journal article·2024-07Open access

Towards quantifying the air leakage through cross-laminated timber

Noel Cochon, Russell Richman

Abstract

This study aims to contribute to limited research evidence for evaluating air leakage through Canadian manufactured CLT, by initiating research to characterize and quantify air leakage paths across CLT panels and evaluate the impact of additional air barrier system components on CLT. Understanding air leakage across CLT is important to the continuous development of design and construction practices towards ensuring the performance of CLT buildings. Through experimental testing of various panel parameters, metrics including the air leakage rate, normalized equivalent leakage area, as well as the flow exponent and flow coefficient were measured. For 3-ply and 5-ply CLT panels utilized in this research, significant air leakage through panel edges compared to air leakage through the panel face was observed due to unglued edge joint gaps typical to Canadian manufactured CLT. Further, sealing panel edges with an effective air barrier material such as a self-adhered membrane to reduce air leakage from 4 - 12 L/sm2 to 0.09 - 1.4 L/sm2 was not enough to meet more stringent thresholds for air barrier assemblies at 0.1 L/sm2 at a 75 Pa pressure differential.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Analysis of Composite Materials · Structural Engineering and Vibration Analysis · Wind and Air Flow Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. AlSayegh, G. (2012). Hygrothermal Properties of Cross Laminated Timber and Moisture Response of Wood at High Relative Humidity. Library and Archives Canada.
2. American Society for Testing and Materials (ASTM). (2017, October 3). ASTM E779 – 10 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization. American Society for Testing and Materials.
3. APA – The Engineered Wood Association. (2019). ANSI/APA PRG 320–2019 Standard for Performance-Rated Cross-Laminated Timber. APA – The Engineered Wood Association.
4. CGSB (Canadian General Standards Board). (2013). 149.10-M86 Determination of the Airtightness of Building Envelopes by the Fan Depressurization Method.
5. Elnaffar, A. (2020). A Methodological Approach to Predict and Estimate Air Leakage Through a Window-to-Wall Interface in Wood Frame Construction.
6. Stora Enso. (2021). CLT by Stora Enso, Technical Brochure. Stora Enso. 〈https://www.storaenso.com/-/media/documents/download-center/documents/product-brochures/wood-products/clt-by-stora-enso-technical-brochure-en.pdf〉.
7. FPInnovations. (2019). Canadian CLT Handbook, 2019 Edition, Volume 1. FPInnovations.
8. Henry Company Canada. Aqua-Bloc 720–38 Technical Data Sheet. Henry Company Canada, 〈https://ca.henry.com/fileadmin/pdf/current/tds/BK72038_techdata.pdf〉 Accessed 7 June 2021.
9. Hutcheon, N., Handegord, G. (1995). Building Science for a Cold Climate. National Research Council of Canada.
10. Case studies of building envelope leakage measurement using an air-handler fan pressurization approach10.1177/0143624407088049 ↗
11. Air leakage levels in timber frame building envelope joints10.1016/j.buildenv.2017.02.011 ↗
12. A univariate and multiple linear regression analysis on a national fan (de)Pressurization testing database to predict airtightness in houses10.1016/j.buildenv.2018.09.030 ↗
13. Towards a methodological approach to builder specific, preconstruction airtightness estimates for light-framed, detached, low-rise residential buildings in Canada
14. The effects of production technologies on the air permeability and crack development of cross-laminated timber
15. National Research Council of Canada (NRC). (2014, December 31). Report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings. National Research Council of Canada.
16. SIGLENT. (2021). “SDM3055”. SIGLENT Technologies, 〈https://siglentna.com/product/sdm3055/〉 Accessed 6 August 2021.
17. Skogstad, H. et. al. (2011). Air Leakages Through Cross-Laminated Timber (CLT) Constructions. SINTEF Building and Infrastructure.
18. Wood based building envelope regarding air tightness10.4028/www.scientific.net/KEM.688.160 ↗
19. Straube, J. (2007, October 15). Air Flow Control in Buildings. Building Science Press. 〈https://www.buildingscience.com/file/5683/download?token=bLng1j_n〉.
20. Technical University of Graz. (2014). Air Permeability Test on a Test Object in Accordance with ÖNORM EN 1026 and ÖNORM EN 12114. Technical University of Graz.
21. The Energy Conservatory. (2021). “DG-100 Overview Booklet”. The Energy Conservatory, 〈https://energyconservatory.com/support/dg-1000-overview-booklet/〉 Accessed 5 August 2021.
22. Tramex Ltd. “MEP – Moisture Encounter Plus User Guide”. Tramex Ltd, 〈https://tramexmeters.com/perch/resources/downloads/user-guides/mep-user-guide.pdf〉 Accessed 7 June 2021.
23. Tuck Tape. “Contractor’s Sheathing Tape for PE Vapor Barrier”. Tuck Tape, 〈http://specs.safetyexpress.com/219–08%20SpecDocument-EN.pdf〉 Accessed 7 June 2021.
24. The effect of an enclosure retrofit on air leakage rates for a multi-unit residential case-study building10.1016/j.enbuild.2014.09.079 ↗
25. Waite, M., O’Brien, S. (2010). Air Leakage: Difficulties in Measurement, Quantification, and Energy Simulation. 〈https://c.ymcdn.com/sites/www.nibs.org/resource/resmgr/BEST/BEST2_018_WB6–1.pdf〉.
26. Air infiltration through building envelopes: a review10.1177/1744259111423085 ↗