journal article·2013-01

Fabrication and characterization of micro-arc oxidized fluoride containing titania films on Cp Ti

K. Venkateswarlu, N. Rameshbabu, D. Sreekanth, A.C. Bose, V. Muthupandi, S. Subramanian

Ceramics International· Volume 39· Issue 1
Publisher page

Abstract

The present study is focussed at establishing an appropriate electrolyte system for developing electrochemically stable and fluorine (F) containing titania (F-TiO2) films on Cp Ti by micro-arc oxidation (MAO) technique. To fabricate the F-TiO2 films on Cp Ti, different electrolyte solutions of chosen concentrations of tri-sodium orthophosphate (TSOP, Na3PO4 center dot I2H2O), potassium hydroxide (KOH) and various F-containing compounds such as ammonium fluoride (NH4F), potassium fluoride (KF), sodium fluoride (NaF) and potassium fluorotitanate (K2TiF6) are employed. The structural and morphological characteristics, thickness and elemental composition of the developed films have been assessed by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) techniques. The in-vitro electrochemical corrosion behavior of the films was studied under Kokubo simulated body fluid (SBF) environment by potentiodynamic polarization, long term potential measurement and electrochemical impedance spectroscopy (EIS) methods. The XRD and SEM-EDS results show that the rutile content in the films vary in the range of 15-37 wt% and the F and P contents in the films is found to be in the range of 2-3 at% and 2.9-4.7 at% respectively, suggesting that the anatase to rutile phase transformation and the incorporation of F and P into the films are significantly controlled by the respective electrolyte solution. The SEM elemental mapping results show that the electrolyte borne F and P elements are incorporated and distributed uniformly in all the films. Among all the films under study, the film developed with 5 g TSOP+2 g KOH+3 g K2TiF6 electrolyte system exhibits considerably improved in-vitro corrosion resistance and therefore best suited for biomedical applications. (C) 2012 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Titania/hydroxyapatite bi-layer coating on Ti metal by electrophoretic deposition: characterization and corrosion studies10.1016/j.ceramint.2011.12.026 ↗
2. In vitro behavior of bacteria on fluoride ion-corted titanium: with special regands on porphyromonas gingivalis10.2485/jhtb.20.47 ↗
3. Effect of fluoride-ion implantation on the biocompatibility of titanium for dental applications10.1016/j.apsusc.2008.03.075 ↗
4. Fluoride modification effects on osteoblast behavior and bone formation at TiO2 grit-blasted c.p. titanium endosseous implants10.1016/j.biomaterials.2005.07.009 ↗
5. Titanium implant surface modification by cathodic reduction in hydrofluoric acid: surface characterization and in vivo performance10.1002/jbm.a.31898 ↗
6. Pre-treatment of titanium implants with fluoride improves their retention in bone10.1007/BF00134312 ↗
7. The role of fluoride ions on the corrosion of Ti36 in normal saline solution as applied to dental implant10.1016/S1452-3981(23)15332-6 ↗
8. Characterisation of oxide films produced by plasmaelectrolytic oxidation of a Ti–6Al–4V alloy10.1016/S0257-8972(00)00719-2 ↗
9. Influence of electrolyte chemistry on morphology and corrosion resistance of micro arc oxidation coatings deposited on magnesium10.1007/s11661-010-0412-2 ↗
10. The tribological performance of ultra-hard ceramic composite coatings obtained through microarc oxidation10.1016/S0257-8972(02)00646-1 ↗
11. The role of W doping in response of hydrogen sensors based on MAO films10.1016/j.apsusc.2010.01.015 ↗
12. Characterization and properties of microarc oxidized coatings containing Si, Ca and Na on titanium10.1016/j.ceramint.2011.03.006 ↗
13. Fabrication of corrosion resistant, bioactive and antibacterial silver substituted hydroxyapatite/titania composite coating on Cp Ti10.1016/j.ceramint.2011.07.065 ↗
14. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
15. Metals Test Methods and Analytical Procedures · 1987
16. Effect of various additives on morphology and corrosion behavior of ceramic coatings developed on AZ31 magnesium alloy by plasma electrolytic oxidation10.1016/j.ceramint.2012.02.040 ↗
17. Effects of NaAlO2 on structure and corrosion resistance of microarc oxidation coatings formed on AM60B magnesium alloy in phosphate–KOH electrolyte10.1016/j.surfcoat.2005.03.020 ↗
18. A theory of avalanche breakdown during anodic oxidation10.1016/0013-4686(87)85032-6 ↗
19. Microstructure characteristic of ceramic coatings fabricated on magnesium alloys by micro-arc oxidation in alkaline silicate solutions10.1016/j.apsusc.2005.09.067 ↗
20. Role of electrolyte additives on in-vitro electrochemical behaviour of micro arc oxidized titania films on Cp Ti10.1016/j.apsusc.2012.03.118 ↗
21. Mechanisms underlying the formation of thick alumina coatings through the MAO coating technology10.1016/S0257-8972(02)00918-0 ↗
22. The role of anions in the formation and corrosion resistance of the plasma electrolytic oxidation coatings10.1016/j.surfcoat.2009.09.069 ↗
23. Electrochemical study of growth behaviour of plasma electrolytic oxidation coating on Ti6Al4V: effects of the additive10.1016/j.corsci.2010.06.017 ↗
24. Synthesis and characterization of TiO2 nanoparticles10.1016/j.ceramint.2010.04.006 ↗
25. Dependence of growth features of microarc oxidation coatings of titanium alloy on control modes of alternate pulse10.1016/j.matlet.2003.11.026 ↗
26. In vitro studies of hydrogen peroxide treated titanium for biomedical applications10.1016/j.electacta.2009.11.057 ↗
27. In vitro corrosion and mineralization of novel Ti–Si–C alloy10.1016/j.electacta.2011.02.045 ↗
28. Study of the structure and corrosion behavior of PEO coatings on AM50 magnesium alloy by electrochemical impedance spectroscopy10.1016/j.surfcoat.2007.12.033 ↗