journal article·2019-05

Effect of aggregate size and inclusion of polypropylene and steel fibers on explosive spalling and pore pressure in ultra-high-performance concrete (UHPC) at elevated temperature

Ye Li, Pierre Pimienta, Nicolas Pinoteau, Kang Hai Tan

Publisher page

Abstract

Abstract This paper investigates the individual and combined effects of polypropylene (PP) fibers, steel fibers, and aggregate size on spalling behavior and pore pressure build-up of ultra-high-performance concrete (UHPC) exposed to elevated temperature. Simultaneous measurements of pore pressure and temperature were conducted at different depths in UHPC specimens under one-sided heating with a heating rate of 2 °C/min. Compressive, tensile, and permeability tests were performed to analyze spalling behavior. Addition of PP fibers fully prevented spalling and they are much more effective in increasing permeability than steel fibers and larger aggregates. The combined use of PP and steel fibers, and PP fibers and larger aggregates showed strong synergistic effect on increasing permeability. The higher the permeability, the lower was the maximum pore pressure measured in the samples. Two plateaus were observed from the temperature history due to vaporization of liquid water (between 115 and 125 °C inside the specimens) and release of water vapor (starting from 180 °C), respectively. The second plateau was identified as the functional temperature of PP fibers. Maximum pore pressures in spalled specimens were much lower than their tensile strengths, which could imply the contribution of hydraulic pressure in the region of moisture clog on spalling.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Innovative concrete reinforcement materials · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Temperature, pore pressure and mass variation of concrete subjected to high temperature — experimental and numerical discussion on spalling risk10.1016/j.cemconres.2009.10.011 ↗
2. Klingsch · 2014
3. Critical factors governing the fire performance of high strength concrete systems10.1016/j.firesaf.2006.10.006 ↗
4. Mechanical properties of concrete at high temperature—a review10.1016/j.conbuildmat.2015.05.131 ↗
5. Effect of damage on permeability and hygro-thermal behaviour of HPCs at elevated temperatures: Part 1. Experimental results10.12989/cac.2005.2.3.189 ↗
6. A review on ultra high performance concrete: Part II. Hydration, microstructure and properties10.1016/j.conbuildmat.2015.08.095 ↗
7. A review on ultra high performance concrete: Part I. Raw materials and mixture design10.1016/j.conbuildmat.2015.10.088 ↗
8. Influence of aggregate and curing regime on the mechanical properties of ultra-high performance fibre reinforced concrete (UHPFRC)10.1016/j.conbuildmat.2008.11.012 ↗
9. Ultra-high-performance concrete: research, development and application in Europe
10. First recommendations for ultra-high-performance concretes and examples of application
11. Heavy reinforced ultra high performance concrete
12. Structural rehabilitations with ultra high performance fibre reinforced concretes
13. Spalling in high strength concrete exposed to fire—concerns, causes, critical parameters and cures
14. Pore pressure development in hybrid fibre-reinforced high strength concrete at elevated temperatures10.1016/j.cemconres.2011.07.001 ↗
15. 2016
16. Influence of different fibers on the change of pore pressure of self-consolidating concrete exposed to fire10.1016/j.conbuildmat.2016.03.070 ↗
17. Effect of fibre type and geometry on maximum pore pressures in fibre-reinforced high strength concrete at elevated temperatures10.1016/j.cemconres.2011.11.014 ↗
18. Explosive spalling and residual mechanical properties of fiber-toughened high-performance concrete subjected to high temperatures10.1016/j.cemconres.2005.12.014 ↗
19. Effect of strength and fiber reinforcement on fire resistance of high-strength concrete columns10.1061/(ASCE)0733-9445(2003)129:2(253) ↗
