10.1016/j.ceramint.2012.05.004 ↗
11. Corrosion resistance evaluation of porous titanium with biomimetic coatings10.4028/www.scientific.net/MSF.591-593.55 ↗
12. Microstructure and deformation behavior of biocompatible TiO2 nanotubes on titanium substrate10.1016/j.actbio.2006.08.004 ↗
13. Preparation and characterization of electrophoretically deposited hydroxyapatite coating on type 316L stainless steel10.1016/S0010-938X(02)00091-4 ↗
14. Behavior of anodic layer in Ringer’s solution on Ti–6Al–4V ELI alloy after bending
15. Electrochemical behavior of titanium and titanium alloy in artificial saliva
16. Corrosion inhibition of titanium in acidic media containing fluoride with bixin10.1155/2009/307034 ↗
17. Corrosion behavior of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in simulated body fluid solution electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
18. Electrochemical studies on the stability and corrosion resistance of titanium based implant materials10.1016/S0142-9612(00)00309-4 ↗
19. Insitu characterization of passive film on Al–Ti alloy by photocurrent and impedance spectroscopy10.1016/S0010-938X(98)00009-2 ↗
20. Characterization hafnium anodic oxide films: an AC impedance investigation10.1016/0013-4686(95)00003-W ↗
21. Electrochemical impedance spectroscopy study of the nucleation and growth of apatite on chemically treated pure titanium10.1016/S0167-577X(01)00532-8 ↗
22. Bioactive and electrochemical characterization of TiO2 nanotubes on titanium via anodic oxidation10.1016/j.electacta.2010.05.082 ↗
23. Electrochemical and electrophoretic deposition of hydroxyapatite for orthopaedic applications10.1179/174329405X50091 ↗
24. Influence of titania nanotube arrays on biomimetic deposition apatite on titanium by alkali treatment10.1016/j.matchemphys.2007.05.014 ↗
25. Evaluation of corrosion behavior of surface modified Ti–6Al–4V ELI alloy in Hanks solution10.1007/s10800-009-9972-5 ↗
26. Surface treatments of titanium dental implants for osseointegration10.1016/j.dental.2006.06.025 ↗
27. Characterisation and corrosion resistance of the electrodeposited hydroxyapatite and bovine serum albumin/hydroxyapatite films on Ti–6Al–4V–1Zr alloy surface10.1016/j.corsci.2010.11.033 ↗
28. K.S. Brammer, S. Oh, C.J. Frandsen, S. Jin, Biomaterials and biotechnology schemes utilizing TiO2 nanotube arrays, Biomaterials Science and Engineering ISBN 978-953-307-609-6.
29. Fan · Chinese Journal of Chemical Physics · 2007 · 20 · 75310.1088/1674-0068/20/06/753-758 ↗
30. Formation behavior of anodic TiO2 nanotubes in fluoride containing electrolytes10.1016/S1003-6326(08)60361-1 ↗
31. Electrochemical corrosion behavior of magnesium and titanium alloys in simulated body fluid10.1016/j.electacta.2009.07.047 ↗
32. Electrochemical and biological behaviors of porous titania (TiO2) in simulated body fluids for implantation in human bodies10.1016/j.jallcom.2008.08.061 ↗
33. Wettability changes of TiO2 nanotube surfaces10.1088/0957-4484/22/31/315704 ↗
34. Corrosion resistance of the surface layers formed on titanium by plasma electrolytic oxidation and hydrothermal treatment10.1016/j.vacuum.2005.01.017 ↗
35. An electrochemical study of self-ordered nanoporous and nanotubular oxide on Ti–35Nb–5Ta–7Zr alloy for biomedical applications10.1016/j.actbio.2009.02.017 ↗
36. EIS characterization of Ti anodic oxide porous films formed using modulated potential10.1016/j.surfcoat.2007.03.005 ↗
37. Effect of electrolyte concentration on morphology, microstructure and electrochemical impedance of anodic oxide film on titanium alloy Ti–10V–2Fe–3Al10.1007/s10800-010-0132-8 ↗
38. In vitro corrosion behavior of Ti–5Al–2Nb–1Ta alloy in Hanks solution10.1002/maco.200604001 ↗
39. The biocompatibility of HA thin films deposition on anodized titanium alloys10.1016/j.surfcoat.2010.08.015 ↗