Seismic behaviour of self-centring hybrid steel frames equipped with SMA plates under mainshock–aftershock sequences
Source abstract
Abstract
This paper focuses on the mechanical behaviour, seismic application in steel frame connections and steel structure of shape memory alloy (SMA) plates. This study commenced by examining the hysteretic response of SMA plates subjected to cyclic tension tests, considering two different loading paths. Subsequently, a self-centring steel frame connection equipped with SMA plates and washers (SC-PW) was examined via quasi-static cyclic loading tests, and comparatively satisfactory self-centring behaviour was observed. However, the degradation of the initial stiffness of the SC-PW due to an initial imperfection was observed. An improvement strategy was proposed to overcome the degradation of the hysteretic behaviour (e.g., initial stiffness) of the SC-PW. Disc springs with a larger stiffness and preloads were introduced to overcome the degradation of the initial stiffness of the SC-PW, and the validation was confirmed via detailed finite element (FE) analyses. To improve the computation efficiency, a simplified FE model was developed to reproduce the hysteretic responses of the connection. Based on the simplified FE model, a six-storey prototype structure, i.e., a self-centring hybrid steel frame (SCHSF), equipped with the improved connection was developed, and the structural dynamic responses were investigated via nonlinear response history analyses, where mainshock–aftershock sequences were considered. The influence of the SMA material properties on the seismic behaviour of the prototype structure was investigated.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Seismic Performance and Analysis · Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (62)
Show source-provided references
1. Damage to steel buildings observed after the 2011 Tohoku-Oki earthquake10.1193/1.4000124 ↗
2. Permissible residual deformation levels for building structures considering both safety and human elements
3. Residual drift response of SMRFs and BRB frames in steel buildings designed according to ASCE 7-0510.1061/(ASCE)ST.1943-541X.0000296 ↗
4. Tests, numerical simulations and design of G550 high strength cold-formed steel lipped channel section columns failing by interactive buckling10.1016/j.tws.2023.111172 ↗
5. Testing, numerical modelling and design of S890 and S960 ultra-high strength steel circular hollow sections under combined loading10.1016/j.tws.2023.111102 ↗
6. Structural performance and design of S960 ultra-high strength steel non-slender welded I-sections subjected to combined loading10.1016/j.engstruct.2023.116593 ↗
7. Strain-rate and stress-state dependent ductile fracture model of S690 high-strength steel10.1016/j.jcsr.2023.107852 ↗
8. Post–fire properties of stainless–clad bimetallic steel produced by explosive welding process10.1016/j.jcsr.2022.107690 ↗
9. Experimental and numerical investigations of S960 ultra-high strength steel welded I-section beams with in-plane flexural failure10.1016/j.tws.2023.110969 ↗
10. Nonlinear patch resistance performance of hybrid titanium-clad bimetallic steel plate girder with web opening
11. Mechanical properties and microstructure characteristics of wire arc additively manufactured high-strength steels10.1016/j.engstruct.2023.117092 ↗
12. Mechanical behavior of austenitic stainless steels produced by wire arc additive manufacturing10.1016/j.tws.2023.111455 ↗
13. Structural behaviour of cold-formed steel elliptical hollow section stub columns after exposure to ISO-834 fire curve
14. Experimental investigation of a high strength steel frame with curved knee braces subjected to extreme earthquakes10.1016/j.tws.2023.110596 ↗
15. Experimental and numerical study of a brace-type hybrid damper with steel slit plates enhanced by friction mechanism10.1016/j.tws.2022.110249 ↗
16. Life-cycle benefits estimation of self-centering building structures10.1016/j.engstruct.2023.115982 ↗
17. Parametric topology optimization design and analysis of additively manufactured joints in spatial grid structures10.1016/j.engstruct.2023.117123 ↗
18. Steel beam-column connections using shape memory alloys10.1061/(ASCE)0733-9445(2004)130:5(732) ↗
19. Feasibility study on a self-centering beam-to-column connection by using the superelastic behavior of SMAs, Smart
20. Experimental results of a NiTi shape memory alloy (SMA)-based recentering beam-column connection10.1016/j.engstruct.2011.04.018 ↗
21. Seismic response of steel braced frames with shape memory alloy braces10.1016/j.jcsr.2010.06.006 ↗
22. Self-centering beam-to-column connections with combined superelastic SMA bolts and steel angles10.1061/(ASCE)ST.1943-541X.0001675 ↗
23. A study of hybrid self-centring connections equipped with shape memory alloy washers and bolts10.1016/j.engstruct.2018.03.006 ↗
