Abstract
Although real-time quantitative polymerase chain reaction (real-time qPCR) is the gold standard for molecular diagnostics, prolonged thermal cycling constrains its rapid application. Here, we report an ultrafast real-time qPCR system utilizing dynamic water-flow thermal regulation. By integrating a flexible thin-film carrier with dynamic water flow, the system minimizes interfacial thermal resistance. Additionally, a feedforward predictive control algorithm enables precise temperature control using low-cost solenoid valves. Consequently, the system completes 45 cycles in under 10 min, with heating and cooling ramps of ∼3.7 and ∼0.7 s, respectively. In Mycoplasma pneumoniae validation, the device exhibits superior performance, achieving 10 copies/μL sensitivity, 96.8% efficiency, and R 2 > 0.99 linearity. This work integrates speed, precision, and low cost, demonstrating significant promise for point-of-care diagnostics and large-scale genetic screening.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Molecular Biology Techniques and Applications · Innovative Microfluidic and Catalytic Techniques Innovation · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Enzymatic amplification of β-globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia10.1126/science.2999980 ↗
2. Detection of specific polymerase chain reaction product by utilizing the 5′----3′exonuclease activity of Thermus aquaticus DNA polymerase10.1073/pnas.88.16.7276 ↗
3. Simultaneous amplification and detection of specific DNA sequences10.1038/nbt0492-413 ↗
4. A pneumonia outbreak associated with a new coronavirus of probable bat origin10.1038/s41586-020-2012-7 ↗
5. Comparison of the rapid antigen testing method with RT-qPCR for the diagnosis of COVID-19
6. Direct-RT-qPCR detection of SARS-CoV-2 without RNA extraction as part of a COVID-19 testing strategy: from sample to result in one hour10.3390/diagnostics10080605 ↗
7. PfAgo-based detection of SARS-CoV-2
8. Progress in molecular detection with high-speed nucleic acids thermocyclers10.1016/j.jpba.2020.113489 ↗
9. SF-qPCR: strand displacement-based fast quantitative polymerase chain reaction10.1007/s13206-021-00044-x ↗
10. In vitro diagnostics of coronavirus disease 2019: Technologies and application10.1016/j.jmii.2020.05.016 ↗
11. Polymerase chain reaction (PCR): Principle and applications
12. Multiplex real-time PCR assay to detect illegal trade of CITES-listed shark species10.1038/s41598-018-34663-6 ↗
13. Multiplex sample-to-answer detection of bacteria using a pipette-actuated capillary array comb with integrated DNA extraction, isothermal amplification, and smartphone detection10.1039/C8LC00543E ↗
14. A Thermocycler using a chip resistor heater and a glass microchip for a portable and rapid microchip-based PCR device10.3390/mi13020339 ↗
15. Disposable DNA amplification chips with integrated low-cost heaters10.3390/mi11030238 ↗
16. Rapid real-time PCR and high resolution melt analysis in a self-filling thermoplastic chip10.1039/C6LC00711B ↗
17. A highly integrated digital PCR system with on-chip heating for accurate DNA quantitative analysis10.1016/j.bios.2024.116167 ↗
18. Water-cooling-based and low-cost qPCR device for rapid nucleic acid analysis10.1016/j.sna.2024.115496 ↗
19. A novel microfluidic device integrated with chitosan-modified capillaries for rapid ZIKV detection10.3390/mi11020186 ↗
20. Ultrafast real-time pcr in photothermal microparticles10.1021/acsnano.2c07017 ↗
21. Nanocomposite-based PCR reactors to enhance thermal rate and fluorescence intensity in hand-held qPCR device10.1186/s12951-025-03287-0 ↗
22. Ultrafast plasmonic nucleic acid amplification and real-time quantification for decentralized molecular diagnostics10.1021/acsnano.2c11831 ↗
23. Plasmonic colorimetric PCR for Rapid molecular diagnostic assays10.1016/j.snb.2021.129762 ↗
24. Rapid membrane-based photothermal PCR for disease detection10.1016/j.snb.2022.131554 ↗
25. Plasmonic photothermal gold bipyramid nanoreactors for ultrafast real-time bioassays10.1021/jacs.7b01779 ↗
26. Ultrasensitive plasmonic photothermal immunomagnetic bioassay using real-time and end-point dual-readout10.1016/j.snb.2022.133110 ↗
27. Microfluidic diagnostic technologies for global public health10.1038/nature05064 ↗
28. Lab-on-a-chip devices for global health: Past studies and future opportunities10.1039/B611455E ↗
29. Leveraging Africa's preparedness towards the next phase of the COVID-19 pandemic10.1016/S2214-109X(20)30234-5 ↗
30. A low-cost and hand-hold PCR microdevice based on water-cooling technology10.1007/s10544-023-00652-4 ↗
31. A reverse design method for convective PCR chips featuring precise control of steady-state flow fields10.3390/chemosensors13010006 ↗
32. Highly multiplexed rapid DNA detection with single-nucleotide specificity via convective PCR in a portable device10.1038/s41551-021-00755-4 ↗
33. A rapid SARS-CoV-2 RT-PCR assay for low resource settings10.3390/diagnostics10100739 ↗
34. Inhibitory effect of common microfluidic materials on PCR outcome10.1016/j.snb.2011.10.044 ↗
35. Shunting microfluidic PCR device for rapid bacterial detection10.1016/j.talanta.2019.120303 ↗
36. Bestimmung der Absorption des rothen Lichts in farbigen Flüssigkeiten10.1002/andp.18521620505 ↗
37. Lehrbuch der ingenieur-und maschinen-mechanik
38. Empirical Relation between Hazen-Williams and Darcy-Weisbach Equations for Cold and Hot Water Flow in Plastic Pipes
39. Cant · 2001 · 125 · 1361
40. Comparison of time-resolved heat transfer characteristics between laminar and turbulent convection with unsteady flow temperatures10.1016/j.ijheatmasstransfer.2015.01.034 ↗
41. Incropera · 1990 · 1072
42. Shah · 2003
43. Bejan · 2013
44. PID temperature control system-based microfluidic PCR chip for genetic analysis10.1007/s42835-021-00969-1 ↗
45. Temperature control algorithm for polymerase chain reaction (PCR) instrumentation based upon improved hybrid fuzzy proportional integral derivative (PID) control10.1080/10739149.2022.2105866 ↗
46. Open thermal control system for stable polymerase chain reaction on a digital microfluidic chip10.1021/acsomega.3c10312 ↗
47. Construction of Very Low-Cost Loop Polymerase Chain Reaction System Based on Proportional-Integral-Derivative Temperature Control Optimization Algorithm and Its Application in Gene Detection10.1021/acsomega.2c02975 ↗
48. Mycoplasma pneumoniae P1 type 1-and type 2-specific sequences within the P1 cytadhesin gene of individual strains10.1128/IAI.69.9.5612-5618.2001 ↗
49. Characterisation of subtype-and variant-specific antigen regions of the P1 adhesin of Mycoplasma pneumoniae10.1016/j.ijmm.2007.06.002 ↗