journal article·2018-08

Biological and corrosion behavior of m-ZrO2 and t-ZrO2 coated 316L SS for potential biomedical applications

Gobi Saravanan Kaliaraj, Vinita Vishwakarma, Karthik Alagarsamy, A.M. Kamalan Kirubaharan

Ceramics International· Volume 44· Issue 12
Publisher page

Abstract

Abstract Surface modification is an established technology in biomedical industries to improve the performance of implant materials. In the present study, monoclinic (m-ZrO2) and tetragonal (t-ZrO2) phases of zirconia were deposited on stainless steel (316L SS) by electron beam physical vapor deposition (EBPVD) to enhance several properties of substrate material. m-ZrO2 and t-ZrO2 coatings effectively protected bacterial invasion against pathogenic Pseudomonas aeruginosa (P. aeruginosa) and subsequent biofilm formation. Superior fibroblast cell viability with improved cells spreading was observed in m-ZrO2 and t-ZrO2 coatings. Furthermore, electrochemical impedance spectroscopy (EIS) results exhibited enhanced charge transfer resistance (Rct) and thus, strongly improved corrosion protection by m-ZrO2 and t-ZrO2 coatings compared to bare 316L SS substrate in artificial blood plasma (ABP).
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. AngioSeal device malfunction: a case report of dilator tip fracture and successful endovascular retrieval10.1016/j.ejvsextra.2011.06.010 ↗
2. Properties of implant alloys for artificial hip joints10.1007/BF02443329 ↗
3. Correlation between metal allergy and treatment outcomes after ankle fracture fixation10.1177/230949901101900309 ↗
4. Fluoroscopy-guided snare retrieval of the celt ACD metallic vascular closure device following failed deployment
5. Pediatric cardiovascular interventional devices: effect on CMR images at 1.5 and 3 T10.1186/1532-429X-15-54 ↗
6. Multifunctional zirconium nitride/copper multilayer coatings on medical grade 316L SS and titanium substrates for biomedical applications10.1016/j.jmbbm.2017.09.007 ↗
7. Inhibition of Pseudomonas aeruginosa PAO1 adhesion to and invasion of A549 lung epithelial cells by natural extracts
8. Environmental contamination with an epidemic strain of Pseudomonas aeruginosa in a Liverpool cystic fibrosis centre, and study of its survival on dry surfaces10.1016/j.jhin.2004.09.018 ↗
9. The effects on bone cells of metal ions released from orthopaedic implants, a review
10. Relating nickel-induced tissue inflammation to nickel release in vivo10.1002/jbm.1052 ↗
11. Mechanical properties, electrochemical corrosion and in-vitro bioactivity of yttria stabilized zirconia reinforced hydroxyapatite coatings prepared by gas tunnel type plasma spraying10.1016/j.jmbbm.2011.11.002 ↗
12. Fracture toughness of plasma-sprayed zirconia coatings10.1016/0257-8972(88)90084-9 ↗
13. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
14. A zirconia implant-crown system: a case report
15. In vitro evaluation of an yttria-stabilized zirconia reinforced nano-hydroxyapatite/polyamide 66 ternary biomaterial: biomechanics, biocompatibility and bioactivity10.1039/C6RA24509A ↗
16. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications10.1016/j.msec.2016.02.014 ↗
17. Corrosion and biocompatibility behaviour of zirconia coating by EBPVD for biomedical applications10.1016/j.surfcoat.2017.11.047 ↗
18. Biocompatible zirconia‐coated 316 stainless steel with anticorrosive behavior for biomedical application10.1016/j.ceramint.2018.02.213 ↗
19. Bioinert nano yttria stabilized zirconia coatings on 316L SS for dental applications
20. Biomechanical and histological behavior of zirconia implants: an experiment in the rat10.1111/j.1600-0501.2008.01656.x ↗
21. Corrosion, haemocompatibility and bacterial adhesion behaviour of TiZrN-coated 316L SS for bioimplants10.1007/s12034-015-0949-1 ↗
22. A comparative study of titanium nitride (TiN), titanium oxy nitride (TiON) and titanium aluminum nitride (TiAlN), as surface coatings for bio implants10.1016/j.surfcoat.2011.05.004 ↗
23. Influence of surface porosity and pH on bacterial adherence to hydroxyapatite and biphasic calcium phosphate bioceramics10.1099/jmm.0.002758-0 ↗
24. Charge transfer during staphylococcal adhesion to TiNOX coatings with different specific resistivity10.1016/S0301-4622(01)00177-6 ↗
25. Bacterial adhesion on biomedical surfaces covered by yttria stabilized zirconia
26. Studies of calcium precipitating oral bacterial adhesion on TiN, TiO2 single layer, and TiN/TiO2 multilayer – coated 316L SS10.1007/s10853-014-8425-7 ↗
27. Antibacterial copper-nickel bilayers and multilayer coatings by pulsed laser deposition on titanium10.1080/08927010903132183 ↗
28. Antimicrobial activity of zirconia (ZrO2) nanoparticles and zirconium complexes10.1166/jnn.2012.6574 ↗
29. Antibacterial effects of silver–zirconia composite coatings using pulsed laser deposition onto 316L SS for bio implants10.1007/s40204-014-0028-5 ↗
30. Seven-year prospective clinical study on zirconia-based single crowns and fixed dental prostheses10.1007/s00784-014-1330-2 ↗
31. Ag nanoparticle–coated zirconia for antibacterial prosthesis10.1016/j.msec.2017.04.149 ↗
32. Bio-inspired YSZ coated titanium by EBPVD for biomedical applications10.1016/j.surfcoat.2016.08.039 ↗
33. Phase diagram for a nano-yttria-stabilized zirconia system10.1039/C5RA24330K ↗
34. In vitro corrosion and biocompatibility screening of sputtered Ti40Cu36Pd14Zr10 thin film metallic glasses on steels10.1016/j.msec.2014.11.013 ↗
35. Fatigue and fracture properties of yttria partially stabilized zirconia crown systems10.1016/j.dental.2007.05.011 ↗