20. Effect of fire on concrete and concrete structures10.1002/pse.51 ↗
21. Relationship between inter-aggregate spacing and the optimum fiber length for spalling protection of concrete in fire10.1016/j.cemconres.2011.12.002 ↗
22. Fibers, percolation, and spalling of high-performance concrete
23. Preparation of ultra-high performance concrete with common technology and materials10.1016/j.cemconcomp.2011.11.005 ↗
24. Hertz · 1984
25. Danish investigations on silica fume concretes at elevated temperatures
26. Modelling of heated concrete10.1680/macr.2002.54.2.77 ↗
27. Effects of various fibres on high-temperature spalling in high-performance concrete10.1016/j.conbuildmat.2014.07.068 ↗
28. Spalling and pore pressure in HPC at high temperatures10.1016/S0008-8846(00)00384-7 ↗
29. The determination of the permeability of concrete to oxygen by the Cembureau method—a recommendation10.1007/BF02472192 ↗
30. Permeability and pore structure evolution of silicocalcareous and hematite high-strength concretes submitted to high temperatures10.1007/BF02482129 ↗
31. Gas transport mode criteria in ultra-tight porous media10.1016/j.ijheatmasstransfer.2014.11.075 ↗
32. The permeability of porous media to liquids and gases
33. High-temperature behaviour of HPC with polypropylene fibres: from spalling to microstructure10.1016/S0008-8846(01)00596-8 ↗
34. Tests on the hot and residual permeability of concrete at high temperatures
35. Size effect on compressive strength of reactive powder concrete10.1016/S1006-1266(08)60059-0 ↗
36. Mechanical properties of ultra-high-performance fiber-reinforced concrete: a review10.1016/j.cemconcomp.2016.08.001 ↗
37. Mater · 2011
38. Hybrid short fiber reinforcement system in concrete: a review10.1016/j.conbuildmat.2017.03.059 ↗
39. Exploring mechanical and durability properties of ultra-high performance concrete incorporating various steel fiber lengths and dosages10.1016/j.conbuildmat.2014.11.017 ↗
40. Ultra-high performance concrete and fiber reinforced concrete: achieving strength and ductility without heat curing10.1617/s11527-011-9767-0 ↗
41. Influence of aggregate size and inclusion of polypropylene and steel fibers on the hot permeability of ultra-high performance concrete (UHPC) at elevated temperature10.1016/j.conbuildmat.2018.01.105 ↗
42. On the mechanism of prevention of explosive spalling in ultra-high performance concrete with polymer fibers10.1016/j.cemconres.2018.08.012 ↗
43. Influence of the interfacial transition zone and microcracking on the diffusivity, permeability and sorptivity of cement-based materials after drying10.1680/macr.2008.61.8.571 ↗
44. The effect of hybrid fibers and expansive agent on the shrinkage and permeability of high-performance concrete10.1016/S0008-8846(00)00479-8 ↗
45. Bažant · 1996
46. Simulating the effect of microcracks on the diffusivity and permeability of concrete using a three-dimensional model10.1016/j.commatsci.2016.03.047 ↗
47. 1995
48. A new test method to study the influence of pore pressure on fracture behaviour of concrete during heating10.1016/j.cemconres.2017.01.002 ↗
49. The effect of undrained heating on a fluid-saturated hardened cement paste10.1016/j.cemconres.2008.09.004 ↗
50. Heat-and moisture transport during drying and first heating of heat resistant concrete
51. Limits of spalling of fire-exposed concrete10.1016/S0379-7112(02)00051-6 ↗
52. Study of mechanisms of explosive spalling in high-strength concrete at high temperatures using acoustic emission10.1016/j.conbuildmat.2012.06.070 ↗
53. Behavior of ring-restrained high-performance concrete under extreme heating and development of screening test10.1016/j.conbuildmat.2017.11.144 ↗
54. On the influence of aggregate nature on concrete behaviour at high temperature10.1080/19648189.2012.667682 ↗
55. Experimental discussion on the mechanisms behind the fire spalling of concrete10.1002/fam.2254 ↗