24. Surrogate models for endplate beam-column connections with shape memory alloy bolts10.1016/j.jcsr.2021.106929 ↗
25. Self-centring damper with multi-energy-dissipation mechanisms: Insights and structural seismic demand perspective10.1016/j.jcsr.2023.107837 ↗
26. Cyclic performance of extended end-plate connections equipped with shape memory alloy bolts10.1016/j.jcsr.2013.11.008 ↗
27. Experimental study of new axial recentering dampers equipped with shape memory alloy plates10.1002/stc.2680 ↗
28. Shape memory alloy plates: Cyclic tension-release performance, seismic applications in beam-to-column connections and a structural seismic demand perspective10.1016/j.tws.2021.108158 ↗
29. Large-size shape memory alloy plates subjected to cyclic tension: Towards novel self-centring connections in steel frames10.1016/j.tws.2023.110591 ↗
30. Superelastic SMA U-shaped dampers with self-centering functions10.1088/1361-665X/aab52d ↗
31. Vision-based support in the characterization of superelastic U-shaped SMA elements
32. Experimental study of novel self-centering seismic base isolators incorporating superelastic shape memory alloys10.1061/(ASCE)ST.1943-541X.0002679 ↗
33. Development of superelastic SMA angles as seismic-resistant self-centering devices10.1016/j.engstruct.2020.110836 ↗
34. Feasibility study of utilizing superelastic shape memory alloy plates in steel beam–column connections for improved seismic performance10.1177/1045389X14529032 ↗
35. A study of hybrid self-centring beam-to-beam connections equipped with shape-memory-alloy-plates and washers10.1016/j.jcsr.2022.107526 ↗
36. A probabilistic framework for estimating the residual drift of idealized SDOF systems of non‐degrading conventional and damped structures10.1002/eqe.2975 ↗
37. Superelastic SMA Belleville washers for seismic resisting applications: experimental study and modelling strategy, Smart
38. Variable-friction self-centering energy-dissipation braces (VF-SCEDBs) with NiTi SMA cables for seismic resilience10.1016/j.jcsr.2020.106318 ↗
39. Analytical and numerical study on the cyclic behavior of buckling-restrained SMA-based self-centering damper, Smart
40. Fromm · 2003
41. GBT1972–2005, Disc spring, Standards Press of China, Beijing, China, 2005.
42. A robust integration-algorithm for a finite-strain shape-memory-alloy superelastic model10.1016/S0749-6419(00)00050-4 ↗
43. GB 50017–2017, Standard for design of steel structures, Chinese Building Press, Beijing, China, 2018.
44. High-mode effects on seismic performance of multi-story self-centering braced steel frames10.1016/j.jcsr.2015.12.008 ↗
45. Peak and residual responses of steel moment-resisting and braced frames under pulse-like near-fault earthquakes10.1016/j.engstruct.2018.10.013 ↗
46. Self-centring hybrid-steel-frames employing energy dissipation sequences: Insights and inelastic seismic demand model
47. GB 50011–2016, Code for seismic design of buildings, Chinese Building Press, Beijing, China, 2016.
48. GB 50009–2012, Load code for design of buildings, Chinese Building Press, Beijing, China, 2012.
49. Seismic performance of MRFs with high strength steel main frames and EDBs10.1016/j.jcsr.2016.07.003 ↗
50. Chopra · 2017
51. Seismic upgrading of multistory steel moment-resisting frames by installing shape memory alloy braces: design method and performance evaluation10.1002/stc.2596 ↗
52. Experimental response of buildings designed with metallic structural fuses. II10.1061/(ASCE)0733-9445(2009)135:4(394) ↗
53. Seismic demand amplification of steel frames with SMAs induced by earthquake sequences10.1016/j.jcsr.2023.107929 ↗
54. NGA-West2 Database10.1193/070913EQS197M ↗
55. ASCE, Minimum design loads for buildings and other structures, VA: ASCE/SEI 7–10, Reston, 2010.
56. Seismic risk of base isolated non-ductile reinforced concrete buildings considering uncertainties and mainshock–aftershock sequences10.1016/j.strusafe.2014.03.010 ↗
57. Seismic evaluation of steel moment frames under mainshock–aftershock sequence designed by elastic design and PBPD methods10.1080/13632469.2017.1387198 ↗
58. Comparative study on seismic fragility assessment of self-centering energy-absorbing dual rocking core versus buckling restrained braced systems under mainshock–aftershock sequences10.1061/(ASCE)ST.1943-541X.0003082 ↗
59. SAC Joint Venture, FEMA-356. Prestandard and commentary for the seismic rehabilitation of buildings, Federal Emergency Management Agency, Washington, D.C, 2000.
60. Modified direct displacement‐based design approach for structures equipped with fluid viscous damper10.1002/stc.2465 ↗
61. Aftershock seismic assessment taking into account postmainshock residual drifts: aftershock seismic assessment including postmainshock residual drifts10.1002/eqe.2523 ↗
62. A procedure for generating performance spectra for structures equipped with passive supplemental dampers: generating of performance spectra for structures with passive dampers10.1002/eqe.2274 ↗